AimsTo investigate an influence of mucopolysaccharidosis (MPS)- and Morbus Fabry-associated corneal opacities on intraocular pressure (IOP) measurements and to evaluate the concordance of the different tonometry methods.Methods25 MPS patients with or without corneal clouding, 25 Fabry patients with cornea verticillata ≥ grade 2 and 25 healthy age matched controls were prospectively included into this study. Outcome measures: Goldmann applanation tonometry (GAT); palpatory assessment of IOP; Goldmann-correlated intraocular pressure (IOPg), corneal-compensated intraocular pressure (IOPcc), corneal resistance factor (CRF) and corneal hysteresis (CH) assessed by Ocular Response Analyzer (ORA); central corneal thickness (CCT) and density assessed with Pentacam. Statistical analysis was performed using linear mixed effect models and Spearman correlation coefficients. The concordance between tonometry methods was assessed using Bland-Altman analysis.ResultsThere was no relevant difference between study groups regarding median GAT, IOPg, IOPcc and CCT measurements. The limits of agreement between GAT and IOPcc/IOPg/palpatory IOP in MPS were: [-11.7 to 12.1mmHg], [-8.6 to 15.5 mmHg] and [- 5.4 to 10.1 mmHg] respectively. Limits of agreement were less wide in healthy subjects and Fabry patients. Palpatory IOP was higher in MPS than in healthy controls and Fabry patients. Corneal opacity correlated more strongly with GAT, IOPg, CH, CRF, CCT and corneal density in MPS (r = 0.4, 0.5, 0.5, 0.7, 0.6, 0.6 respectively) than in Fabry patients (r = 0.3, 0.2, -0.03, 0.1, 0.3, -0.2 respectively). In contrast, IOPcc revealed less correlation with corneal opacity than GAT in MPS (r = 0.2 vs. 0.4).ConclusionsORA and GAT render less comparable IOP-values in patients suffering from MPS-associated corneal opacity in comparison to Fabry and healthy controls. The IOP seems to be overestimated in opaque MPS-affected corneas. GAT, IOPg and biomechanical parameters of the cornea correlate more strongly with the corneal clouding than IOPcc in MPS patients.Trial RegistrationClinicalTrials.gov NCT01695161
Aims To report corneal topometric and aberrometric values in mucopolysaccharidosis (MPS) and to investigate their correlation with biomechanical corneal parameters. Methods One randomly chosen eye of 20 MPS patients with no to moderate corneal clouding and one eye of 23 healthy controls with comparable age were prospectively included into this study. Corneal surface regularity was assessed by index of surface variance (ISV), -vertical asymmetry (IVA), -height asymmetry (IHA), -height decentration (IHD); keratoconus index (KI), central keratoconus index (CKI) and Zernike indices of anterior and posterior corneal surface using Scheimpflug imaging (Pentacam). Corneal resistance factor (CRF) and corneal hysteresis (CH) were assessed by Ocular Response Analyzer. Statistical analyses were performed using Mann-Whitney-Test and Spearman Correlation Coefficients. Results IVA, ISV, IHD, IHA, but not KI and CKI were significantly higher in MPS patients compared to age matched healthy controls. Spherical aberration and asphericity coefficients either at the anterior or at the posterior corneal surface differed significantly between both groups. The grade of the MPS-associated corneal opacity correlated significantly with ISV (rho = 0.52), IVA (rho = 0.54), IHA (rho = 0.57) and IHD (rho = 0.48). Density of the MPS-affected corneas correlated significantly with ISV (rho = 0.52), IVA (rho = 0.72), IHA (rho = 0.57), IHD (rho = 0.69), 3rd order horizontal trefoil aberration at the posterior (rho = 0.62) and anterior surface (rho = 0.48) as well as with CH (rho = 0.55) and CRF (rho = 0.57). Spherical aberration at the back surface correlated with CRF and CH in MPS and in healthy controls. Conclusions This is the first study analyzing shape of the corneal surface in MPS patients. Topometric indices of corneal asymmetry are significantly increased and correlate with MPS-related corneal opacity and density. Spherical aberration and asphericity coefficient at the front and at the back corneal surface differ significantly between MPS and healthy controls.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.