This paper presents the effect of modified halloysite nanotubes on the sustained drug release mechanisms of sodium salicylate. Acid treatment and composite polymer-halloysite modification techniques were adopted in this study. After each modification, sodium salicylate drug was loaded, and in vitro release properties were evaluated and compared with the raw unmodified halloysite nanotubes. The results obtained from SEM, TEM and FTIR analyses indicate that both acid treatment and composite formation have no effect on the tubular structure and morphology of halloysite. However, modification of the halloysite nanotubes did influence the drug release rate. In the acid treatment modification, there was an improved loading of sodium salicylate drug which resulted in the sustain release of large amount of the sodium salicylate. In the polymer/halloysite composite formation, a consistent layer of polymer was formed around the halloysite during the composite formation and thus delayed release providing sustained release of sodium salicylate drug over a longer period of time as compared to the acid treated and unmodified halloysite. The results from the invitro release were best fitted with the Higuchi and the Koresymer-Peppas models.
Due to complexities involved in experimental determination of heat transfer coefficient, diverse qualitative flow descriptions and maps have been proposed as the basis for theories and correlations. Interestingly, there have been several disagreements with the different qualitative descriptions and maps on their actual representation of heat transfer coefficient for certain regions of flow boiling processes. This study therefore seeks to experimentally investigate and compare the characteristics of heat transfer coefficient at low heat flux conditions with qualitative descriptions of heat transfer coefficient by different authors. In this study, R134a was the refrigerant used, heat fluxes from 4.6-8.5 kW/m2 and mass flux of 200-300 kg/m 2 s. The experimental heat transfer coefficient results were compared with Wojtan et al flow patterns map. In covering heat transfer coefficient over a wide range of vapor qualities, it was observed that, the qualitative descriptions proposed by different authors do not entirely validate the actual representation of heat transfer process within the experimental conditions studied. At vapor quality around zero (0), heat transfer coefficient rises to a peak and decreases to a local minimum before increasing as vapor quality increases and the flow pattern predicted for this region is slug flow. As vapor quality increased, the flow patterns observed were intermittent, annular, dryout and mist flow.
This study presents an experimental investigation of heat transfer characteristics at low heat flux conditions. The focus is to compare experimental findings with qualitative descriptions of heat transfer coefficient reported in literature. The study also compares the experimental results with 3 correlations developed based on different theories. For the experimental conditions, R134a was the refrigerant used, heat fluxes ranged from 4.6-8.5 kW/m2 and mass flux from 200-300 kg/m 2 s. The experimental heat transfer coefficient results were also compared with Wojtan et al flow patterns map to determine the flow patterns observed during the study. In covering heat transfer coefficient over a broad range of vapor qualities, the findings revealed that, the qualitative descriptions proposed by different authors do not entirely validate the actual representation of heat transfer coefficient within the experimental conditions considered. At vapor qualities around zero (0), heat transfer coefficient rises to a maximum peak and decreases to a local minimum before increasing as vapor quality increases until it reaches dry-out. The flow pattern predicted are slug flow at low vapor-quality region, intermittent flow at mid vapor quality region and annular, dry-out and mist flow at high vapor quality region. None of the flow boiling correlations considered in this study was able to accurately predict the heat transfer data within a mean absolute error (MAE) of 30%.
For the past few years, research in the field of flow boiling heat transfer has gained immense popularity for unravelling the dominant mechanism responsible for controlling heat transfer and identifying a parametric trend for understanding the characteristics of flow boiling heat transfer. This has led to several assumptions and models for predicting heat transfer during flow boiling without any known generalized mechanism. This study therefore seeks to experimentally study the characteristics of heat transfer during flow boiling over a wide range but small increase in vapor quality from a single-phase subcooled region through to a two-phase superheated vapor region. The study was performed with an R134a refrigerant in a single horizontal circular stainless-steel smooth tube that had an internal diameter of 5 mm. In this experimental study, local heat transfer coefficients and frictional pressure drop were measured for low heat fluxes of 4.6–8.5 kW/m2, mass fluxes of 200–300 kg/(m2s), vapor quality from −0.1 to 1.2 and a low constant saturation pressure of 460 kPa. Flow patterns observed during the study were recorded with a high-speed camera at 2000 fps. In covering a wide range of vapor quality, a peak of heat transfer coefficient near a vapor quality of zero and a local minimum observed in the low vapor quality region were observed, and both were sensitive to heat flux and mildly sensitive to mass flux. Generally, at low vapor quality, the heat transfer coefficient deteriorated with vapor quality and this was sensitive to heat flux but insensitive to mass flux and vapor quality, indicating nucleate boiling dominance in low vapor quality regions. In high vapor quality regions, the heat transfer coefficient was sensitive to mass flux and insensitive to heat flux. This indicates the dominance of convective boiling. In the low vapor quality regions, the flow patterns observed were slug and intermittent, while in the high vapor quality region, annular and mist flow patterns were observed. Generally, frictional pressure drop increased with increasing mass flux and vapor quality in the two-phase region.
This study presents an extensive evaluation of heat transfer characteristics, flow patterns, and pressure drop for saturation pressures ranging from 460–660 kPa in a horizontal smooth tube of 5 mm internal diameter using R134a as the working fluid. The effect of saturation pressures for mass fluxes of 150–300 kg/m2s and heat fluxes of 8.26–23.3 kW/m2 which are typical of refrigeration and air conditioning applications are also investigated. Flow patterns observed during the study are predicted with a well-known flow pattern map of Wojtan et al. The experimental results are compared with seven (7) correlations developed based on different theories to find which correlation best predicts the experimental data. The results show that, at low mass flux, increasing saturation pressure results in an increased heat transfer coefficient. This effect is more pronounced in the low vapor quality region and the dominant mechanism is nucleate boiling. At high mass flux, increasing saturation pressure leads to an insignificant increase in the heat transfer coefficient. At this high mass flux but low heat flux, the heat transfer coefficient increases with vapor quality, indicating convective boiling dominance. However, for high heat flux, the heat transfer coefficient is linear over vapor quality, indicating nucleate boiling dominance. Pressure drop is observed to decrease with increasing saturation pressure. Increasing saturation pressure increases the vapor quality at which the flow pattern transitions from intermittent flow to annular flow. The flow patterns predicted are a mixture of slug and stratified wavy and purely stratified wavy for low mass fluxes. For increased mass fluxes, the flow patterns predicted are slug, intermittent, annular, and dryout. Cooper’s model was the best predictor of the experimental data and the trend of heat transfer followed by Wattalet et al. and Liu and Winterton.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.