SUMMARYA smeared crack approach has been proposed to model the static and dynamic behavior of mass concrete in three-dimensional space. The proposed model simulates the tensile fracture on the mass concrete and contains pre-softening behavior, softening initiation, fracture energy conservation and strain rate e ects under dynamic loads. The validity of the proposed model has been checked using the available experimental results under static and dynamic loads. The direct and indirect displacement control algorithms have been employed under incremental increasing static loads. It was found that the proposed model gives excellent results and crack proÿles when compared with the available data under static loads. The Koyna Dam in India has been used to verify the dynamic behavior of the proposed model. It was found that the resulting crack proÿles were in good agreement with the available experimental results. Finally, the Morrow Point Dam was analyzed, including the dam-reservoir interaction e ects, to consider its non-linear seismic behavior. It was found that the resulting crack proÿles were in good agreement with the contour of maximum principal stresses and no numerical instability occurred during the analysis.
The Dez dam was commissioned in 1963 and since sediments accumulated in the reservoir up to an elevation of approximately 15m below the intake of the power tunnel. One of the possible measures to improve operation of the reservoir is by heightening of the existing dam. This paper describes the conducted procedure for static and thermal calibration of this 203m dam in Iran based on micro geodesies measurements. Also the nonlinear response of existing dam is investigated under maximum credible earthquake ground motions considering joint behavior and mass concrete cracking and safety of dam is evaluated for possible heightening. For thermal calibration of provided numerical model, transient thermal analysis was conducted and results were compared with thermometers records installed in central block. In addition, for static calibration; thermal distribution within dam body, dam self weight, hydrostatic pressure and silt load applied on the 3D finite element model of dam-reservoir-foundation were considered. Results show that the distribution of stresses will be critical within dam for heightening case under seismic loads in MCL.
The effect of solar radiation on thermal distribution in thin high arch dams is investigated. The differential equation governing thermal behavior of mass concrete in three-dimensional space is solved applying appropriate boundary conditions. Solar radiation is implemented considering the dam face direction relative to the sun, the slop relative to horizon, the region cloud cover, and the surrounding topography. It has been observed that solar radiation changes the surface temperature drastically and leads to nonuniform temperature distribution. Solar radiation effects should be considered in thermal transient analysis of thin arch dams.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.