ABSTRACT.Purpose: To assess the effects of adding dorzolamide to timolol monotherapy on ocular haemodynamics and retinal oxygen saturation in patients with primary open-angle glaucoma (POAG).Methods: Twenty-four patients (12 healthy, 12 with POAG) were treated with dorzolamide ⁄ timolol combination (DT) versus timolol maleate 0.5% twice daily in a randomized, crossover, double-blind study conducted over a period of 18 months. Patients received each treatment for 8 months then crossed over to the other treatment after a 1-month washout and second baseline. Goldmann applanation tonometry, Heidelberg retinal flowmetry (HRF), colour Doppler imaging (CDI) and retinal photographic oximetry were performed at each visit.Results: DT significantly reduced intraocular pressure (IOP) in both glaucomatous [right eye (OD) )13.15%, left eye (OS) )14.43%; p < 0.036] and non-glaucomatous (OD )12.4%, OS )13.88%; p < 0.039) patients compared to timolol after 8 months of treatment. DT significantly reduced the number of zero blood flow pixels in the superior ()39.72%; p < 0.014) and inferior ()51.44%; p < 0.008) retina in the nonglaucomatous group and inferior retina in the glaucomatous group ()55.38%, p < 0.006). The continuation of timolol monotherapy from baseline did not change (p < 0.05) any measured parameter and neither treatment had a significant effect (p < 0.05) on retinal oximetry or CDI parameters.
Conclusion:The addition of dorzolamide to timolol monotherapy decreases IOP and increases retinal blood flow in the superficial retinal vasculature in both glaucomatous and healthy patients following 8 months of treatment. The combination of increased retinal blood flow with consistent oxygen saturation may potentially increase oxygen delivery to the retina.
In this group of patients with OAG, there was a strong correlation between GAT and DCT measurements of IOP. IOP measured with DCT was consistently higher than IOP measured with GAT. Neither GAT nor DCT measurements were correlated with CCT. This data suggests that factors other than CCT may be involved in the tendency of DCT to produce higher measures of IOP than GAT.
This paper presents a novel and alternative methodology of logic/functional verification of a system-on-a-chip integratedcircuit. This methodology was used by our company for a successful and timely tape-out of our SoC. We will show a complete verification methodology that resulted in a fullyfunctional first silicon and quick time to market.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.