BackgroundTigertriever (Rapid Medical, Yoqneam, Israel) is a new design of stent retriever.PurposeTo evaluate the feasibility, safety, and efficacy of the Tigertriever in patients with acute ischemic stroke who have undergone mechanical thrombectomy.Materials and methodsTwo different techniques—namely, standard unsheathing (SUT) and repetitive inflation-deflation (RID) techniques, were used. Modified Thrombolysis in Cerebral Infarction (mTICI) scores of 2b and 3 were considered as successful recanalization.ResultsA total of 61 thrombectomy procedures with Tigertriever were retrospectively evaluated. The mean age of patients was 60.7 years and their National Institutes of Health Stroke Scale score was 14.7. Overall, the percentage of patients with a mTICI score of 0, 2b, and 3 was 24.6, 26.2, and 49.2, respectively. Successful recanalization and first-pass success rates were 75.4% and 37.7%, respectively. There were no statistical differences between the results of the SUT and RID techniques. No vessel rupture, dissection, or device detachment was observed. The number of patients with a good clinical outcome (modified Rankin Scale score 0–2) was 17 (27.9%).ConclusionOur results showed that the Tigertriever device is safe and efficient for mechanical thrombectomy.
Purpose The aim of this retrospective study is to evaluate medium-term results of undersized balloon angioplasty and stenting for symptomatic high-grade (70–99%) stenosis of a major intracranial artery with Enterprise stent. Methods This study included 68 consecutive symptomatic (recurrent transient ischemic attack (TIA) or ischemic stroke under dual antiplatelet treatment) patients with high-grade (70–99%) stenosis of a major intracranial artery who were endovascularly treated with undersized balloon angioplasty and Enterprise stent deployment between July 2012 and December 2017. Primary outcomes were any stroke or death within 30 days after procedure. Secondary outcomes were technical success rates, stroke and restenosis during the follow-up period. Results A total of 68 lesions in 68 patients (mean age: 62 ± 7 years) were treated with a technical success rate of 99%. The degree of pre-procedural stenosis was 92 ± 6% and dropped to 12 ± 10% after stent deployment. No patient developed any stroke or death during the periprocedural period. Intracranial hemorrhage was observed in 1 (1.5%) patient. In 60 (88%) patients with available imaging follow-up in-stent restenosis was observed in 2 patients. Mean follow-up period was 22 ± 17 months (range 6–72) and none of the patients experienced recurrent TIA or stroke during the follow-up period. Conclusion In this retrospective single-center study undersized balloon angioplasty and deployment of a self-expandable stent with relatively low radial force was safe and effective for endovascular treatment of high-grade intracranial arterial stenosis with high technical success rate, low periprocedural complication rates and favorable medium-term follow-up results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.