The skeleton’s osteogenic response to mechanical loading can be affected by loading duration and rest insertion during a series of loading events. Prior animal loading studies have shown that the cortical bone response saturates quickly and short rest insertions between load cycles can enhance cortical bone formation. However, it remains unknown how loading duration and short rest insertion affect load-induced osteogenesis in the mouse tibial compressive loading model, and particularly in cancellous bone. To address this issue, we applied cyclic loading (-9 N peak load; 4 Hz) to the tibiae of three groups of 16 week-old female C57BL/6 mice for two weeks, with a different number of continuous load cycles applied daily to each group (36, 216 and 1200). A fourth group was loaded under 216 daily load cycles with a 10 s rest insertion after every fourth cycle. We found that as few as 36 load cycles per day were able to induce osteogenic responses in both cancellous and cortical bone. Furthermore, while cortical bone area and thickness continued to increase through 1200 cycles, the incremental increase in the osteogenic response decreased as load number increased, indicating a reduced benefit of the increasing number of load cycles. In the proximal metaphyseal cancellous bone, trabecular thickness increased with load up to 216 cycles. We also found that insertion of a 10 s rest between load cycles did not improve the osteogenic response of the cortical or cancellous tissues compared to continuous loading in this model given the age and sex of the mice and the loading parameters used here. These results suggest that relatively few load cycles (e.g. 36) are sufficient to induce osteogenic responses in both cortical and cancellous bone in the mouse tibial loading model. Mechanistic studies using the mouse tibial loading model to examine bone formation and skeletal mechanobiology could be accomplished with relatively few load cycles.
Long noncoding RNA KCNQ1OT1 participates in the regulation of imprinted genes within the kcnq1 domain. But its roles in carcinogenesis and metastasis remain largely elusive. Herein, we evaluated its potential in non‐small‐cell lung cancer (NSCLC) progression. We demonstrated that the KCNQ1OT1 level was upregulated in NSCLC tissues and cell lines. High KCNQ1OT1 level correlated with poor overall and progression‐free survival in NSCLC patients. KCNQ1OT1 facilitated proliferation, migration, and invasion in H460 cells. Furthermore, knockdown of KCNQ1OT1 reduced the expression of HSP90AA1. KCNQ1OT1 presented a positive correlation with HSP90AA1 which predicted the tumor progression in NSCLC from The Cancer Genome Atlas database. Intriguingly, KCNQ1OT1 modulated HSP90AA1 expression by sponging miR‐27b‐3p. MiR‐27b‐3p counteracted the effect of KCNQ1OT1 on HSP90AA1 expression, H460 cell migration, and invasion. These data revealed a role for KCNQ1OT1 as an oncogene through miR‐27b‐3p/HSP90AA1 axis during NSCLC progression.
A variety of reasons, specifically contact issues, irregular loads, cracks in insulation, defective relays, terminal junctions and other similar issues, increase the internal temperature of electrical instruments. This results in unexpected disturbances and potential damage to power equipment. Therefore, the initial prevention measures of thermal anomalies in electrical tools are essential to prevent power-equipment failure. In this article, we address this initial prevention mechanism for power substations using a computer-vision approach by taking advantage of infrared thermal images. The thermal images are taken through infrared cameras without disturbing the working operations of power substations. Thus, this article augments the non-destructive approach to defect analysis in electrical power equipment using computer vision and machine learning. We use a total of 150 thermal pictures of different electrical equipment in 10 different substations in operating conditions, using 300 different hotspots. Our approach uses multi-layered perceptron (MLP) to classify the thermal conditions of components of power substations into "defect" and "non-defect" classes. A total of eleven features, which are first-order and second-order statistical features, are calculated from the thermal sample images. The performance of MLP shows initial accuracy of 79.78%. We further augment the MLP with graph cut to increase accuracy to 84%. We argue that with the successful development and deployment of this new system, the Technology Department of Chongqing can arrange the recommended actions and thus save cost in repair and outages. This can play an important role in the quick and reliable inspection to potentially prevent power substation equipment from failure, which will save the whole system from breakdown. The increased 84% accuracy with the integration of the graph cut shows the efficacy of the proposed defect analysis approach.
