The technical part of these Guidelines and Recommendations, produced under the auspices of EFSUMB, provides an introduction to the physical principles and technology on which all forms of current commercially available ultrasound elastography are based. A difference in shear modulus is the common underlying physical mechanism that provides tissue contrast in all elastograms. The relationship between the alternative technologies is considered in terms of the method used to take advantage of this. The practical advantages and disadvantages associated with each of the techniques are described, and guidance is provided on optimisation of scanning technique, image display, image interpretation and some of the known image artefacts.
The clinical part of these Guidelines and Recommendations produced under the auspices of the European Federation of Societies for Ultrasound in Medicine and Biology EFSUMB assesses the clinically used applications of all forms of elastography, stressing the evidence from meta-analyses and giving practical advice for their uses and interpretation. Diffuse liver disease forms the largest section, reflecting the wide experience with transient and shear wave elastography . Then follow the breast, thyroid, gastro-intestinal tract, endoscopic elastography, the prostate and the musculo-skeletal system using strain and shear wave elastography as appropriate. The document is intended to form a reference and to guide clinical users in a practical way.
Purpose: To compare enhancement of liver parenchyma in MR imaging after injection of hepatocyte-specific contrast media.Materials and Methods: Patients (n ¼ 295) with known/ suspected focal liver lesions randomly received 0.025 mmol gadoxetic acid/kg body weight or 0.05 mmol gadobenate dimeglumine/kg body weight by means of bolus injection. MR imaging was performed before and immediately after injection, and in the delayed phase at approved time points (20 min after injection of gadoxetic acid and 40 min after injection of gadobenate dimeglumine). The relative liver enhancement for the overall population and a cirrhotic subgroup was compared in T1-weighted GRE sequences. An independent radiologist performed signal intensity measurements. Enhancement ratios were compared using confidence intervals (CIs).
Background: The introduction of automated biopsy devices and the localization of the kidney by ultrasound were aimed at optimizing efficacy and safety of the percutaneous renal biopsy procedure. We evaluated these technological advances in our renal biopsies performed in children. Methods: We sequentially used the Silverman needle (1969–1974), the TruCut needle (1974–1990), and the automated Biopty device (1990–1996). Fluoroscopy was used to localize the kidney until 1985, ultrasound examination prior to biopsy from 1985 to 1992, and direct ultrasound guidance since 1992. A total of 962 native kidney biopsies and 119 allograft biopsies were performed. Results: In the native kidney biopsies, the introduction of the Biopty device and ultrasound guidance were independently associated with fewer passes required to obtain adequate tissue and more glomeruli per specimen. The rate of biopsies yielding more than 9 glomeruli increased from 69 to 92% (p < 0.05). The number of glomeruli harvested per centimeter core length was inversely related to patient age (p < 0.01). More appropriate cortical tissue was retrieved in renal allograft biopsy specimens with the application of the new techniques. The occurrence of macroscopic hematuria (9.6%) in the native kidney biopsies was not affected by the puncture or localization technique applied, but subcapsular hematomas were documented more often with the Biopty device (42%) than with the TruCut needle (16%), probably due to improved ultrasound equipment. In the whole series 2 patients died, and 3 others required renal surgery and 4 blood transfusions. Conclusions: The automated ultrasound-guided procedure is a feasible and reliable technique for percutaneous renal biopsy in children. It gives a greater yield of diagnostic tissue without increasing the rate of clinical complications.
The objective of the study was to evaluate MRI for visualization of acromioclavicular (ac) joint structures in cadaveric shoulders, asymptomatic volunteers and symptomatic patients with trauma of the ac-joint. Three cadaveric shoulders were examined to find adequate planes and sequences for MRI. Afterwards, MR images were correlated to corresponding anatomical sections. Six asymptomatic volunteers and 13 patients were scanned in a 1.5 T Magnetom Vision with three sequences in the following planes: (1) parallel to the clavicle; (2) orthogonal to the ac joint, each time a fat-suppressed proton density-weighted + T2-sequence (TR/TE 4,000/15 ms) was performed; (3) parallel to the clavicle, T1-SE (TR/TE 817/20 ms). The parameters were: slice thickness 3 mm, field-of-view 180 mm, matrix 210x256 pixels. Standard of reference in the patients was clinical examination and conventional X-rays. Classification was by Rockwood grades I-VI. MRI allowed excellent visualization and diagnoses of ac-joint structures in volunteers and patients (n=6 normal, n=1 Rockwood I, n=5 Rockwood II, n=3 Rockwood III, n=4 Rockwood V). On MRI, in one lesion type II and III each, a lower lesion type was suspected clinically and by X-ray. In one patient additional information by MRI led to surgery. MRI allows excellent anatomical display of ac-joint structures and can give clinically relevant information on type and extension of ac-joint trauma, which may influence therapy.
