Sweat‐related physiology research has been well established over the years. However, it has only been around ten years that sweat‐based sensing devices started to be explored. With the recent advancements in wearable activity and physiology monitoring devices, sweat was investigated for its contents similar to blood and corresponding wearable devices were studied intensively. This article provides a thorough review on sweating mechanisms, sweat sensing devices, and electronic technologies for sweat sensor implementations. Potential future directions and recommendations based on current research trends were provided in each section. This review aims to offer a unique perspective from both physiology and engineering point‐of‐view to draw a complete landscape of the sweat sensing research.
Dehydration is one of the most profound physiological challenges that significantly affects athletes and soldiers if not detected early. Recently, a few groups have focused on dehydration detection using sweat as the main biomarker. Although there are some proposed devices, the electrical and chemical characteristics of sweat have yet to be incorporated into the validations. In this work, we have developed a simple test setup to analyze artificial sweat that is comprised the main components of human sweat. We provide theoretical and experimental details on the electrical and chemical behavior of the artificial sweat for various concentration values within a temperature range of 5 °C to 50 °C. We have also developed an efficient sweat collecting and detection system based on 3D printing. Human studies were conducted and this particular protocol has shown that dehydration starts to take effect as early as 40 min into the physical activity if there is no fluid intake during the exercise. We believe that our device will lead to developing viable real-time sweat analysis systems.
This paper proposes and experimentally demonstrates a blind modulation format identification (MFI) method delivering high accuracy (> 99%) even in a low OSNR regime (< 10 dB). By using nonlinear power transformation and peak detection, the proposed MFI can recognize whether the signal modulation format is BPSK, QPSK, 8-PSK or 16-QAM. Experimental results demonstrate that the proposed MFI can achieve a successful identification rate as high as 99% when the incoming signal OSNR is 7 dB. Key parameters, such as FFT length and laser phase noise tolerance of the proposed method, have been characterized.
We describe the use of HNQ (2-hydroxy-1,4-naphthoquinone or Lawsone) as a potential sweat sensor material to detect the hydration levels of human beings. We have conducted optical measurements using both artificial and human sweat to validate our approach. We have determined that the dominant compound that affects HNQ absorbance in artificial sweat is sodium. The presence of lactate decreases the reactivity of HNQ while urea promotes more interactions of sodium and potassium ions with HNQ. The interactions between the hydroxyl group of HNQ and the artificial sweat components (salts, lactic acid, and urea) were investigated comprehensively. We have also proposed and developed a portable diode laser absorption sensor system that converts the absorbance at a particular wavelength range (at 455 ± 5 nm, where HNQ has an absorbance peak) into light intensity measurements via a photocell. The absorbance intensity values obtained from our portable sensor system agrees within 10.4% with measurements from a laboratory based ultraviolet-visible spectrometer. Findings of this research will provide significant information for researchers who are focusing on real-time, in-situ hydration level detection.
As dehydration continues to plague performance athletes and soldiers, the need for improved dehydration detection is clear. We propose the use of a conductometric sensor as the foundation of a sweat-sensing patch to address this need. The conductometric sensor evaluates the conductivity of solutions with varying sodium concentrations. A lithographic process was used to fabricate a Polydimethylsiloxane (PDMS) microfluidic channel through which solution was flowed. The ionization of the solution that occurs when a voltage is applied results in an effective resistance across the channel. The measured resistance therefore, reflects the ionization of the solution and the corresponding sodium concentration. The potential application of the conductometric sensor in a sweat-sensing patch requires compatibility with a microcontroller and Bluetooth module. Thus, a circuit interface was created. A voltage divider was utilized to convert the output resistance of the sensor to a voltage that could be input into a microcontroller. An AC voltage signal with a frequency of 10 kHz was used as the source voltage of the voltage divider to minimize the faradaic impedance and the double layer effect of the ionized solution. Tests have revealed that the conductometric is capable of precisely measuring the conductivity of a sodium solution. The conductometric sensor will be applied to a sweat sensing patch through future work involving studying the link between sodium concentration in sweat and an individual's dehydration level, developing a sweat-collection method, and developing a method of consideration for the other ions contained in sweat.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.