A new practical and time-saving ultra-high performance liquid chromatography (UHPLC) method has been developed for determining the organic impurities in the anthraquinone color additives D&C Violet No. 2 and D&C Green No. 6. The impurities determined are p-toluidine, 1-hydroxyanthraquinone, 1,4-dihydroxyanthraquinone, and two subsidiary colors. The newly developed UHPLC method uses a 1.7-μ particle size C-18 column, 0.1 M ammonium acetate and acetonitrile as eluents, and photodiode array detection. For the quantification of the impurities, six-point calibration curves were used with correlation coefficients that ranged from 0.9974 to 0.9998. Recoveries of impurities ranged from 99 to 104%. Relative standard deviations ranged from 0.81 to 4.29%. The limits of detection for the impurities ranged from 0.0067% to 0.216%. Samples from sixteen batches of each color additive were analyzed, and the results favorably compared with the results obtained by gravity-elution column chromatography, thin-layer chromatography, and isooctane extraction. Unlike with those other methods, use of the UHPLC method permits all of the impurities to be determined in a single analysis, while also reducing the amount of organic waste and saving time and labor. The method is expected to be implemented by the U.S. Food and Drug Administration for analysis of color additive samples submitted for batch certification.
Specifications in the U.S. Code of Federal Regulations for the color additive D&C Red No. 17 (R17, Colour Index No. 26100) limit the levels of the dye’s intermediates, aniline (AN), 2-naphthol (β-naphthol, BN), and 4-aminoazobenzene (4AAB), to 0.2, 0.2, and 0.1%, respectively. The present work reports the development and application of an ultra-HPLC method for the quantitative determination of these impurities in R17. A 1.7 μm particle size C-18 column was used with 0.2 M ammonium acetate and acetonitrile as the eluents. AN, BN, and 4AAB were quantified by using six-point calibration curves with data points (w/w) ranging from 0.01 to 0.25% for AN, 0.01 to 0.24% for BN, and 0.01 to 0.19% for 4AAB. The correlation coefficients ranged from 0.9992 to 0.9999. Limits of detection for the analytes ranged from 0.002 to 0.01%. Recoveries of the analytes ranged from 99.5 to 102%. Relative standard deviations ranged from 0.482 to 1.262%. The new method was applied to analyze portions from 22 batches of R17 submitted to the U.S. Food and Drug Administration for certification. It was found to be simpler to implement, faster, and more sensitive than the older gravity-elution column chromatography method, which it has replaced.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.