Bildqualität wurde beurteilt mit 1-unzureichend, 2-schlecht, 3-mäßig, 4-gut oder 5-exzellent. Stenosen wurden eingeteilt in die Grade 1 (< 25 %), 2 (25 -< 50 %), 3 (50 -< 75 %) oder 4 (> 75 %). Mittels zweiseitigen Chi-Quadrat-Tests wurde die Korrelation in der Stenosegradbeurteilung zwischen den Modalitäten bestimmt. Mittels gewichtetem Cohen's-kappa wurde das Korrelationsmaß berechnet. Für nicht-relevante versus relevante Stenosen (Schwellenwert 50 %) wurden Sensitivität, Spezifität, PPV, NPV und Genauigkeit ermittelt. Ergebnisse: Die durchschnittliche Bildqualität für DSA/Duplex-Sonografie/CTA/MRA lag bei 3,8 ± 0,7/3,1 ± 1,0/4,4 ± 0,7/3,8 ± 0,9. Alle nicht-invasiven Modalitäten erreichten eine signifikante Korrelation in der Stenosegradbeurteilung für TC und AMS im Vergleich mit der DSA mit jeweils p < 0,001. Der gewichtete Cohen's-kappa betrug für Duplex-Sonografie/CTA/MRA für TC 0,94/ 0,93/0,74 und für AMS 0,64/ 0,91/ 0,56. Die höchste Sensitivität/Spezifität/NPV/PPV/Genauigkeit erreichte die CTA mit 100 %/95 %/85 %/ 100 %/96 % für den TC und mit na/98 %/na/100 %/ 98 % für die AMS. Schlussfolgerung: Bei bester Bildqualität erreichte die CTA das höchste Maß an Korrelation in der Stenosegradbeurteilung und bot die größte diagnostische Genauigkeit. Abstract !Objective: To prospectively analyze duplex sonography, CTA, and MRA with respect to stenosis grading of the celiac trunk (TC) and the superior mesenteric artery (SMA), with DSA as the reference. Materials and Methods: 52 subjects were enrolled (mean age: 71). The image quality was graded: 1-insufficient, 2-bad, 3-moderate, 4-good or 5-excellent. Stenosis was graded: 1 (< 25 %), 2 (25 -< 50 %), 3 (50 -75 %) or 4 (75 %). Two-sided chi-square tests were used to check for correlation of stenosis grading between modalities. The weighted Cohen's kappa was calculated to assess the strength of correlation. With a threshold of 50 % for non-relevant stenosis vs. relevant stenosis, the sensitivity, specificity, PPV, NPV, and accuracy were calculated. Results: The mean image quality was 3.8 ± 0.7, 3.1 ± 1.0, 4.4 ± 0.7, and 3.8 ± 0.9 for DSA, duplex sonography, CTA, and MRA, respectively. For both TC and SMA, stenosis grading reached a significant level of correlation between each noninvasive modality with DSA (p < 0.001, each). The weighted Cohen's kappa for duplex sonography/ CTA/MRA was 0.94/0.93/0.74, respectively, for the TC and 0.64/0.91/0.56, respectively, for the SMA. Highest sensitivity/specificity/NPV/PPV/ accuracy were found for CTA with 100 %/95 %/ 85 %/100 %/96 % for the TC and with na/98 %/na/ 100 %/98 %, respectively, for the SMA. Conclusion: CTA provided the best image quality, reached the highest level of agreement and significance in correlation in stenosis grading, and offered the best diagnostic accuracy.This document was downloaded for personal use only. Unauthorized distribution is strictly prohibited.
The addition of US to mammography vs. mammography alone resulted in a significant (P < 0.01) increase in breast cancer detection rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.