Background Laboratory tests and early clinical studies have shown that highly cross-linked polyethylene (PE) markedly improves wear resistance compared to conventional PE. We evaluated this type of PE in two randomized clinical studies using radiostereometric analysis (RSA). The 2-and 3-year follow-up of these studies have already been reported. We found a lower penetration rate for the highly cross-linked PE than for conventional PE. We now report the outcome after 5 years.Patients and methods 60 patients (61 hips) with a median age of 55 years were randomized to receive either highly cross-linked PE (Durasul) or conventional cemented all-polyethylene sockets of the same design. 55 patients (56 hips) were followed for 5 years. In the second study, 32 patients (64 hips) with a median age of 48 years and with bilateral primary or secondary osteoarthritis of the hip had hybrid total hip arthroplasty with liners made of highly cross-linked PE (Longevity) on one side and conventional PE on the other. 23 patients in this study have passed the 5-year follow-up.Results Bedding-in and creep for the Durasul all-PE was reached by 2 years, and by 1 year for the Longevity liners. In both control groups with conventional PE, this was reached by 6 months. The steady-state wear rate was close to zero in the two study groups and 0.06 mm/ year for the conventional PE in the two control groups.Interpretation We found that use of highly crosslinked PE instead of conventional PE reduced the wear by more than 95%, which supports continued use of this type of PE in young, active patients.
Background Polyethylene (PE) wear particles are believed to cause aseptic loosening and thereby impair function in hip arthroplasty. Highly crosslinked polyethylene (XLPE) has low short-and medium-term wear rates. However, the longterm wear characteristics are unknown and it is unclear whether reduced wear particle burden improves function and survival of cemented hip arthroplasty. Questions/purposes We asked whether XLPE wear rates remain low up to 10 years and whether this leads to improved implant fixation, periprosthetic bone quality, and clinical function compared to conventional PE. Methods We randomized 60 patients (61 hips) to receive either PE or XLPE cemented cups combined with a cemented stem. At 10 years postoperatively, 51 patients (52 hips) were evaluated for polyethylene wear and component migration estimation by radiostereometry, for radiolucent lines, bone densitometry, and Harris hip and pain scores. Revisions were recorded. Results XLPE cups had a lower mean three-dimensional wear rate between 2 and 10 years compared to conventional PE hips: 0.005 mm/year versus 0.056 mm/year. We found no differences in cup migration, bone mineral density, radiolucencies, functional scores, and revision rate. There was a trend toward improved stem fixation in the XLPE group. The overall stem failure rate was comparably high, without influencing wear rate in XLPE hips. Conclusions XLPE displayed a low wear rate up to 10 years when used in cemented THA, but we found no clear benefits in any other parameters. Further research is needed to determine whether cemented THA designs with XLPE are less prone to stem loosening.
The purpose of this study was to compare the efficacy of intravenous and topical tranexamic acid (TXA) versus control group for reduction in blood loss following primary total knee arthroplasty (TKA). A total of 90 patients were prospectively allocated to each of three groups (control, intravenous IV and intra-articular) and underwent unilateral total knee arthroplasty. In the IV group, patients received one dose of TXA of 15 mg/kg before deflation of the tourniquet, while in the intra-articular group patients received 2 g TXA via the drain retrogradely after closure of the wound. The mean drained blood loss in control, IV and intra-articular groups was 415 ± 24, 192 ± 21 and 121 ± 17 ml, respectively. About 43 % (control), 23 % (IV) and 17 % (intra-articular) of each group required transfusion, and the mean transfusion was 338, 168 and 79 ml, respectively. Preoperative hemoglobin values decreased at 24 h by 2.80 ± 0.14, 2.24 ± 0.17 and 2.26 ± 0.18 mg/dl, respectively. TXA reduced blood loss and transfusion requirement. Compared with one-dose intravenous administration, intra-articular administration of TXA seems to be more effective in terms of reducing drained blood loss and transfusion frequency. We recommend administration of topical TXA in primary TKA in healthy patients to decrease perioperative blood loss.
Background In cemented THA, aseptic loosening of the cup is more common than loosening of the stem, while periprosthetic osteolysis of the socket resulting in difficult reconstruction problems has emerged as the most significant problem with cementless cup fixation.Patients and methods 90 patients (96 hips) scheduled for THA were stratified in three groups according to the method of fixation of the acetabular component: acrylic bone cement with fluoride (Cemex-F), porous-coated press-fit cup with ceramic coating (Trilogy, uncemented) and acrylic cement with gentamicin (Palacos). All patients received the Spectron EF stem. Acetabular bone mineral density was measured with dual-energy X-ray absorptiometry (DXA) 1 week postoperatively, and after 12 and 24 months. The periprosthetic BMD was evaluated in 5 ROIs positioned around the acetabular component.Results In the uncemented sockets, the BMD had decreased proximally and medially to the cup after 2 years. The difference was significant in the proximal region as compared to the control group (Palacos). No difference was noted between the 2 groups with cemented components after 2 years. Stepwise linear regression analysis showed that loss of periprosthetic BMD in the proximal high-pressure region after 2 years increased with higher postoperative BMD and when the uncemented design had been used. Interpretation Contrary to previous studies of cemented stems, the use of fluoride cement did not influence the periprosthetic BMD 2 years after the examination. Increased loss of BMD with use of uncemented press-fit cups in the region in which osteolytic lesions are commonly found suggests that stress shielding may initiate the development of this complication. Longer
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.