Although the upper arm has the shape of a truncated cone, cylindrical cuffs and bladders are currently used for blood pressure (BP) measurement. The aims of this study were to describe upper arm characteristics and to test the accuracy of a standard adult-size conical cuff coupled to an oscillometric device over a wide range of arm circumferences. Arm characteristics were studied in 142 subjects with arm circumferences ranging from 22 to 45 cm (study 1). In a subset of 33 subjects with the same range of arm circumferences, a rigid conical cuff with standard-size bladder (12.6Â24.0 cm) and a rigid cylindrical cuff (13.3Â24.0 cm), both coupled to a Microlife BP A100 device, were tested according to the requirements of the protocol of the European Society of Hypertension (ESH; study 2). Study 1. In all subjects, upper-arm shape was tronco-conical with slant angles ranging from 89.51 to 82.21. In a multiple linear regression analysis, only arm circumference was an independent predictor of conicity (Po0.001). Study 2. The rigid conical cuff passed all three phases of the ESH protocol for systolic and diastolic BPs. Mean device-observer BP differences obtained with the conical cuff were unrelated to arm circumference. When the rigid cylindrical cuff was used, ESH criteria were not satisfied, and the cuff overestimated systolic BPs in subjects with large arms. BP can be measured accurately with the use of a standard-size rigid conical cuff coupled to a BP A100 device for a wide range of arm circumferences.
Our results indicate that in stage 1 hypertensives followed for more than 6 years the dose-response relationship between BW loss and decrease in BP is not linear irrespective of initial BW. The BW loss >13% of initial weight did not elicit additional BP decrease.
The study was aimed at examining the effect of a short Heart Rate-Biofeedback (HR-BF) protocol on systolic (SBP) and diastolic (DBP) blood pressure levels and BP emotional reactivity. Twenty-four unmedicated outpatients with pre- and stage 1 hypertension, were randomly assigned to active treatment (BF-Training) or control (BP-Monitoring) group. Subjects in BF-Training Group underwent four BF sessions. Guided imagery of stressful events was introduced during sessions 3 and 4. Control participants self-monitored their BP at home for 4 weeks. Subjects in both groups performed an emotional Speech Test before and after the training (or monitoring) period. SBP and mean arterial pressure responses to the emotional Speech Test were significantly smaller after the BF-training than the BP-monitoring. Moreover, clinic SBP and DBP were significantly reduced by about 10 mmHg in BF-Training Group, whereas they remained unchanged in control group. Self-monitored BP decreased significantly in the active treatment group and not in control group. A short BF-training, including guided imagery of stressful events, was effective in reducing BP reactions to a psychosocial stressor. BP measured in the clinic, and self-monitored at home were also significantly reduced in the BF-Training Group. HR-BF appears to be a suitable intervention for hypertensive patients, mostly when BP increase is associated with emotional activation.
These data indicate that reactivity to public speaking is increased in stage 1 hypertension. A speech with anxiety or anger scenario elicits a greater diastolic BP reaction than tasks with neutral content.
To determine the accuracy of the EW3106 and EW3109 devices for blood pressure measurement at the upper arm developed by Panasonic. Device evaluations were performed according to the European Society of Hypertension requirements, which are based on four zones of accuracy differing from the mercury standard by 5, 10, 15 mmHg, or more. Both devices passed all three phases of the protocol for systolic blood pressure (SBP) and diastolic blood pressure (DBP). Mean blood pressure difference between the EW3106 monitor and observers was -0.9+/-5.8 mmHg for SBP and 0.1+/-4.8 mmHg for DBP. Mean differences for the EW3109 monitor were -2.1+/-6.5 mmHg and -0.3+/-4.7 mmHg, respectively. In multivariable analyses, the SBP and DBP discrepancies between both devices and observers were unrelated to age and arm circumference, and were inversely related to blood pressure level. These data show that the Panasonic EW3106 and EW 3109 monitors satisfy the recommended European Society of Hypertension accuracy levels for SBP and DBP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.