Gold nanoparticles (GNPs) are often used as colloidal carriers in numerous applications owing to their low-cost and size-controlled preparation as well as their straightforward surface functionalization with thiol containing molecules forming self-assembling monolayers (SAM). The quantification of the ligand density of such modified GNPs is technically challenging, yet of utmost importance for quality control in many applications. In this contribution, a new method for the determination of the surface coverage of GNPs with thiol containing ligands is proposed. It makes use of the measurement of the gold-to-sulfur (Au/S) ratio by inductively coupled plasma mass spectrometry (ICP–MS) and its dependence on the nanoparticle diameter. The simultaneous ICP–MS measurement of gold and sulfur was carefully validated and found to be a robust method with a relative standard uncertainty of lower than 10%. A major advantage of this method is the independence from sample preparation; for example, sample loss during the washing steps is not affecting the results. To demonstrate the utility of the straightforward method, GNPs of different diameters were synthesized and derivatized on the surface with bifunctional (lipophilic) ω-mercapto-alkanoic acids and (hydrophilic) mercapto-poly(ethylene glycol) (PEG)n-carboxylic acids, respectively, by self-assembling monolayer (SAM) formation. Thereby, a size-independent but ligand-chain length-dependent ligand density was found. The surface coverage increases from 4.3 to 6.3 molecules nm–2 with a decrease of ligand chain length from 3.52 to 0.68 nm. Furthermore, no significant difference between the surface coverage of hydrophilic and lipophilic ligands with approximately the same ligand length was found, indicating that sterical hindrance is of more importance than, for example, intermolecular strand interactions of Van der Waals forces as claimed in other studies.
Gold nanoparticles (GNPs) are popular colloidal substrates in various sensor, imaging, and nanomedicine applications. In separation science, they have raised some interest as a support for sample preparation. Reasons for their popularity are their low cost, ability for size-controlled synthesis with well-defined narrow nanoparticle size distributions, as well as straightforward surface functionalization by self-assembling (thiol-containing) molecules on the surface, which allows flexible introduction of functionalities for the selective capture of analytes. Most commonly, the method of first choice for size determination is dynamic light scattering (DLS). However, DLS has some serious shortcomings, and results from DLS may be misleading. For this reason, in this contribution several distinct complementary nanoparticle sizing methodologies were utilized and compared to characterize citrate-capped GNPs of different diameters in the range of 13-26 nm. Weaknesses and strengths of DLS, transmission electron microscopy, asymmetrical-flow field-flow fractionation and nanoelectrospray gas-phase electrophoretic mobility molecular analysis are discussed and the results comparatively assessed. Furthermore, the distinct GNPs were characterized by measuring their zeta-potential and surface plasmon resonance spectra. Overall, the combination of methods for GNP characterization gives a more realistic and comprehensive picture of their real physicochemical properties, (hydrodynamic) diameter, and size distribution.
Phosphorylated carbohydrates are important intracellular metabolites and thus of prime interest in metabolomics research. Complications in their analysis arise from the existence of structural isomers that do have similar fragmentation patterns in MS/MS and are hard to resolve chromatographically. Herein, we present selective methods for the liquid chromatographic separation of sugar phosphates, such as hexose and pentose phosphates, 2- and 3-phosphoglycerate, dihydroxyacetone phosphate and glyceraldehyde 3-phosphate, as well as glucosamine 1- and 6-phosphate utilizing mixed-mode chromatography with reversed-phase/weak anion-exchangers and a charged aerosol detector. The best results were obtained when the reversed-phase/weak anion-exchanger column was operated under hydrophilic interaction liquid chromatography elution conditions. The effects of various chromatographic parameters were examined and are discussed on the basis of a simple stoichiometric displacement model for explaining ion-exchange processes. Employed acidic conditions have led to the complete separation of α- and β-anomers of glucose 6-phosphate at low temperature. The anomers coeluted in a single peak at elevated temperatures (>40°C) (peak coalescence), while at intermediate temperatures on-column interconversion with a plateau in-between resolved anomer peaks was observed with apparent reaction rate constants between 0.1 and 27.8×10(-4) s(-1). Dynamic HPLC under specified conditions enabled to investigate mutarotation of phosphorylated carbohydrates, their interconversion kinetics, and energy barriers for interconversion. A complex mixture of six hexose phosphate structural isomers could be resolved almost completely.
Abstract-Lipidomics is the comprehensive analysis of molecular lipid species, including their quantitation and metabolic pathways. The huge diversity of native lipids and their modifications make lipidomic analyses challenging. The method of choice for sensitive detection and quantitation of molecular lipid species is mass spectrometry, either by direct infusion (shotgun lipidomics) or coupled with liquid chromatography. Although shotgun lipidomics allows for high-throughput analysis, low-abundant lipid species are not detected. Previous separation of lipid species by liquid chromatography increases ionization efficiency and is better suited for quantifying low abundant and isomeric lipid species. In this review, we will discuss the potential of lipidomics for cardiovascular research. To date, cardiovascular research predominantly focuses on the role of lipid classes rather than molecular entities. An in-depth knowledge about the molecular lipid species that contribute to the pathophysiology of cardiovascular diseases may provide better biomarkers and novel therapeutic targets for cardiovascular disease. (Circ Cardiovasc Genet. 2014;7:941-954.)
Oxidized low-density lipoproteins (OxLDLs), in particular, oxidized phosphatidylcholines (OxPCs), are known to be involved in pathophysiological processes such as cardiovascular diseases and are described as potential biomarkers, for example, for atherosclerosis. In our study, we used the specific affinity of anti-OxLDL antibodies (Abs) conjugated to gold nanoparticles (GNPs) for extraction and enrichment of OxPCs via selective trapping of OxLDLs from plasma combined with the sensitive detection by liquid chromatography/tandem-mass spectrometry (LC-MS/MS). Successful bioconjugation chemistry of Abs via a bifunctional polyethylene glycol (PEG) spacer and protein G linkage, respectively, was controlled by measuring the surface plasmon resonance (SPR) spectra, size, and zeta potentials. Furthermore, the amount of Ab immobilized onto GNP via the PEG linker was determined. With the optimized immobilization chemistry, the ability and potential of the GNP-based extraction procedure was used for the determination of the dissociation constant, K(d), of the OxLDL binding to the GNP-Ab conjugate. Moreover, apparent K(d)'s were determined for individual PCs and their oxidation products using the compound-specific selected reaction monitoring mode, which allows the characterization of the Ab affinity and, thus, assessment of the potential antigenicity of (Ox)PCs bound to OxLDLs. In summary, the application of GNP-based bioanalysis for selective targeting of OxLDLs and the fast and sensitive detection by LC-MS/MS offers new possibilities for targeted lipidomics in lipoproteins as well as for oxidative stress lipid biomarker screening.
The multiplexing capability of LC-MS combined with a standard-flow method increases throughput and reduces the costs of large-scale protein measurements in epidemiological cohorts, but protein rather than peptide standards will be required for defined absolute proteoform quantification.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.