We present a technique for the measurement of temporal field autocorrelation functions of multiply scattered light with subsecond acquisition time. The setup is based on the parallel detection and autocorrelation of intensity fluctuations from statistically equivalent but independent speckles using a fiber bundle, an array of avalanche photodiodes, and a multichannel autocorrelator with variable integration times between 6.5 and 104 ms. Averaging the autocorrelation functions from the different speckles reduces the integration time in diffusing-wave spectroscopy experiments drastically, thus allowing us to resolve nonstationary scatterer dynamics with single-trial measurements. We present applications of the technique to the measurement of arterial and venous blood flow in deep tissue. We find strong deviations both of the shape and characteristic decay time of autocorrelation functions recorded at different phases of the pulsation cycle from time-averaged autocorrelation functions.
Comprehensive angiography provides insight into the diagnosis of vascular-related diseases. However, complex microvascular networks of unstable in vivo organs such as the eye require micron-scale resolution in three dimensions and a high sampling rate to access a wide area as maintaining the high resolution. Here, we introduce dual-beam-scan Doppler optical coherence angiography (OCA) as a label-free comprehensive ophthalmic angiography that satisfies theses requirements. In addition to high resolution and high imaging speed, high sensitivity to motion for detecting tiny blood flow of microvessels is achieved by detecting two time-delayed signals with scanning of two probing beams separated on a sample. We present in vivo three-dimensional imaging of the microvasculature of the posterior part of the human eye. The demonstrated results show that this technique may be used for comprehensive ophthalmic angiography to evaluate the vasculature of the posterior human eye and to diagnose variety of vascular diseases.
A high-penetration swept-source optical coherence tomography (HP-SS-OCT) system based on a 1-μm short cavity laser is developed. Doppler OCT processing is applied, along with a custom-made numerical phase stabilization algorithm; this process does not require additional calibration hardware. Thus, our phase stabilization method is simple and can be employed in a variety of SS-OCT systems. The bidirectional blood flow and vasculature in the deep choroid was successfully imaged via two Doppler modes that use different time intervals for Doppler processing. En face projection image of squared power of Doppler shift is compared to ICGA, and the utility of our method is verified.
Activity of the human visual cortex, elicited by steady-state flickering at 8 Hz, is non-invasively probed by multi-speckle diffusingwave spectroscopy (DWS). Parallel detection of the intensity fluctuations of statistically equivalent, but independent speckles allows to resolve stimulation-induced changes in the field autocorrelation of multiply scattered light of less than 2%. In a group of 9 healthy subjects we find a faster decay of the field autocorrelation function during the stimulation periods for data measured with a long-distance probe (30 mm source-receiver distance) at 2 positions over the occipital cortex (t-test: t(8) = −2.672, p = 0.028 < 0.05 for position 1, t(8) = −2.874, p = 0.021 < 0.05 for position 2). In contrast, no statistically significant change is seen when a short-distance probe (16 mm source-receiver distance) is used (t-test: t(8) = −2.043, p = 0.075 > 0.05 for position 1, t(8) = −2.146, p = 0.064 > 0.05 for position 2). The enhanced dynamics observed with DWS is positively correlated with the functional increase of blood volume in the visual cortex, while the heartbeat rate is not affected by stimulation. Our results indicate that the DWS signal from the visual cortex is governed by the regional cerebral blood flow velocity.
Abstract:We investigate the influence of a non-scattering layer on the temporal field autocorrelation function of multiple scattered light g (1) (r r r, τ) from a multilayer turbid medium such as the human head. Data from Monte Carlo simulations show very good agreement with the predictions of the correlation-diffusion equation with boundary conditions taking into account non-diffusive light transport within the non-scattering layer. Field autocorrelation functions measured at the surface of a multilayer phantom including a non-scattering layer agree well with theory and simulations when the source-receiver distance is significantly larger than the depth and the thickness of the non-scattering layer. Our results show that for sourcereceiver distances large enough to probe the dynamics in the human cortex, the cortical diffusion coefficient obtained by analyzing field autocorrelation functions neglecting the presence of the non-scattering cerebrospinal fluid layer is underestimated by about 40 % in situations representative of the human head.
Propagation of polarized light through a scattering medium has been studied with a Monte Carlo code to obtain polarized backscattered images. Studies of these backscattered patterns obtained with polarized illumination can be used as a technique to characterize the medium anisotropy factor g. First we present the different steps of the Monte Carlo simulation that describe polarized light propagation in a turbid medium. Monte Carlo is a good tool to simulate the backscattered polarized light but is time-consuming. Therefore, we consider two ways to decrease the computation time. The first way deals with angle sampling of the light direction. The second takes advantage of backscattered image symmetry to divide the simulation time by a factor of 4. By combining these two techniques we significantly decrease the code computation time.
Noise statistics of phase-resolved optical coherence tomography (OCT) imaging are complicated and involve noises of OCT, correlation of signals, and speckles. In this paper, the statistical properties of phase shift between two OCT signals that contain additive random noises and speckle noises are presented. Experimental results obtained with a scattering tissue phantom are in good agreement with theoretical predictions. The performances of the dual-beam method and conventional single-beam method are compared. As expected, phase shift noise in the case of the dual-beam-scan method is less than that for the single-beam method when the transversal sampling step is large.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.