Cranioplasty (CP) is a standard procedure in neurosurgical practice for patients after (decompressive) craniectomy. However, CP surgery is not standardized, is carried out in different ways, and is associated with considerable complication rates. Here, we report our experiences with the use of different CP materials and analyze long-term complications and implant survival rates. We retrospectively studied patients who underwent CP surgery at our institution between 2004 and 2014. Binary logistic regression analysis was performed in order to identify risk factors for the development of complications. Kaplan-Meier analysis was used to estimate implant survival rates. A total of 392 patients (182 females, 210 males) with a mean age of 48 years were included. These patients underwent a total of 508 CP surgeries. The overall complication rate of primary CP was 33.2%, due to bone resorption/ loosening (14.6%) and graft infection (7.9%) with a mean implant survival of 120 ± 5 months. Binary logistic regression analysis showed that young age (< 30 years) (p = 0.026, OR 3.150), the presence of multidrug-resistant bacteria (p = 0.045, OR 2.273), and cerebrospinal fluid (CSF) shunt (p = 0.001, OR 3.137) were risk factors for postoperative complications. The use of titanium miniplates for CP fixation was associated with reduced complication rates and bone flap osteolysis as well as longer implant survival rates. The present study highlights the risk profile of CP surgery. Young age (< 30 years) and shunt-dependent hydrocephalus are associated with postoperative complications especially due to bone flap autolysis. Furthermore, a rigid CP fixation seems to play a crucial role in reducing complication rates.
OBJECTIVECraniopharyngiomas are rare and benign tumors of the sellar and/or parasellar region. Primary treatment involves resection followed by adjuvant radiotherapy. While the grade of resection was frequently analyzed following surgery, the neurological outcome and especially neuropsychological deficits and quality of life have been neglected for many decades. Therefore, the authors retrospectively analyzed their patient series and prospectively assessed neuropsychological outcome and quality of life following resection of craniopharyngiomas in adults.METHODSIn total, 71 patients (39 men and 32 women) with a mean age of 49 years were enrolled in the retrospective analysis. In addition, 36 of the 71 patients were included in the prospective arm of the study and underwent neurological and neuropsychological testing as well as quality of life (36-Item Short-Form Health Survey; SF-36) assessment. Factors influencing outcome were identified and correlations calculated.RESULTSResection was performed mostly using a pterional (41.6%, 47/113 surgical procedures) or bifrontal translamina terminalis (30.1%, 34/113 surgical procedures) approach. Following surgery, visual acuity was significantly improved (> 0.2 diopters) in 32.4% (23/71) of patients, or remained stable in 45.1% (32/71) of patients. During long-term follow up, 80.3% (57/71) of patients developed pituitary insufficiency, particularly involving the corticotropic and thyrotrophic axes. In total, 75% (27/36) of patients showed neuropsychological deviations in at least 1 test item. In particular, attentiveness, cognitive speed, and short-term memory were affected. Referring to the SF-36 score, quality of life was affected in both the mental and physical score in 19.4% (7/36) and 33.3% (12/36), respectively. The risk factors that were identified were a tumor volume larger than 9 cm3, tumor extension toward/into the third ventricle or the brainstem, and resection using a bifrontal translamina terminalis or left-sided approach.CONCLUSIONSThis study demonstrated that resection of craniopharyngiomas is frequently associated with postoperative neuropsychological deficits and hence an impaired quality of life. In addition to tumor size and extension toward/into the third ventricle or the brainstem, selection of the surgical approach may play a crucial role in the patient’s neuropsychological outcome and quality of life.
Background: Magnetic resonance imaging (MRI) is replacing computed tomography (CT) as the main imaging modality for stereotactic transformations. MRI is prone to spatial distortion artifacts, which can lead to inaccuracy in stereotactic procedures. Objective: Modern MRI systems provide distortion correction algorithms that may ameliorate this problem. This study investigates the different options of distortion correction using standard 1.5-, 3- and 7-tesla MRI scanners. Methods: A phantom was mounted on a stereotactic frame. One CT scan and three MRI scans were performed. At all three field strengths, two 3-dimensional sequences, volumetric interpolated breath-hold examination (VIBE) and magnetization-prepared rapid acquisition with gradient echo, were acquired, and automatic distortion correction was performed. Global stereotactic transformation of all 13 datasets was performed and two stereotactic planning workflows (MRI only vs. CT/MR image fusion) were subsequently analysed. Results: Distortion correction on the 1.5- and 3-tesla scanners caused a considerable reduction in positional error. The effect was more pronounced when using the VIBE sequences. By using co-registration (CT/MR image fusion), even a lower positional error could be obtained. In ultra-high-field (7 T) MR imaging, distortion correction introduced even higher errors. However, the accuracy of non-corrected 7-tesla sequences was comparable to CT/MR image fusion 3-tesla imaging. Conclusion: MRI distortion correction algorithms can reduce positional errors by up to 60%. For stereotactic applications of utmost precision, we recommend a co-registration to an additional CT dataset.
BACKGROUNDFreehand ventricular catheter placement may represent limited accuracy for the surgeon's intent to achieve primary optimal catheter position.OBJECTIVETo investigate the accuracy of a ventricular catheter guide assisted by a simple mobile health application (mhealth app) in a multicenter, randomized, controlled, simple blinded study (GAVCA study).METHODSIn total, 139 eligible patients were enrolled in 9 centers. Catheter placement was evaluated by 3 different components: number of ventricular cannulation attempts, a grading scale, and the anatomical position of the catheter tip. The primary endpoint was the rate of primary cannulation of grade I catheter position in the ipsilateral ventricle. The secondary endpoints were rate of intraventricular position of the catheter's perforations, early ventricular catheter failure, and complications.RESULTSThe primary endpoint was reached in 70% of the guided group vs 56.5% (freehand group; odds ratio 1.79, 95% confidence interval 0.89-3.61). The primary successful puncture rate was 100% vs 91.3% (P = .012). Catheter perforations were located completely inside the ventricle in 81.4% (guided group) and 65.2% (freehand group; odds ratio 2.34, 95% confidence interval 1.07-5.1). No differences occurred in early ventricular catheter failure, complication rate, duration of surgery, or hospital stay.CONCLUSIONThe guided ventricular catheter application proved to be a safe and simple method. The primary endpoint revealed a nonsignificant improvement of optimal catheter placement among the groups. Long-term follow-up is necessary in order to evaluate differences in catheter survival among shunted patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.