ObjectivesVisual acuity is a common measurement in general practice, and the advent of new technology such as tablet computers offers a change in the way in which these tests are delivered. The aim of this study was to assess whether measurements of distance visual acuity using LogMAR letter charts displayed on an iPad tablet computer were in agreement with standard clinical tests of visual acuity in adults with normal vision.DesignBlinded, diagnostic test study.SettingSingle centre (University) in Auckland, New Zealand.ParticipantsUniversity staff and students (n=85). Participants were required to have visual acuity better than 6/60 and wear habitual refractive correction during testing. Participants were excluded if there was any history of ocular pathology.Primary and secondary outcome measuresVisual acuity measured under a number of conditions.ResultsThe iPad tablet with its glossy screen was highly susceptible to glare resulting in acuity measurements that were significantly poorer (approximately 2 LogMAR lines) than those made using an ETDRS chart and a standard computerised testing system (n=56). However, fitting the iPad with an antiglare screen and positioning the device away from sources creating reflected (veiling) glare resulted in acuity measurements that were equivalent those made using gold standard charts (n=29).ConclusionsTablet computers are an attractive option for visual acuity measurement due to portability, the ability to randomise letters, automated scoring of acuity and the ability to select from a range of charts. However, these devices are only suitable for use in situations where sources of glare can be eliminated.
Purpose:The aim was to determine the extent of daily disposable contact lens prescribing worldwide and to characterise the associated demographics and fitting patterns. Methods: Up to 1,000 survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for five consecutive years (2007 to 2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Survey data collected since 1996 were also analysed for seven nations to assess daily disposable lens fitting trends since that time. Results: Data were collected in relation to 97,289 soft lens fits, of which 23,445 (24.1 per cent) were with daily disposable lenses and 73,170 (75.9 per cent) were with reusable lenses. Daily disposable lens prescribing ranged from 0.6 per cent of all soft lenses in Nepal to 66.2 per cent in Qatar. Compared with reusable lens fittings, daily disposable lens fittings can be characterised as follows: older age (30.0 Ϯ 12.5 versus 29.3 Ϯ 12.3 years for reusable lenses); males are over-represented; a greater proportion of new fits versus refits; 85.9 per cent hydrogel; lower proportion of toric and presbyopia designs and a higher proportion of part-time wear. There has been a continuous increase in daily disposable lens prescribing between 1996 and 2011. The proportion of daily disposable lens fits (as a function of all soft lens fits) is positively related to the gross domestic product at purchasing power parity per capita (r 2 = 0.55, F = 46.8, p < 0.0001). Conclusions:The greater convenience and other benefits of daily disposable lenses have resulted in this modality capturing significant market share. The contact lens field appears to be heading toward a true single-use-only, disposable lens market.
ObjectiveTo evaluate the effect of weightlifting (leg press) on intraocular pressure (IOP).DesignProspective cohort study.SubjectsA total of 24 participants met the inclusion criteria and completed the study procedures. Participants had an average age of 22.7±2.7 years and included nine women. The mean baseline IOP was 13.9 mm Hg (SD=2.4) with an average body mass index of 24.5 (SD= 3.1).MethodsThe maximum load for a single lift was found for each participant. Participants then performed three leg press regimens: one repetition using 95% of maximal load (1RM), six repetitions using 75% of maximal load (6RM) and isometric push against a weight much heavier than maximal load (ISO).Main outcome measureIOP was measured pre-exercise, during and immediately following the exercise using an iCare TA01i rebound tonometer. Blood pressure and HR were being monitored continuously during the lift. Optical coherence tomography images were obtained pre and postexercise session.ResultsThe average maximum weight lifted by our participants was 331.9 Kg (SD=97.3). Transient increased IOP was observed across the 1RM, 6RM and ISO exercises with an average increase in 26.4 mm Hg (23.7 mm Hg to 28.7 mm Hg) to reach an average max IOP of 40.7 mm Hg (27.8 mm Hg to 54.2 mm Hg), with an absolute maximum of 70 mm Hg in one participant.ConclusionsThere is a transient and dramatic fluctuation in IOP with resistance training. This coupled with regular exposure to resistance training is potentially a significant risk factor for glaucoma. It should be noted that this study has been carried out in a healthy young population, and, thus, the external validity of these results in glaucoma participants requires further investigation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.