We present an innovative satellite-based solar UV (ultraviolet) radiation dosimeter with a mobile app interface that has been validated by exploiting both ground-based measurements and an in vivo assessment of the erythemal effects on some volunteers having controlled exposure to solar radiation. The app with this satellite-based UV dosimeter also includes other related functionalities such as the provision of safe sun exposure time updated in real-time and end exposure visual/sound alert. Both validations showed that the system has a good accuracy and reliability needed for health-related applications. This app will be launched on the market by siHealth Ltd in May 2016 under the name of "HappySun" and is available for both Android and iOS devices (more info on ). Extensive R&D activities are on-going for the further improvement of the satellite-based UV dosimeter's accuracy.
With the launch of the Sentinel-5 Precursor (S-5P, lifted-off on 13 October 2017), Sentinel-4 (S-4) and Sentinel-5 (S-5)(from 2021 and 2023 onwards, respectively) operational missions of the ESA/EU Copernicus program, a massive amount of atmospheric composition data with unprecedented quality will become available from geostationary (GEO) and low Earth orbit (LEO) observations. Enhanced observational capabilities are expected to foster deeper insight than ever before on key issues relevant for air quality, stratospheric ozone, solar radiation, and climate. A major potential strength of the Sentinel observations lies in the exploitation of complementary information that originates from simultaneous and independent satellite measurements of the same air mass. The core purpose of the AURORA (Advanced Ultraviolet Radiation and Ozone Retrieval for Applications) project is to investigate this exploitation from a novel approach for merging data acquired in different spectral regions from on board the GEO and LEO platforms. A data processing chain is implemented and tested on synthetic observations. A new data algorithm combines the ultraviolet, visible and thermal infrared ozone products into S-4 and S-5(P) fused profiles. These fused products are then ingested into state-of-the-art data assimilation systems to obtain a unique ozone profile in analyses and forecasts mode. A comparative evaluation and validation of fused products assimilation versus the assimilation of the operational products will seek to demonstrate the improvements achieved by the proposed approach. This contribution provides a first general overview of the project, and discusses both the challenges of developing a technological infrastructure for implementing the AURORA concept, and the potential for applications of AURORA derived products, such as tropospheric ozone and UV surface radiation, in sectors such as air quality monitoring and health.
Background: Actinic keratosis (AK) affects one quarter of over 60 year olds in Europe with the risk of transforming into invasive squamous cell carcinoma. Daylight photodynamic therapy (dPDT) is an effective and patient preferred treatment that uses sunlight to clear AK. Currently, there is no standardised method for measuring the light received during treatment. Methods: SmartPDT® is a smartphone-based application and web-portal, developed by siHealth Ltd, enabling remote delivery of dPDT. It uses satellite imagery and computational algorithms to provide real-time determination of exposure to PpIX-effective solar radiation ("light dose"). The application also provides forecast of expected radiant exposures for 24-and 48-hs prior to the treatment period. Validation of the real-time and forecasted radiant exposure algorithms was performed against direct ground-based measurement under all weather conditions in Chilton, UK. Results: Agreement between direct ground measurements and satellite-determined radiant exposure for 2-h treatment was excellent at −0.1 % ± 5.1 % (mean ± standard deviation). There was also excellent agreement between weather forecasted radiant exposure and ground measurement, 1.8 % ± 17.7 % at 24-hs and 1.6 % ± 25.2 % at 48-hs. Relative Root Mean Square of the Error (RMSE r) demonstrated that agreement improved as time to treatment reduced (RMSE r = 22.5 % (48-hs), 11.2 % (24-hs), 5.2 % (real-time)). Conclusion: Agreement between satellite-determined, weather-forecasted and ground-measured radiant exposure was better than any existing published literature for dPDT. The SmartPDT® application and web-portal has excellent potential to assist with remote delivery of dPDT, an important factor in reducing risk in an elderly patient population during the Covid-19 pandemic.
We present here a project for the industrial development of a new magnetometer that is intended to achieve the highest performance in measuring geomagnetic field. The instrument is based on the well-known technology of optically pumped alkali vapour magnetometers. Unlike current commercial models, a diode laser replaces the traditional radio-frequency lamp as pumping source and our magnetometer uses potassium as reference atom, contrary to the more traditional cesium or rubidium. The advantages of this choice are discussed. Preliminary experimental results on a prototype show an expected accuracy better than 1 pT/Hz-1/2.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.