The temporal dynamics of the systemic arterial pressure can be monitored non-invasively from the skin of the earlobe or forehead by photoplethysmography under the provision that the active control of the microcirculatory perfusion is eliminated. Using this approach, we have been able to detect a highly stable blood pressure rhythm in the range of 0.15 Hz during psychophysical relaxation or sleep. The aim of the present study was to investigate the occurrence and behavior of blood pressure rhythms below 0.2 Hz during general anesthesia. In 30 patients (ASA groups I–II) undergoing basic surgical procedures, photoplethysmographic recordings from the earlobe were made during the whole time of anesthesia. The recorded signals were divided into segments of 200 s of duration, the temporal structure of which was analyzed by fast Fourier transform. Different characteristic patterns of rhythmical behavior were detected: (1) absence of activity below 0.2 Hz (‘low-frequency range’); (2) slow sinusoidal rhythmicity below 0.05 Hz; (3) ‘chaotic’ behavior, i.e. multiple incoherent fluctuations without stationary periods or amplitudes; (4) short-term rhythmical activity at about 0.15 Hz, and (5) long-term rhythmical activity at about 0.15 Hz. In patients sufficiently sedated to eliminate low-frequency activity, rhythmicity could sometimes be triggered by certain surgical stimuli, the response to which was suppressed by injection of opioids. The data presented strongly suggest that rhythmical perfusion patterns of the cutaneous microcirculation could serve as an indicator for the depth of anesthesia.
BACKGROUND A previous study using a parallel cooling plate cryolipolysis applicator demonstrated the efficacy of cryolipolysis for pseudogynecomastia. Although the procedure was safe and effective, treatment times were prolonged and anesthetic was needed to reduce treatment discomfort. OBJECTIVE To evaluate the safety, efficacy, and tolerability of a short cycle, reduced vacuum contoured cup cryolipolysis applicator for the treatment of pseudogynecomastia. MATERIALS AND METHODS Twelve male subjects received simultaneous bilateral treatment consisting of a 35-minute cryolipolysis cycle, followed by a short manual massage, and a second 35-minute cycle with 50% treatment area overlap in a single treatment visit. At the 6-week follow-up, a second treatment was performed with up to 2 overlapping cycles per side. Efficacy was assessed after the second treatment using transcutaneous ultrasound, standardized clinical photography, and subject surveys. RESULTS Ultrasound analysis showed a mean fat layer reduction of 5.1 6 2.3 mm (p , .001). Blinded, independent reviewers correctly identified 97% of baseline/treatment photography results. Surveys revealed 100% subject satisfaction with 91% reporting visible fat reduction and 100% stating they would recommend treatment. Transient side effects included mild intratreatment discomfort, paresthesia, and tenderness. CONCLUSION A rapid cycling, reduced vacuum cryolipolysis applicator provides rapid, safe, effective, and tolerable treatment of pseudogynecomastia.
The NYT article raises the concern of identifying quality care and choosing the "right provider"-one who successfully balances the various incentives affecting skin cancer management including appropriate usage of APPs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.