Chronic beryllium disease is an occupational lung disease that begins as a cell-mediated immune response to beryllium. Although respiratory and engineering controls have significantly decreased occupational beryllium exposures over the last decade, the rate of beryllium sensitization has not declined. We hypothesized that skin exposure to beryllium particles would provide an alternative route for sensitization to this metal. We employed optical scanning laser confocal microscopy and size-selected fluorospheres to demonstrate that 0.5- and 1.0- micro m particles, in conjunction with motion, as at the wrist, penetrate the stratum corneum of human skin and reach the epidermis and, occasionally, the dermis. The cutaneous immune response to chemical sensitizers is initiated in the skin, matures in the local lymph node (LN), and releases hapten-specific T cells into the peripheral blood. Topical application of beryllium to C3H mice generated beryllium-specific sensitization that was documented by peripheral blood and LN beryllium lymphocyte proliferation tests (BeLPT) and by changes in LN T-cell activation markers, increased expression of CD44, and decreased CD62L. In a sensitization-challenge treatment paradigm, epicutaneous beryllium increased murine ear thickness following chemical challenge. These data are consistent with development of a hapten-specific, cell-mediated immune response following topical application of beryllium and suggest a mechanistic link between the persistent rate of beryllium worker sensitization and skin exposure to fine and ultrafine beryllium particles.
BackgroundPhysician-performed focused ultrasonography is a rapidly growing field with numerous clinical applications. Focused ultrasound is a clinically useful tool with relevant applications across most specialties. Ultrasound technology has outpaced the education, necessitating an early introduction to the technology within the medical education system. There are many challenges to integrating ultrasound into medical education including identifying appropriately trained faculty, access to adequate resources, and appropriate integration into existing medical education curricula. As focused ultrasonography increasingly penetrates academic and community practices, access to ultrasound equipment and trained faculty is improving. However, there has remained the major challenge of determining at which level is integrating ultrasound training within the medical training paradigm most appropriate.MethodsThe Ohio State University College of Medicine has developed a novel vertical curriculum for focused ultrasonography which is concordant with the 4-year medical school curriculum. Given current evidenced-based practices, a curriculum was developed which provides medical students an exposure in focused ultrasonography. The curriculum utilizes focused ultrasonography as a teaching aid for students to gain a more thorough understanding of basic and clinical science within the medical school curriculum. The objectives of the course are to develop student understanding in indications for use, acquisition of images, interpretation of an ultrasound examination, and appropriate decision-making of ultrasound findings.ResultsPreliminary data indicate that a vertical ultrasound curriculum is a feasible and effective means of teaching focused ultrasonography. The foreseeable limitations include faculty skill level and training, initial cost of equipment, and incorporating additional information into an already saturated medical school curriculum.ConclusionsFocused ultrasonography is an evolving concept in medicine. It has been shown to improve education and patient care. The indications for and implementation of focused ultrasound is rapidly expanding in all levels of medicine. The ideal method for teaching ultrasound has yet to be established. The vertical curriculum in ultrasound at The Ohio State University College of Medicine is a novel evidenced-based training regimen at the medical school level which integrates ultrasound training into medical education and serves as a model for future integrated ultrasound curricula.
Due to ease of use and widespread applicability, Twitter and Facebook are excellent applications of "push technology" as a means to deliver educational content. This pilot project demonstrates the potential of social media to both supplement and enhance traditional educational methods.
Quantifying Quality in Ultrasound Imagingltrasound has been proven in multiple studies to improve physician clinical performance through a wide range of potential applications, including diagnostic and procedural applications. 1 With the approval of American Medical Association policy H-230.960 in 1999, the scope of practice for physicians performing ultrasound examinations increased dramatically beyond traditional indications. 2 Individual specialties have since been responsible for determining the ultrasound scope of practice within their individual field. For example, the American College of EmerDavid P. Bahner, MD, RDMS, Eric J. Adkins, MD, MSc, Rollin Nagel, PhD, David Way, MEd, Howard A. Werman, MD, Nelson A. Royall, MD Received April 14, 2011, ORIGINAL RESEARCHObjectives-Ultrasound image interpretation and education relies on obtaining a highquality ultrasound image; however, no literature exists to date attempting to define a high-quality ultrasound image. The purpose of this study was to design and perform a pilot reliability study of the Brightness Mode Quality Ultrasound Imaging Examination Technique (B-QUIET) method for ultrasound quality image assessment.Methods-A single sonologist performed a Trinity hypotensive ultrasound protocol on 3 participants of varying body types. Each participant's ultrasound examination was repeated in 4 locations; static clinic location, mobile ambulance, airplane, and helicopter. Images were reviewed by a sonographer, radiologist, and emergency medicine physician using the B-QUIET method and underwent statistical analysis using generalizability theory for reliability of the assessments using the tool.Results-The B-QUIET method showed high reliability of most subscale items. Approximately two-thirds of the reviewed images had complete inter-rater reliability on 90% of the items. There was relatively low inter-rater reliability for the Identification/ Orientation subscale items. The inter-rater reliability κ value was calculated as 0.676 overall for the method.Conclusions-The need for a standardized method to evaluate the quality of an ultrasound image is well documented. The B-QUIET method represents the first attempt to quantify the sonographer component of ultrasound images. Further reliability and validation studies of this method will be needed; however, it represents a tool for standardized ultrasound interpretation, ultrasound training, and institutional quality assessment.
Crew resource management (CRM) has the potential to improve safety culture and reduce patient safety errors across different hospitals and inherent cultures, but hospital-wide implementations have not been studied. The authors examined the impact of a systematic CRM implementation across 8 departments spanning 3 hospitals and 2 campuses. The Hospital Survey on Patient Safety Culture (HSOPS) was administered electronically to all employees before CRM implementation and about 2 years after; changes in percent positive composite scores were compared in pre-post analyses. Across all respondents, there was a statistically significant increase in composite score for 10 of the 12 HSOPS dimensions ( P < .05). These significant results persisted across the 8 departments studied and among both practitioners and staff. Consideration of score changes across dimensions reveals that the teamwork and communication dimensions of patient safety culture may be more highly influenced by CRM training than supervisor and management dimensions.
Synopsis Acute lung injury (ALI) and the acute respiratory distress syndrome (ARDS) are common indications for intensive care unit (ICU) admission and mechanical ventilation. ALI/ARDS also consumes significant health care resources and is a common cause of death in ICU patients. Obesity produces changes in respiratory system physiology that could affect outcomes for ALI/ARDS patients and their response to treatment. Additionally, the biochemical alterations seen in obese patients, such as increased inflammation and altered metabolism, could affect the risk of developing ALI/ARDS in patients with another risk factor (e.g. sepsis). The few studies which have examined the influence of obesity on the outcomes from ALI/ARDS are inconclusive. Furthermore, observed results could be biased by disparities in provided care.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.