The classical "Bio Heat Transfer Equation (BHTE)" model is adapted to take into account the effects of oscillating microbubbles that occur naturally in the tissue during high-intensity focused ultrasound (HIFU) treatment. First, the Gilmore-Akulichev model is used to quantify the acoustic pressure scattered by microbubbles submitted to HIFU. Because this scattered pressure is not monochromatic, the concept of harmonic attenuation is introduced and a global attenuation coefficient is estimated for bubble-filled tissues. The first results show that this global attenuation coefficient varies significantly with respect to several parameters such as the frequency and the density of microbubbles in the medium, but also with respect to the incident acoustic pressure which thus becomes a transcendental function. Under these conditions, a layer-by-layer modeling, in the direction of propagation, is proposed to calculate the ultrasonic beam. Finally, the BHTE is solved and the HIFU-induced lesions are estimated by the calculation of the thermal dose. Using this model, it can be observed first that, when the firing power increases, the lesion develops clearly in the direction of the transducer, with a shape agreeing with in vivo experimentation. Next, it is observed that the lesion can be significantly modified in size and position, if an interface (skin or inner wall) is simulated as a zone with multiple cavitation nuclei. With a firing power increase, it is also shown how a secondary lesion can appear at the interface and how, beyond a certain threshold, this lesion develops at the main lesion expense. Finally, a better in-depth homogeneity of lesions is observed when the acoustic frequency of HIFU is increased.
The accuracy of high-intensity focused ultrasound (HIFU) lesion prediction modelling was evaluated for a truncated spherical transducer designed for prostate cancer treatment The modelling adapted the bio heat transfer equation (BHTE) to take into account the activity of cavitation bubbles generated during HIFU exposure. This modelling was used to predict the lesions produced by three different transducer geometries: fixed-focus, concentric-ring and 1.5D phased-array. Lesions were predicted for different ultrasound exposure conditions close to those used in prostate cancer treatment. Twenty-one in vitro and nine in vitro experiments were performed on pig liver to validate the accuracy of the predictions. A good match was found between the predicted and experimental lesion shapes. Lesion dimensions (maximum depth and length, area at the centre of the lesion or central surface area) were measured on experimental and predicted lesions. The central surface area was predicted by the model with a range of error of 0.15-6.5% for in vitro tests and 0.97-9% in vivo. For comparison, BHTE without bubbles had a range of error of 0.4-55.5% (in vitro) and 9-25.5% (in vivo). The model should be accurate enough to predict HIFU lesions under ultrasound exposure conditions used in prostate cancer treatment.
Atrial fibrillation (AF) is the most frequent cardiac arrhythmia. Left atrial catheter ablation is currently performed to treat this disease. Several energy sources are used, such as radio-frequency or cryotherapy. The main target of this procedure is to isolate the pulmonary veins. However, significant complications caused by the invasive procedure are described, such as stroke, tamponade, and atrioesophageal fistula, and a second intervention is often needed to avoid atrial fibrillation recurrence. For these reasons, a minimally-invasive device allowing performance of more complex treatments is still needed. High-intensity focused ultrasound (HIFU) can cause deep tissue lesions without damaging intervening tissues. Left atrial ultrasound-guided transesophageal HIFU ablation could have the potential to become a new ablation technique. The goal of this study was to design and test a minimally-invasive ultrasound-guided transesophageal HIFU probe under realistic treatment conditions. First, numerical simulations were conducted to determine the probe geometry, and to validate the feasibility of performing an AF treatment using a HIFU mini-maze (HIFUMM) procedure. Then, a prototype was manufactured and characterized. The 18-mm-diameter probe head housing contained a 3-MHz spherical truncated HIFU transducer divided into 8 rings, with a 5-MHz commercial transesophageal echocardiography (TEE) transducer integrated in the center. Finally, ex vivo experiments were performed to test the impact of the esophagus layer between the probe and the tissue to treat, and also the influence of the lungs and the vascularization on lesion formation. First results show that this prototype successfully created ex vivo transmural myocardial lesions under ultrasound guidance, while preserving intervening tissues (such as the esophagus). Ultrasound-guided transesophageal HIFU can be a good candidate for treatment of AF in the future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.