OBJECTIVES: This study aimed to determine the brushing forces applied during in vivo toothbrushing with manual and sonic toothbrushes and to analyse the effect of these brushing forces on abrasion of sound and eroded enamel and dentin in vitro. MATERIALS AND METHODS: Brushing forces of a manual and two sonic toothbrushes (low and high frequency mode) were measured in 27 adults before and after instruction of the respective brushing technique and statistically analysed by repeated measures analysis of variance (ANOVA). In the in vitro experiment, sound and eroded enamel and dentin specimens (each subgroup n = 12) were brushed in an automatic brushing machine with the respective brushing forces using a fluoridated toothpaste slurry. Abrasion was determined by profilometry and statistically analysed by one-way ANOVA. RESULTS: Average brushing force of the manual toothbrush (1.6 ± 0.3 N) was significantly higher than for the sonic toothbrushes (0.9 ± 0.2 N), which were not significantly different from each other. Brushing force prior and after instruction of the brushing technique was not significantly different. The manual toothbrush caused highest abrasion of sound and eroded dentin, but lowest on sound enamel. No significant differences were detected on eroded enamel. CONCLUSION: Brushing forces of manual and sonic toothbrushes are different and affect their abrasive capacity. CLINICAL SIGNIFICANCE: Patients with severe tooth wear and exposed and/or eroded dentin surfaces should use sonic toothbrushes to reduce abrasion, while patients without tooth wear or with erosive lesions confining only to enamel do not benefit from sonic toothbrushes with regard to abrasion. Objectives: This study aimed to determine the brushing forces applied during in vivo toothbrushing with manual and sonic toothbrushes and to analyse the effect of these brushing forces on abrasion of sound and eroded enamel and dentin in vitro.Material and Methods: Brushing forces of a manual and two sonic toothbrushes (low and high frequency mode) were measured in 27 adults before and after instruction of the respective brushing technique and statistically analysed by repeated measures ANOVA. In the in vitro experiment, sound and eroded enamel and dentin specimens (each subgroup n=12) were brushed in an automatic brushing machine with the respective brushing forces using a fluoridated toothpaste slurry. Abrasion was determined by profilometry and statistically analysed by one-way ANOVA.Results: Average brushing force of the manual toothbrush (1.6±0.3 N) was significantly higher than for the sonic toothbrushes (0.9±0.2 N), which were not significantly different from each other. Brushing force prior and after instruction of the brushing technique was not significantly different. The manual toothbrush caused highest abrasion of sound and eroded dentin, but lowest on sound enamel. No significant differences were detected on eroded enamel.Conclusion: Brushing forces of manual and sonic toothbrushes are different and affect their abrasive capacity...
Quality of root fillings and the periapical status have improved over the last 20 years in Germany. However, there is still a need for an increase in quality of root canal treatment.
Objectives This study aimed to assess whether the emergency service of a major Swiss dental institution faced different demands (patient volume, treatment needs, dental care characteristics) during a lockdown, issued to mitigate the COVID-19 pandemic, compared with the weeks before and after. Materials and methods Data of patients receiving urgent care at a university center for dental medicine (Basel, Switzerland) during the 6-week lockdown, pre-lockdown, and post-lockdown periods were retrospectively evaluated. Statistical analysis involved tests for equal proportions and logistic regression models. The level of significance was set at α=0.05. Results The study comprised 3109 dental emergency visits in the period from February 2 to June 5, 2020. Daily caseloads increased during lockdown. Abscesses, orthodontic emergencies, and surgical follow-ups were more common during lockdown, whereas the number of dento-alveolar injuries declined (≤0.048). Urgent dental care provision involved intraoral radiographs more frequently in the pre-lockdown period compared with the following weeks (p<0.001). Among all treatments, aerosol-generating procedures dropped from 56.1% (pre-lockdown) to 21.3% during lockdown (p<0.001), while teledentistry follow-ups became more frequent (p<0.001). Patients with comorbidities sought urgent dental care less frequently during the post-lockdown period (p=0.004). Conclusions The lockdown significantly impacted the dental emergency service in terms of patients’ diagnoses, treatment needs, and the characteristics of the urgent care that was delivered. Clinical relevance Access to essential dental care must be monitored and safeguarded throughout the COVID-19 pandemic and beyond as deferred care entails risks for serious sequelae and persons with comorbidities may change their dental care-seeking behavior.
