A 3D numerical simulation was conducted to test the effects of the geometrical and operational parameters on the cooling performance of a three-phase electrical distribution transformer (250 kVA oil natural air natural (ONAN)). The geometric parameters include the shape of the transformer (rectangular, circular, and hexagonal), fins shape (rectangular, semicircular, and trapezoidal) as well it arrangement (asymmetric fin heights and perforated fins). Both of oil temperature and thermal load have been used as boundary conditions. In order to verify the reliability of the numerical model, comparison between numerical results and experimental finding has been done. The results have indicated that the circular and hexagonal shapes reduced the average oil temperature by 3.4% and 4.7%, respectively, compared to the traditional transformer shape (rectangular). Furthermore, the lowest average oil temperature was observed for the trapezoidal fin, followed by the rectangular and semicircular fins. Additionally, it has been noticed that the asymmetric fin heights of the trapezoidal and perforated trapezoidal fins been contributed to the improvement of the cooling performance of the transformer. Furthermore, the best thermal performance was obtained with the trapezoidal perforated fin to compared other arrangement of fins. Finally, the highest reduction in oil has been obtained by the use of hexagonal transformer with a perforated trapezoidal fin approximately by 12% compared to traditional rectangular transformer. Hence, it can be concluded that the shape of the transformer and fins play an important role in thermal performance of such systems.
The present study involves experimental and computational analysis to investigate the thermal performance of modified closed wet cooling tower in perspective of first and second law of thermodynamics (analysis of energy and exergy) according to Iraqi weather. The experimental study includes design, manufacture and testing prototype of a modified counter flow forced draft closed wet cooling tower. The modification based on addition packing to the conventional closed wet cooling tower. To assess the thermal performance of cooling towera progression of tests was done at various operational and conformational parameters.The theoretical study included developed six models by an Adaptive Neuro-Fuzzy Inference System to anticipating various execution parameters of the tower including the cooling range, tower approach, thermal efficiency, cooling capacity, evaporation losses and exergy destruction. After simulating, three dimensional surface viewers obtained for future behavior of the thermal performance of cooling tower involves interactions between all operational parameters. Comparison of the output values obtained using the Adaptive Neuro-Fuzzy Inference System model and those obtained experimentally for other cases not included in the training data, indicates high compatibility with maximum percentage error of (5%).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.