Goldmann Applanation Tonometry and Dynamic Contour Tonometry are not Correlated With Central Corneal Thickness in Primary Open Angle Glaucoma

Abstract: In this group of patients with OAG, there was a strong correlation between GAT and DCT measurements of IOP. IOP measured with DCT was consistently higher than IOP measured with GAT. Neither GAT nor DCT measurements were correlated with CCT. This data suggests that factors other than CCT may be involved in the tendency of DCT to produce higher measures of IOP than GAT.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
4
0
1

Year Published

2013
2013
2018
2018

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 17 publications
1
4
0
1
Order By: Relevance
“…Recent studies have showed an established difference in IOP levels measured by DCT and GAT that varies between 0.8 and 4.9 mm Hg and exhibits, in most cases, statistically significantly higher IOP readings using the Pascal tonometer. [8][9][10][13][14][15][16][17][18][19][20][21][22][23]26,27 In the present study, DCT readings were a mean -SD of 4.3 -2.1 mm Hg higher than GAT readings (P < 0.0001), a difference that is comparable to those reported by other authors.…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…Recent studies have showed an established difference in IOP levels measured by DCT and GAT that varies between 0.8 and 4.9 mm Hg and exhibits, in most cases, statistically significantly higher IOP readings using the Pascal tonometer. [8][9][10][13][14][15][16][17][18][19][20][21][22][23]26,27 In the present study, DCT readings were a mean -SD of 4.3 -2.1 mm Hg higher than GAT readings (P < 0.0001), a difference that is comparable to those reported by other authors.…”
Section: Discussionsupporting
confidence: 92%
“…6 Many authors tend to confirm that DCT measurements are independent of CCT. [6][7][8]10,12,14,21 Recent studies claim a significantly lower correlation of CCT with DCT than with GAT. 9,11,13,16,19,20,22 With regard to the difference between GAT and DCT in IOP measurements, increased CCT was found to correlate with decreased DIOP.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…(61, 113) The average value of IOP over a cardiac cycle can be measured via Goldmann applanation tonometry, while IOP oscillations over a cardiac cycle can be measured via PASCAL Dynamic Contour Tonometer. (97) …”
Section: Techniques For Non-invasive Ocular Measurementsmentioning
confidence: 99%
“…기존의 여러 연구에서 파스칼 안압계로 측정한 안압은 CCT와 통계학적으로 유의한 연관 관계가 없다는 결과가 있었으나, [13][14][15] Grieshaber p<0.001) (Fig. 1).…”
unclassified