2020
DOI: 10.1093/ptj/pzaa165
|View full text |Cite
|
Sign up to set email alerts
|

Maximal Dynamic Inspiratory Pressure Evaluation in Heart Failure: A Comprehensive Reliability and Agreement Study

Abstract: Objective The purpose of this study was to analyze the reliability (interrater and intrarater) and agreement (repeatability and reproducibility) properties of tapered flow resistive loading (TFRL) measures in patients with heart failure. Methods For this cross-sectional study, participants were recruited from the cardiopulmonary rehabilitation program at the University of Brasilia from July 2015 to July 2016. All patients par… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…In the same way, the constant load test, where the individual ventilates with a pre-determined load until extreme tiredness, results in a time variable called TLim, in seconds [21]. This pre-determined load differs from the protocols already described, where some authors use the percentage of Pthmax of the incremental load test [23,25,27] or the percentage of MIP [34]. Despite having types of evaluation well described the protocols for global IME testing still need standardisation [25].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the same way, the constant load test, where the individual ventilates with a pre-determined load until extreme tiredness, results in a time variable called TLim, in seconds [21]. This pre-determined load differs from the protocols already described, where some authors use the percentage of Pthmax of the incremental load test [23,25,27] or the percentage of MIP [34]. Despite having types of evaluation well described the protocols for global IME testing still need standardisation [25].…”
Section: Discussionmentioning
confidence: 99%
“…Two tests to determine IME were performed using an electronic inspiratory resistor (PowerBreatheK5, IMT Technologies Ltd., Birmingham, UK) and a nose clip. Using a flow-dependent valve, this device modifies its diameter based on the generated inspiratory flow and dynamically prints load, with the airway not occluded [23]. The protocol of incremental load in steps and the protocol of constant load [22] were applied with 15 min of rest between them.…”
Section: Outcome Measuresmentioning
confidence: 99%
“…Porto Alegre, Brazil) previously calibrated with a measurement range of -300 to + 300 cmH 2 O, with a smooth plastic mouthpiece connected to the device and the use of a nose clip to avoid air escape [7]. The S-Index, which is a dynamic assessment of inspiratory pressure [15,16,24], was measured using the POWERBreathe 1 KH2 device (International, Ltd., Warwickshire, United Kingdom). For the MIP and S-Index, both inspiratory muscle tests, participants were seated and instructed to perform a maximal voluntary exhalation at residual volume, followed by a maximal inspiratory effort, according to ATS/ERS standards [8].…”
Section: Plos Onementioning
confidence: 99%