DIscLAiMER While this document is believed to contain correct information, neither the United States Deparlment of Energy (WE) nor any agency thereof, nor The Regents of the University of California (The Regents), nor the California Institute for Energy Efficiency (ClEE), nor any of CIEEs sponsors or supporters (including California electric and gas utilities), nor any of these organizations' employees, make any warranty, express or implied, or assume any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represent that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by its trade name, trademark, manufacturer, or otherwise, does not neceSSarily constitute or imply its endorsement, recommendation, or favoring by DOE or any agency thereof, or The Regents, or CIEE, or any of CTEE's sponsors or supporters. The views and opinions of authors expressed herein do not neceSSarily state or reflect those of W E or of any agency thereof, of The Regents, of CIEE, or any of CIEEs sponsors or supporters, and the names of any such organizations or their employees shall not be used for advertising or product endorsement purposes.
Laboratory facilities present a unique challenge for energy efficient design, partly due to their health and safety requirements. Recent experience has shown that there is significant energy efficiency potential in laboratory buildings. However, there is often a misperception in the laboratory community that energy efficiency will inherently compromise safety. In some cases, energy efficiency measures require special provisions to ensure that safety requirements are met. In other cases, efficiency measures actually improve safety. In this paper we present five major, yet under-utilized, energy efficiency strategies for ventilation-intensive laboratories and discuss their implications for health and safety. These include: (a) optimizing ventilation rates; (b) reducing laboratory chemical hood energy use; (c) low-pressure drop HVAC design; (d) right-sizing HVAC systems; and (e) reducing simultaneous heating and cooling. In all cases, the successful design and implementation of these strategies requires active and informed participation by health and safety personnel.
Increasing energy-efficient performance built into today’s servers has created significant opportunities for expanded Information and Communications Technology (ICT) capabilities. Unfortunately the power densities of these systems now challenge the data center cooling systems and have outpaced the ability of many data centers to support them. One of the persistent problems yet to be overcome in the data center space has been the separate worlds of the ICT and Facilities design and operations. This paper covers the implementation of a demonstration project where the integration of these two management systems can be used to gain significant energy savings while improving the operations staff’s visibility to the full data center; both ICT and facilities. The majority of servers have a host of platform information available to the ICT management network. This demonstration project takes the front panel temperature sensor data from the servers and provides that information over to the facilities management system to control the cooling system in the data center. The majority of data centers still use the cooling system return air temperature as the primary control variable to adjust supply air temperature, significantly limiting energy efficiency. Current best practices use a cold aisle temperature sensor to drive the cooling system. But even in this case the sensor is still only a proxy for what really matters; the inlet temperature to the servers. The paper presents a novel control scheme in which the control of the cooling system is split into two control loops to maximize efficiency. The first control loop is the cooling fluid which is driven by the temperature from the physically lower server to ensure the correct supply air temperature. The second control loop is the airflow in the cooling system. A variable speed drive is controlled by a differential temperature from the lower server to the server at the top of the rack. Controlling to this differential temperature will minimize the amount of air moved (and energy to do so) while ensuring no recirculation from the hot aisle. Controlling both of these facilities parameters by the server’s data will allow optimization of the energy used in the cooling system. Challenges with the integration of the ICT management data with the facilities control system are discussed. It is expected that this will be the most fruitful area in improving data center efficiency over the next several years.
Special thanks are extended to Jim Durborough and Manuel Lujano of the California Franchise Tax Board for their participation in this project. Additional thanks are extended to William Tschudi of Lawrence Berkeley National Laboratory for technical assistance and oversight of the project.
Standard ventilation design practice optimizes neither safety nor energy efficiency. Contemporary design process supports the labs' mission, incorporates codified requirements, and embraces the design team's goals by evolving beyond standard design practice. A variety of practical and innovative design strategies can be applied that ensure safety and advance energy efficiency. Design examples are provided that have studied and optimized lab ventilation effectiveness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.