To provide mechanistic insight into the etiology of osteoporotic wedge fractures, we investigated the spatial distribution of tissue at the highest risk of initial failure within the human vertebral body for both forward flexion and uniform compression loading conditions. Micro-CT-based linear elastic finite element analysis was used to virtually load 22 human T9 vertebral bodies in either 5° of forward flexion or uniform compression; we also ran analyses replacing the simulated compliant disc (E = 8 MPa) with stiff polymethylmethacrylate (PMMA, E = 2,500 MPa. As expected, we found that, compared to uniform compression, forward flexion increased the overall endplate axial load on the anterior half of the vertebra and shifted the spatial distribution of high-risk tissue within the vertebra towards the anterior aspect of the vertebral body. However, despite that shift, the high-risk tissue remained primarily within the central regions of the trabecular bone and endplates, and forward flexion only slightly altered the ratio of cortical-to-trabecular load sharing at the mid-vertebral level (mean ± SD for n = 22: 41.3% ± 7.4% compression; 44.1% ± 8.2% forward flexion). When the compliant disc was replaced with PMMA, the anterior shift of high-risk tissue was much more severe. We conclude that, for a compliant disc, a moderate degree of forward flexion does not appreciably alter the spatial distribution of stress within the vertebral body.
Dynamization, increasing the interfragmentary movement (IFM) by reducing the fixation stiffness from a rigid to a more flexible condition, is widely used clinically to promote fracture healing. However, it remains unknown how dynamization degree (relative change in fixation stiffness/IFM from a rigid to a flexible fixation) affects bone healing at various stages. To address this issue, we used a fuzzy logic-based mechano-regulated tissue differentiation algorithm on published experimental data from a sheep osteotomy healing model. We applied a varied degree of dynamization, from 0 (fully rigid fixation) to 0.9 (90% reduction in stiffness relative to the rigid fixation) after 1, 2, 3, and 4 weeks of osteotomy (R1wF, R2wF, R3wF, and R4wF) and computationally evaluated bone regeneration and biomechanical integrity over the healing process of 8 weeks. Compared with the constant rigid fixation, early dynamization (R1wF and R2wF) led to delays in bone bridging and biomechanical recovery of the osteotomized bone. However, the effect of early dynamization on healing was dependent of the degree of dynamization. Specifically, a higher dynamization degree (e.g., 0.9 for R1wF) led to a prolonged delay in bone bridging and largely unrecovered bending stiffness (48% relative to the intact bone), whereas a moderate degree of dynamization (e.g., 0.5 or 0.7) significantly enhanced bone formation and biomechanical properties of the osteotomized bone. These results suggest that dynamization degree and timing interactively affect the healing process. A combination of early dynamization with a moderate degree could enhance the ultimate biomechanical recovery of the fractured bone.
The mechanism of vertebral wedge fractures remains unclear and may relate to typical variations in the mechanical behavior of the intervertebral disc. To gain insight, we tested 16 individual whole discs (between levels T8 and L5) from nine cadavers (mean ± SD: 66 ± 16 years), loaded in compression at different rates (0.05–20.0% strain/sec), to measure a homogenized “effective” linear elastic modulus of the entire disc. The measured effective modulus, and average disc height, were then input and varied parametrically in micro-CT-based finite element models (60-µm element size, up to 80 million elements each) of six T9 human vertebrae that were virtually loaded to 3° of moderate forward-flexion via a homogenized disc. Across all specimens and loading rates, the measured effective modulus of the disc ranged from 5.8 to 42.7 MPa and was significantly higher for higher rates of loading (p < 0.002); average disc height ranged from 2.9 to 9.3 mm. The parametric finite element analysis indicated that, as disc modulus increased and disc height decreased across these ranges, the vertebral bone stresses increased but their spatial distribution was largely unchanged: most of the highest stresses occurred in the central trabecular bone and endplates, and not anteriorly. Taken together with the literature, our findings suggest that the effective modulus of the human intervertebral disc should rarely exceed 100 MPa and that typical variations in disc effective modulus (and less so, height) minimally influence the spatial distribution but can appreciably influence the magnitude of stress within the vertebral body.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.