Most of the biomaterials used nowadays for the reconstruction of the spinal cord (SC) tissue after an injury, tested in animals, have obtained modest results. This work presents a study about the compatibility of two novel, non-biodegradable, semi-conductive materials, obtained by plasma polymerization: iodine-doped pyrrole (PPy/I) and pyrrole-polyethylene glycol (PPy/PEG). Both polymers, separately, were implanted in the SC tissue of rats after a transection. Prior to implantation, the elemental composition and the physico-chemical properties of polymers were studied by electron scanning microscopy, IR Spectroscopy and thermogravimetric analysis. We used adult female Long Evans rats, subjected to SC transection. Animals were randomized to be allocated in one of the treatment groups and were killed four weeks after the lesion for histology study. Results showed that both implants were integrated to the SC tissue, as inflammatory and gliotic responses, similar to those observed in the control group, and rejection of the implant, were not evident. Moreover, the immediate effect of PPy/I or PPy/PEG in the injured SC prevented secondary tissue destruction, as compared to non-implanted control animals. In conclusion, implants of semi-conductive polymers were well-tolerated and integrated favorably to SC tissue after transection.
Currently, there is no universally accepted treatment for traumatic spinal cord injury (TSCI), a pathology that can cause paraplegia or quadriplegia. Due to the complexity of TSCI, more than one therapeutic strategy may be necessary to regain lost functions. Therefore, the present study proposes the use of implants of mesoparticles (MPs) of polypyrrole/iodine (PPy/I) synthesized by plasma for neuroprotection promotion and functional recovery in combination with treadmill training (TT) for neuroplasticity promotion and maintenance of muscle tone. PPy/I films were synthesized by plasma and pulverized to obtain MPs. Rats with a TSCI produced by the NYU impactor were divided into four groups: Vehicle (saline solution); MPs (PPy/I implant); Vehicle-TT (saline solution + TT); and MPs-TT (PPy/I implant + TT). The vehicle or MPs (30 μL) were injected into the lesion site 48 h after a TSCI. Four days later, TT was carried out 5 days a week for 2 months. Functional recovery was evaluated weekly using the BBB motor scale for 9 weeks and tissue protection using histological and morphometric analysis thereafter. Although the MPs of PPy/I increased nerve tissue preservation (P = 0.03) and promoted functional recovery (P = 0.015), combination with TT did not produce better neuroprotection, but significantly improved functional results (P = 0.000) when comparing with the vehicle group. So, use these therapeutic strategies by separately could stimulate specific mechanisms of neuroprotection and neuroregeneration, but when using together they could mainly potentiate different mechanisms of neuronal plasticity in the preserved spinal cord tissue after a TSCI and produce a significant functional recovery. The implant of mesoparticles of polypyrrole/iodine into the injured spinal cord displayed good integration into the nervous tissue without a response of rejection, as well as an increased in the amount of preserved tissue and a better functional recovery than the group without transplant after a traumatic spinal cord injury by contusion in rats. The relevance of the present results is that polypyrrole/iodine implants were synthesized by plasma instead by conventional chemical or electrochemical methods. Synthesis by plasma modifies physicochemical properties of polypyrrole/iodine implants, which can be responsible of the histological response and functional results. Furthermore, no additional molecules or trophic factors or cells were added to the implant for obtain such results. Even more, when the implant was used together with physical rehabilitation, better functional recovery was obtained than that observed when these strategies were used by separately.
We studied the use of three biocompatible materials obtained by plasma polymerization of pyrrole (PPy), pyrrole doped with iodine (PPy/I) and a copolymer formed with pyrrole and polyethylene glycol (PPy/PEG), implanted, separately, after a complete spinal cord transection in rats. Motor function assessed with the BBB scale and somatosensory evoked potentials (SEPs) in the implanted rats were studied. Results showed that the highest motor recovery was obtained in rats with PPy/I implants. They also showed a significant reduction in the latency of SEPs. Histological analyses showed no signs of implant rejection; on the contrary, implants based on PPy improved the SEPs conduction and motor function after lesion.
ABSTRACT:Composites of natural fibers and thermoplastics can be combined to form new enhanced materials.One of the problems involved in this type of composites is the formation of chemical bonds between the fibers and the polymers at the interface. This work presents a study where low energy glow discharge plasmas are used to functionalize cellulose fibers implanting polystyrene between the fibers and the matrix that improve the adhesion of both components. The interface of polystyrene was synthesized by continuous and periodic glow discharges on the surface of the cellulose fibers. The results show that the adhesion in the fiber-matrix interface increases with time in the first 4 min of treatment. However, at longer plasma exposures, the fiber may be degraded reducing the adhesion with the matrix.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.