We present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for example, blood permittivity depends on the blood glucose levels. The proposed sensing system uses two facing microstrip patch antennas operating at 60 GHz, which are placed across interrogated samples. The measured transmission coefficient depends on the permittivity change along the signal path, which can be correlated to the change in concentration of a substance. Along with theoretical estimations, we experimentally demonstrate the sensing performance of the system using controlled laboratory samples, such as water-based glucose-loaded liquid samples. We also present results of successful glucose spike detection in humans during an in-vivo Intravenous Glucose Tolerance Test (IVGTT). The system could eventually be developed into a non-invasive glucose monitor for continuous monitoring of glucose levels for people living with diabetes, as it can detect as small as 1.33 mmol/l (0.025 wt%) glucose concentrations in the controlled water-based samples satisfactorily, which is well below the typical human glucose levels of 4 mmol/l.
Endoscopes formed by arrays of metallic wires can transmit, magnify, and demagnify near-field distributions with subwavelength resolution. Our experiments demonstrate that despite their small apertures, the parallel multiwire endoscopes can be used to transmit near-field distributions with a resolution of five thousandths of a wavelength to a distance of a half-wavelength in the microwave frequency range, and tapered multiwire endoscopes with flat input and output interfaces provide threefold image magnification and demagnification.
We present a first prototype of a wideband microwave tomography system with potential application to medical imaging. The system relies on a compact and robust printed monopole antenna which can operate in the 1.0–3.0 GHz range when fully immersed in commonly used coupling liquids, such as glycerine–water solutions. By simulating the proposed imaging setup in CST Microwave Studio, we study the signal transmission levels and array sensitivity for different target and coupling liquid media. We then present the experimental prototype design and data acquisition process, and show good agreement between experimentally measured data and results from the CST simulations. We assess imaging performance by applying our previously proposed two-dimensional (2-D) DBIM TwIST-algorithm to both simulated and experimental datasets, and demonstrate that the system can reconstruct simple cylindrical targets at multiple frequencies.
We report on the optical and physical characterization of metallic nanowire (NW) metamaterials fabricated by electrodeposition of ≈30 nm diameter gold nanowires in nanoporous anodic aluminum oxide. We observe a uniaxial anisotropic dielectric response for the NW metamaterials that displays both epsilon-near-zero (ENZ) and epsilon-near-pole (ENP) resonances. We show that a fundamental difference in the behavior of NW metamaterials from metal-dielectric multilayer (ML) metamaterials is the differing directions of the ENZ and ENP dielectric responses relative to the optical axis of the effective dielectric tensor. In contrast to multilayer metamaterials, nanowire metamaterials exhibit an omnidirectional ENP and an angularly dependent ENZ. Also in contrast to ML metamaterials, the NW metamaterials exhibit ENP and ENZ resonances that are highly absorptive and can be effectively excited from free space. Our fabrication allows a large tunability of the epsilonnear-zero resonance in the visible and near-IR spectrum from 583 to 805 nm as the gold nanorod fill fraction changes from 26% to 10.5%. We support our fabrication process flow at each step with rigorous physical and optical characterization. Energy dispersive x-ray (EDX) and x-ray diffraction (XRD) analyses are used to ascertain the quality of electrochemically deposited Au nanowires prior to and after annealing. Our experimental results are in agreement with simulations of the periodic plasmonic crystal and also analytical calculations in the effective medium metamaterial limit. We also experimentally characterize the role of spatial dispersion at the ENZ resonance and show that the effect does not occur for the ENP resonance. The application of these materials to the fields of biosensing, quantum optics, and thermal devices shows considerable promise.
If citing, it is advised that you check and use the publisher's definitive version for pagination, volume/issue, and date of publication details. And where the final published version is provided on the Research Portal, if citing you are again advised to check the publisher's website for any subsequent corrections.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.