Along with increase in the frequency and exposure dose from the diagnostic medical radiation procedures, the public's interest in radiation exposure has also been growing. In this study, in order to estimate the Cumulative Exposure Frequency and the cumulative effective dose of diagnostic medical radiation in the Korean population, we included 680 diagnostic medical radiation procedure codes of the Health Insurance Review & Assessment Service's health insurance medical expenses data and adopted the effective dose data from the 2008 report of the United Nations Scientific Committee on the Effects of Atomic Radiation. We combined the data of one million individuals in the national sample cohort database (2002-10) of the National Health Insurance Service. The results revealed that 93.2% (917 972) of the subjects were exposed to diagnostic medical radiation at least once in the past nine years, and the Cumulative Exposure Frequency was 17 286.4 per 1000 individuals with a cumulative effective dose of 5.7 (±17.8) mSv per person. Additionally, 93.1% (854 480) of the subjects had a cumulative effective dose less than 20 mSv, and 0.7% (6139) had a dose that exceeded 100 mSv (extreme), showing that the dosage level was mostly low. However, the number of individuals whose exposure exceeded 100 mSv/y increased 28-fold, from 18 in 2002 to 500 in 2010. In addition, the size of increase also grew each year, suggesting that cancer occurrence due to diagnostic medical radiation may have also increased. In order determine the causal relationship between cancer occurrence and diagnostic medical radiation and setup a guideline for exposure, it is necessary to monitor individual cumulative exposure doses nation-wide and follow up on heavily exposed individuals for an extended period of time.
This study was to improve to utilization of non dosimetry measurements for X-ray radiography. Experiments was passed off varying the X-ray tube voltage and the thickness of the aluminum filter by actual dose. Calculated results was set to the first beam quality factors, calculated first correction coefficient by the Microsoft Excel program was set as the second beam quality factors. To make the non dosimetry measurements simply, the Excel program apply to the new beam quality factors, the error was compared to the previous studies, and the results verify the calculated value of smaller errors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.