Hermetic packaging is a critical requirement for microbolometers to maintain long-term reliability. A thinner diaphragm is desirable for vacuum packaging of microbolometers to obtain higher infrared light transmission. However, a thinner diaphragm results in a larger deflection due to the pressure difference from atmosphere, which may influence the IR signal focus and possibly cause mechanical failure. In this paper, the trade-offs of using thin single crystal silicon diaphragms as encapsulation for hermetic packaging of microbolometer arrays have been investigated in terms of the mechanical stability and optical performance using COMSOL and Zemax. The optical simulations show that the bending of the thin diaphragm has negligible effect on the infrared light focus with wavelengths from 8 to 14 µm. The mechanical simulations reveal that a thin diaphragm (thickness < 70 µm) with 10×10 mm 2 area and a diaphragm (thickness < 90 µm) with 12×12 mm 2 area will cause mechanical failure, and the designed diaphragm thickness must incorporate margins to these values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.