The results demonstrated that DTFC is more effective in reducing IOP than latanoprost and travoprost. Latanoprost and travoprost had similar ocular hypotensive effects in patients with PXG. All three drugs were well tolerated; there were fewer ocular side effects attributable in the latanoprost group. (Eur J Ophthalmol 2006; 15: 73-80).
This study demonstrates that vitamin D deficiency is associated with tear hyperosmolarity and tear film dysfunction. Patients with vitamin D deficiency may be prone to dry eye.
The results of this study showed that psoriasis may influence tear osmolarity and tear film function. Patients with psoriasis showed tear hyperosmolarity and tear film dysfunction.
Photorefractive devices have been evaluated for their effectiveness in detecting anisometropia, hyperopia, myopia, and astigmatism. We investigated the reliability of Plusoptix S08, the newest photoscreener, and Topcon autorefractometer by comparing them with cycloplegic retinoscopy. Plusoptix S08, cycloplegic retinoscopy, and cycloplegic autorefractometer measurements for 235 eyes of 118 children (59 female, 59 male) with a mean age of 4.9 ± 2.6 and median age of 5 years (range 1-12) were conducted. The Plusoptix S08 produced the following mean (± SD) results--spherical 0.27 ± 1.64, cylindrical power -0.81 ± 0.71, axis 89.73 ± 61.18, and spherical equivalent -0.05 ± 1.61. The cycloplegic retinoscopy produced the following mean (± SD) results--spherical 0.12 ± 1.35, cylindrical power -0.89 ± 0.71, axis 92.18 ± 68.39, and spherical equivalent -0.15 ± 1.31. The cycloplegic autorefractometer produced the following mean (± SD) results--spherical 0.16 ± 1.44, cylindrical power -0.88 ± 0.72, axis 90.86 ± 68.21, and spherical equivalent -0.12 ± 1.41. This study has shown that cycloplegic autorefractometer and retinoscopy results are similar and Plusoptix S08 is a very safe, easy-to-use and reliable screening method of refraction, especially for ophthalmologists unskilled in retinoscopy. Plusoptix S08 is a useful tool for estimating refraction in patients for whom conventional autorefraction is not an option.
Objectives:To compare epithelial healing time following laser epithelial keratomileusis (LASEK) and photorefractive keratectomy (PRK) with anterior segment optic coherence tomography (AS-OCT).Methods:This prospective interventional case series study comprised 56 eyes of 28 patients that underwent laser refractive surgery in the Department of Ophthalmology, Medipol University Medical Faculty, Istanbul, Turkey, between March 2014 and May 2014. Each patient was randomized to have one eye operated on with PRK, and the other with LASEK. Patients were examined daily for 5 days, and epithelial healing time was assessed by using AS-OCT without removing therapeutic contact lens (TCL). Average discomfort scores were calculated from ratings obtained from questions regarding pain, photophobia, and lacrimation according to a scale of 0 (none) to 5.Results:The mean re-epithelialization time assessed with AS-OCT was 3.07±0.64 days in the PRK group, 3.55±0.54 days in the LASEK group, and the difference was statistically significant (p=0.03). Mean subjective discomfort score was 4.42±0.50 in the PRK eyes, and 2.85±0.44 in the LASEK eyes on the first exam day (p=0.001). The score obtained on the second (p=0.024), and third day (p=0.03) were also statistically significant. The fourth (p=0.069), and fifth days scores (p=0.1) showed no statistically significant difference between groups.Conclusion:The PRK showed a statistically significant shorter epithelial healing time, but had a statistically significant higher discomfort score until the postoperative fourth day compared with LASEK.
To evaluate the effectiveness of an intravitreal bevacizumab injection on retinal neovascularization and diabetic macular edema (DME) refractory to laser photocoagulation therapy. Thirty-four eyes of 22 patients with proliferative diabetic retinopathy and DME refractory to laser photocoagulation therapy received an intravitreal injection of 1.25 mg/0.05 ml of bevazicumab. Changes in mean best-corrected visual acuity (BCVA), central macular thickness (CMT), regression of neovascularization over time, and correlation between BCVA and CMT were evaluated. Follow-up visits were at weeks 1, 2 and 4 and months 3 and 6. Mean BCVA was significantly better than baseline only at week 2 (P = 0.036). Mean CMT decreased significantly from baseline at weeks 1, 2, and 4 (P = 0.001). At months 3 and 6, mean CMT increased, albeit insignificantly (P = 0.804 and P = 1.0). The decrease in fluorescein leakage was moderate in all eyes at the end of week 1. At week 2, there was total resolution of fluorescein leakage in 24 (70.5%) eyes and moderate resolution in 10 (29.5%) eyes. At the end of month 3, the fluorescein leakage was fully resolved in 5 (14.7%) eyes, moderately resolved in 24 (70.5%) eyes, and was similar to baseline in 5 (14.7%) eyes. At month 6, the fluorescein leakage was fully resolved in 3 (8.8%) eyes, moderately resolved in 20 (58.8%) eyes, and was similar to baseline in 11 (32.4%) eyes. A moderate but insignificant negative correlation was found between visual acuity and CMT (P > 0.05). Persistence or recurrence of neovascular tissue after panretinal photocoagulation may be attributed to the production of vascular endothelial growth factor by the residual ischemic retina, which also results in persistent or recurrent DME despite macular grid photocoagulation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.