The newly developed radioisotope-free technique based on magnetic nanoparticle detection using a magnetic probe is a promising method for sentinel lymph node biopsy. In this study, a novel handheld magnetic probe with a permanent magnet and magnetic sensor is developed to detect the sentinel lymph nodes in breast cancer patients. An outstanding feature of the probe is the precise positioning of the sensor at the magnetic null point of the magnet, leading to highly sensitive measurements unaffected by the strong ambient magnetic fields of the magnet. Numerical and experimental results show that the longitudinal detection length is approximately 10 mm, for 140 μg of iron. Clinical tests were performed, for the first time, using magnetic and blue dye tracers—without radioisotopes—in breast cancer patients to demonstrate the performance of the probe. The nodes were identified through transcutaneous and ex-vivo measurements, and the iron accumulation in the nodes was quantitatively revealed. These results show that the handheld magnetic probe is useful in sentinel lymph node biopsy and that magnetic techniques are widely being accepted as future standard methods in medical institutions lacking nuclear medicine facilities.
We report a 2.45GHz microwave-excited atmospheric-pressure plasma jet (MW-APPJ) device using a microstrip line for materials processing. A three-dimensional simulation based on the finite difference time domain method revealed that the configuration of the MW-APPJ device results in a strong concentration of electric fields at the gas nozzle. Argon plasmas were generated at the nozzle and were blown into ambient air with the maximum length of 5mm at a microwave power of 40W. The rotational temperatures of molecular nitrogen in the downstream of the plasma jets, measured by optical emission spectroscopy, were 1720to900K for gas flow rates from 0.5to3.5l∕min, indicating that the jets were nonthermal plasmas. This MW-APPJ device will provide a large-area APPJ for materials processing depending on the configuration of the nozzle array and microstrip lines.
LiteBIRD is a candidate for JAXA s strategic large mission to observe the cosmic microwave background (CMB) polarization over the full sky at large angular scales. It is planned to be launched in the 2020s with an H3 launch vehicle for three years of observations at a Sun-Earth Lagrangian point (L2). The concept design has been studied by researchers from Japan, U.S., Canada and Europe during the ISAS Phase-A1. Large scale measurements of the CMB B-mode polarization are known as the best probe to detect primordial gravitational waves. The goal of LiteBIRD is to measure the tensor-to-scalar ratio (r) with precision of δr < 0.001. A 3-year full sky survey will be carried out with a low frequency (34-161 GHz) telescope (LFT) and a high frequency (89-448 GHz) telescope (HFT), which achieve a sensitivity of 2.5 µK-arcmin with an angular resolution of ∼ 30 arcminutes around 100 GHz. The concept design of LiteBIRD system, payload module (PLM), cryo-structure, LFT and verification plan is described in this paper.
BackgroundNeuroinflammation is associated with many conditions that lead to dementia, such as cerebrovascular disorders or Alzheimer’s disease. However, the specific role of neuroinflammation in the progression of cognitive deficits remains unclear. To understand the molecular mechanisms underlying these events we used a rodent model of focal cerebral stroke, which causes deficits in hippocampus-dependent cognitive function.MethodsCerebral stroke was induced by middle cerebral artery occlusion (MCAO). Hippocampus-dependent cognitive function was evaluated by a contextual fear conditioning test. The glial neuroinflammatory responses were investigated by immunohistochemical evaluation and diffusion tensor MRI (DTI). We used knockout mice for P2Y1 (P2Y1KO), a glial ADP/ATP receptor that induces the release of proinflammatory cytokines, to examine the links among P2Y1-mediated signaling, the neuroinflammatory response, and cognitive function.ResultsDeclines in cognitive function and glial neuroinflammatory response were observed after MCAO in both rats and mice. Changes in the hippocampal tissue were detected by DTI as the mean diffusivity (MD) value, which corresponded with the cognitive decline at 4 days, 1 week, 3 weeks, and 2 months after MCAO. Interestingly, the P2Y1KO mice with MCAO showed a decline in sensory-motor function, but not in cognition. Furthermore, the P2Y1KO mice showed neither a hippocampal glial neuroinflammatory response (as assessed by immunohistochemistry) nor a change in hippocampal MD value after MCAO. In addition, wild-type mice treated with a P2Y1-specific antagonist immediately after reperfusion did not show cognitive decline.ConclusionOur findings indicate that glial P2Y1 receptors are involved in the hippocampal inflammatory response. The findings from this study may contribute to the development of a therapeutic strategy for brain infarction, targeting the P2Y1 receptor.
We have studied the pulse field magnetization of a YBCO bulk superconducting ring. In the experiments a 6 ms pulse magnetic field was applied to a ring-shaped YBCO superconductor with a 46 mm outer diameter, 16 mm inner diameter and 15 mm height, which was cooled by liquid nitrogen (77 K). Then, trapped magnetic field profiles were measured with a Hall sensor. For example, a single 1.2 T pulse field generated a hollow profile of the trapped magnetic field. In addition, the finite element method was used to solve the coupled problem of thermal and electromagnetic fields, where the power-n model was adopted for the E-J (E is the electric field and J is the current density) relation in the superconductor. A comparison between the results of experiment and analysis has shown that n = 6 gave good agreement between them. We have also discussed the current density distribution, temperature distribution, etc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.