This paper presents a Bayesian approach based on integral experiments to create correlations between different isotopes which do not appear with differential data. A simple Bayesian set of equations is presented with random nuclear data, similarly to the usual methods applied with differential data. As a consequence, updated nuclear data (cross sections, [see formula in PDF], fission neutron spectra and covariance matrices) are obtained, leading to better integral results. An example for 235U and 238U is proposed taking into account the Bigten criticality benchmark.
Abstract-The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff / Λ, the effective delayed neutron fraction βeff, and the mean generation time Λ for code validation efforts. At higher detection rates, i.e. above 2×10 4 cps in the used configuration at 0.1 W, the previously employed pulse charge amplification electronics with BF3 detectors yielded erroneous results due to dead time effects. Future experimental needs call for higher sensitivity in detectors, higher detection rates or higher reactor powers, and thus a generally more versatile measurement system. We, therefore, explored detectors operated with current mode acquisition electronics to accommodate the need. We approached the matter in two ways: 1) By using the two compensated , also within 1σ agreement. The improvements to previous neutron noise measurements include shorter measurement durations that can achieve comparable statistical uncertainties and measurements at higher detection rates.
An advanced neutron detection system for highly localized measurements in nuclear reactor cores was developed and tested in the Laboratory for Reactor Physics and System Behaviour (LRS) at the École polytechnique fédérale de Lausanne (EPFL), Switzerland, in close collaboration with the Detector group of the Laboratory for Particle Physics (LTP) at the Paul Scherrer Institute (PSI), Switzerland. The miniature-size detector is based on the coupling of a ZnS:6LiF scintillator/converter screen of 1 mm2 and 0.2 mm thickness with a 10-m optical fiber, the latter being connected to a silicon photomultiplier (SiPM). In this development version, the output signal is processed via analog read-out electronics. The present work documents the characterization of a detection system prototype in the mixedradiation fields o f t he C ARROUSEL f acility a nd i ts t esting in the CROCUS zero-power reactor operated at LRS. The fibercoupled scintillator shows a linear response with the reactor power increase up to 6.5 W (i.e. around 108 cm-2s-1 total neutron flux), with a s ubsequent l oss o f l inearity d ue t o e lectronic dead time of the analog system. Nevertheless, the detector shows excellent neutron counting capabilities whether compared to other localized detection systems available at LRS, e.g. miniature fission chambers and an sCVD diamond detector.
We report on gold foil activation measurements performed along a vertical channel along the tank of the ultracold neutron source at the Paul Scherrer Institute. The activities obtained at various distances from the spallation target are in very good agreement with MCNPX simulations which take into account the detailed description of the source as built.
The EURopean Illicit TRAfficing Countermeasures Kit project is part of the 6th European Union Framework Program, and aims at developing a neutron inspection system for detecting threat materials (explosives, drugs, etc.) in cargo containers. Neutron interaction in the container produces specific gamma-rays used to determine the chemical composition of the inspected material. An associated particle sealed tube neutron generator is developed to allow precise location of the interaction point by direction and time-of-flight measurements of the neutrons tagged by alpha-particles. The EURITRACK project consists in developing: a transportable deuterium-tritium neutron generator including a position sensitive alpha detector (8×8 matrix of YAP:Ce crystals coupled to a multi-anode photomultiplier), fast neutron and gamma-ray detectors, front-end electronics to perform coincidence and spectroscopic measurements, and an integrated software which manages neutron generator and detectors positioning, data acquisition and analysis. Hardware components have been developed and tested by the consortium partners. Current status of this work and provisional performances of the system assessed by Monte Carlo calculations are presented.
The present article describes the preliminary design studies for PETALE (Programme d’Etude en Transmission de l’Acier Lourd et ses Eléments), an oncoming experimental program in the CROCUS reactor. Within the framework of the Venus-Eole-Proteus collaboration, PETALE continues the nuclear data validation efforts required for modeling GEN-III pressurized water reactors with heavy steel reflectors. The inelastic scattering cross sections at around 1 MeV of iron-56, as well as nickel and chromium isotopes, will be studied separately. The water reflector will be replaced successively by sheets of stainless steel alloy and pure metals—iron, nickel, and chromium. Data will be extracted from two sources: the measured neutron flux attenuation using adequate dosimetry and possibly fission chambers in the metal reflector and from the criticality effects of these reflectors. PETALE will also be used with nuclear data adjustment methods because, as a separated and elemental integral experiment, it allows the limiting of compensation effects in the nuclear data adjustments. A parametric study has been carried out with MCNPX for assessing the optimal configuration and the feasibility of the experiments. This study is the first step toward optimizing the global sensitivity of the experiments to the reactions in the energy range of interest, thus assessing the measurements’ target uncertainties and preparing further use of the program results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.