Compared with the CT, FIT led to significantly fewer and smaller enamel defects (mean volume: -0.04 mm vs -0.33 mm ) (P < 0.001), significantly less composite remained (mean volume: 0.02 mm vs 0.28 mm ) (P < 0.001), and the removal procedure with FIT was significantly quicker (mean: 162 seconds vs 268 seconds) (P < 0.001), CONCLUSIONS: FIT facilitated the removal of composite used to bond trauma splints leading to less time-consuming as well as less invasive treatment. It left fewer composite residues on enamel surfaces.
Incidental maxillary sinus findings on CBCT scans warrant thorough differential diagnosis. Frequently, they may be related to dental pathologies.
SUMMARY Aim: The aim of this study was to quantitatively compare conventional composite removal and composite removal supported by the fluorescence-aided identification technique (FIT) regarding the completeness, selectivity, and duration of the procedure in directly restored permanent posterior teeth. Methods and Materials: Two operators removed standardized direct class II composite restorations (n=32 per operator) in human tooth models under simulated clinical conditions. According to a randomized allocation scheme, removal was performed with either the conventional technique (contra-angle handpiece) or supported by FIT. The duration of each removal procedure was recorded. The completeness and selectivity were volumetrically assessed through superimposition of three-dimensional surface scans. Statistical significance was tested by examining the overlap of 95% confidence intervals (CI). Multiple comparison was performed with Tukey tests for each variable. Results: Compared with the conventional technique, composite removal with FIT was faster (329 seconds [95% confidence interval (CI): 268-390 seconds] vs 179 seconds [95% CI: 150-208 seconds]), generated less tooth substance loss (4.53 mm3 [95% CI: 3.77-5.30 mm3] vs 2.77 mm3 [95% CI: 2.11-3.43 mm3]), and left behind less composite residue (1.58 mm3 [95% CI: 1.23-1.94 mm3] vs 0.53 mm3 [95% CI: 0.39-0.67 mm3]). Conclusion: Within the limitations of this in vitro study, FIT facilitated the selective and expeditious removal of tooth-colored composites in directly restored posterior teeth.
Aim This systematic review and meta-analysis aimed to assess the diagnostic accuracy and reliability of commonly used caries detection methods for proximal caries diagnostics. Visual examination (VE), bitewing radiography (BWR), laser fluorescence (LF), and fibre-optic transillumination (FOTI) were considered in detail. Material and methods PRISMA guidelines for the reporting of systematic reviews and meta-analyses were applied. The mnemonic PIRDS (problem, index test, reference test, diagnostic and study type) concept was used to guide the literature search. Next, studies that met the inclusion criteria were stepwise selected and evaluated for their quality with a risk of bias (RoB) assessment tool. Studies with low/moderate bias and sufficient reporting were considered for meta-analysis. The pooled sensitivity (SE), specificity (SP), diagnostic odds ratio (DOR), and area under the ROC curve (AUC) were calculated. Results From 129 studies meeting the selection criteria, 31 in vitro studies and five clinical studies were finally included in the meta-analysis. The AUC values for in vitro VE amounted to 0.84 (caries detection) and 0.85 (dentin caries detection). BWR ranged in vitro from 0.55 to 0.82 (caries detection) and 0.81–0.92 (dentin caries detection). LF showed higher AUC values for overall caries detection (0.91) and dentin caries detection (0.83) than did other methods. Clinical data are limited. Conclusion The number of diagnostic studies with low/moderate RoB was found to be low and indicates a need for high-quality, well-designed caries diagnostic studies. Clinical relevance BWR and LF showed good diagnostic performance on proximal surfaces. However, because of the low number of includable clinical studies, these data should be interpreted with caution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.