Objective The purpose of this study was to analyze the reliability (interrater and intrarater) and agreement (repeatability and reproducibility) properties of tapered flow resistive loading (TFRL) measures in patients with heart failure. Methods For this cross-sectional study, participants were recruited from the cardiopulmonary rehabilitation program at the University of Brasilia from July 2015 to July 2016. All patients participated in the study, and 10 were randomly chosen for intrarater and interrater reliability testing. The 124 participants with heart failure (75% men) were 57.6 (SD = 1.81) years old and had a mean left ventricular ejection fraction of 38.9% (SD = 15%) and a peak oxygen consumption of 13.05 (SD = 5.3) mL·kg·min−1. The main outcome measures were the maximal inspiratory pressure (MIP) measured with a standard manovacuometer (SM) and the MIP and maximal dynamic inspiratory pressure (S-Index) obtained with TFRL. The S-Index reliability (interrater and intrarater) was examined by 2 evaluators, the S-Index repeatability was examined with 10 repetitions, and the reproducibility of the MIP and S-Index was measured with SM and TFRL, respectively. Results The reliability analysis revealed high S-Index interrater and intrarater reliability values (ICCs of 0.89 [95% CI = 0.58–0.98] and 0.97 [95% CI = 0.89–0.99], respectively). Repeatability analyses revealed that 8 maneuvers were required to reach the maximum S-Index in 75.81% (95% CI = 68.27–83.34) of the population. The reproducibility of TFRL measures (S-Index = 68.8 [SD = 32.8] cm H2O; MIP = 66 [SD = 32.3] cm H2O) was slightly lower than that of the SM measurement (MIP = 70.1 [SD = 35.9] cm H2O). Conclusions The TFRL device provided a reliable intrarater and interrater S-Index measure in patients with heart failure and had acceptable repeatability, requiring 8 maneuvers to produce a stable S-Index measure. The reproducibilities of the S-Index, MIP obtained with SM, and MIP obtained with TRFL were similar. Impact TRFL is a feasible method to assess both MIP and the S-index as measures of inspiratory muscle strength in patients with heart failure and can be used for inspiratory muscle training making the combined testing and training capabilities important in both clinical research and in the management of patients with heart failure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.