Nowadays, numerous internal bone remodelling concepts are under development, in order to estimate long-term functionality of implants by evaluating the intensity of stress-shielding effect. This effect is also analysed for the implants for direct skeletal attachment, considered as a better exoprosthesis fixation method than prosthetic sockets. Most of bone remodelling approaches are based on basic concepts, differing with certain assumptions, which may affect the accuracy of the results. This article compares commonly used internal bone remodelling concepts and evaluates the functionality of the proposed Limb Prosthesis Osseointegrated Fixation System for direct skeletal attachment of limb prosthesis in comparison with two currently available implants: the Intraosseous Transcutaneous Amputation Prosthesis and the Osseointegrated Prostheses for the Rehabilitation of Amputees. Three concepts were chosen: without and with lazy zone and with the use of quadratic formula which considers bone overloading. Therefore, three finite element models were created with identical femur implanted with each of analysed implants. The implants were loaded with loads that refer to two stages of gait cycle (heel strike and toe-off). The analysed concepts have given similar results, allowing to assume that each of them can be successfully used to estimate internal bone remodelling around analysed implants for direct skeletal attachment of limb prosthesis. The results also present higher functionality of the proposed implant for direct skeletal attachment of limb prosthesis due to a significant reduction in stress-shielding in the analysed areas around implant in comparison with the Intraosseous Transcutaneous Amputation Prosthesis and the Osseointegrated Prostheses for the Rehabilitation of Amputees. It suggests that the proposed design is a better alternative to the currently used solutions.
The purpose of the research was to evaluate the influence of selected parameters of the implants for bone anchored prostheses on possibility of conducting static load bearing exercises and stress-shielding intensity. A press-fit implant, a threaded implant, and the proposed design were compared using the finite element method. For the analyses two features were examined: diameter (19.0 – 21.0 mm) and length (75.0 – 130.0 mm). To define the possibility of conducting rehabilitation exercises the micromotion of implants while axial loading with a force up to 1000 N was examined to evaluate the changes at implant-bone interface. The stress-shielding intensity was estimated by bone mass loss over 60 months. The results suggest that, in terms of micromotion generated during rehabilitation exercises, the threaded (max. micromotion of 16.00 μm) and the proposed (max. micromotion of 45.43 μm) implants ensure low and appropriate micromotion. In the case of the press-fit solution the load values should be selected with care, as there is a risk of losing primary stabilisation. The allowed forces (that do not stimulate the organism to generate fibrous tissue) were approx. 140 N in the case of the length of 75 mm, increasing up to 560 N, while using the length of 130 mm. Moreover, obtained stress-shielding intensities suggest that the proposed implant should provide appropriate secondary stability, similar to the threaded solution, due to the low bone mass loss during long-term use (improving at the same time more bone remodelling in distal Gruen zones, by providing lower bone mass loss by approx. 13% to 20% in dependency of the length and diameter used). On this basis it can be concluded that the proposed design can be an appropriate alternative to commercially used implants.
In this article, an energy approach based on the correlation between dissipated friction energy and wear volume was used to compare wear resistances of human tooth enamel and four composite dental materials: Arkon, Ecusit, Ful-Fil, and Filtek. The results of the study showed that the wear resistance of enamel is approximately one order or more higher than the one obtained for the dental materials. The effectiveness of the approach used has also been shown. Scanning electron microscopy (SEM) examinations and chemical analysis surfaces subjected to tribological experiments made it possible to uncover substantial differences in the wear mechanisms occurring on enamel and the dental material surfaces. The wear mechanism of the dental materials used in the study is characterized mainly by chemical changes, while enamel is mainly subjected to physical transformations.
Purpose: This study attempted to establish the link between design of implants for bone-anchored prostheses and stress-shielding, affecting the stability of the bone-implant coupling using numerical approach. The objectives were to share a numerical model capable to evaluate the long-term stability of implants and to use this model to extract data sets showing how shape and material stiffness of threaded, press-fit and modular press-fit implants affect stress-shielding intensity. Methods: Three designs were considered: threaded, press-fit and modular press-fit. The effect of shape and material stiffness of each design on stress-shielding intensity was assessed using Young’s modulus (10 to 210 GPa). Furthermore, the impact of the diameter of percutaneous part (10 to 18 mm) and thickness of medullar part (5 to 1 mm) was investigated for the modular press-fit implant. Results: The threaded design generated 4% more bone mass loss at the distal femur but an overall loss of bone mass was by 5% lower to press-fit design. The influence of Young’s modulus on bone mass changes was noticeable for modular press-fit implant, depending on diameter of percutaneous or medullary part. A 20 GPa change of stiffness caused a bone mass change from 0.65% up to 2.45% and from 0.07% up to 0.32% for percutaneous parts with 18 mm and 10 mm diameter, respectively. Conclusions: Results suggested that threaded implant provides greater stability despite an increased bone loss at the distal femur. Altogether, this work provided an initial model that could be applied in subsequent studies on the long-term stability of current and upcoming implants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.