Paper-based sensors are a new alternative technology for fabricating simple, low-cost, portable and disposable analytical devices for many application areas including clinical diagnosis, food quality control and environmental monitoring. The unique properties of paper which allow passive liquid transport and compatibility with chemicals/biochemicals are the main advantages of using paper as a sensing platform. Depending on the main goal to be achieved in paper-based sensors, the fabrication methods and the analysis techniques can be tuned to fulfill the needs of the end-user. Current paper-based sensors are focused on microfluidic delivery of solution to the detection site whereas more advanced designs involve complex 3-D geometries based on the same microfluidic principles. Although paper-based sensors are very promising, they still suffer from certain limitations such as accuracy and sensitivity. However, it is anticipated that in the future, with advances in fabrication and analytical techniques, that there will be more new and innovative developments in paper-based sensors. These sensors could better meet the current objectives of a viable low-cost and portable device in addition to offering high sensitivity and selectivity, and multiple analyte discrimination. This paper is a review of recent advances in paper-based sensors and covers the following topics: existing fabrication techniques, analytical methods and application areas. Finally, the present challenges and future outlooks are discussed.
The effect of the surface chemistry of DNA recognition interfaces on DNA hybridization at a gold surface was investigated using both electrochemistry and the quartz crystal microbalance (QCM) technique. Different DNA recognition interfaces were prepared using a two-component self-assembled monolayer consisting of thiolated 20-mer probe single-stranded DNA (ss-DNA) containing either a 3'-mercaptopropyl or a 3'-mercaptohexyl linker group and an alcohol-terminated diluent layer with 2-, 6-, or 11-carbon length. The influence of the interfacial design on the hybridization efficiency, the affinity constant (Ka) describing hybridization, and the kinetics of hybridization was assessed. It was found that the further the DNA was above the surface defined by the diluent layer the higher the hybridization efficiency and Ka. The kinetics of DNA hybridization was assessed using both a QCM and an electrochemical approach to ascertain the influence of the interface on both the initial binding of target DNA to the surface and the formation of a complete duplex. These measurements showed that the length of the diluent layer has a large impact on the time taken to form a perfect duplex but no impact on the initial recognition of the target DNA by the immobilized probe DNA.
A novel chemiresistor sensor for detection of organic analytes in high-conductivity aqueous electrolyte solution is reported. The chemiresistor sensor is based on thin films of gold nanoparticles capped with a 1-hexanethiol monolayer that is inkjet printed onto a microelectrode. In order for a change in nanoparticle film resistance to be measured, the electronic conduction must preferentially occur through the nanoparticle film rather than through the high-conductivity electrolyte solution. This was achieved by miniaturizing the chemiresistor device such that the double layer capacitance of the electrodes in contact with the electrolyte solution gives rise to a significantly larger impedance compared to the nanoparticle film resistance. This system was shown to be sensitive to simple organics dissolved in an aqueous electrolyte solution. The organic analytes, dissolved in the aqueous solution, partition into the hydrophobic nanoparticle film causing the nanoparticle film to swell, resulting in an increase in the low-frequency impedance of the sensor. An increase in the impedance, at 1 Hz, of the gold nanoparticle chemiresistor on exposure to toluene, dichloromethane, and ethanol dissolved in 1 M KCl solution was demonstrated with detection limits of 0.1, 10, and 3000 ppm, respectively. Titration curves over 3 orders of magnitude could be obtained for analytes such as toluene.
The modification of electrodes with the tripeptide Gly-Gly-His for the detection of copper in water samples is described in detail. The tripeptide modified electrode was prepared by first self-assembling 3-mercaptopropionic acid (MPA) onto the gold electrode followed by covalent attachment of the tripeptide to the self-assembled monolayer using carbodiimide coupling. The electrodes were characterized using electrochemistry, a newly developed mass-spectrometry method and quantum mechanical calculations. The mass spectrometry confirmed the modification to proceed as expected with peptide bonds formed between the carboxylic acids of the MPA and the terminal amine of the peptide. Electrochemical measurements indicated that approximately half the MPA molecules in a SAM are modified with the peptide. The peptide modified electrodes exhibited high sensitivity to copper which is attributed to the stable 4N coordinate complex the peptide formed around the metal ion to give copper the preferred tetragonal coordination. The formation of a 4 coordinate complex was predicted using quantum mechanical calculation and confirmed using mass spectrometry. The adsorption of the copper to the peptide modified electrode was consistent with a Langmuir isotherm with a binding constant of (8.1 +/- 0.4) 10(10) M(-1) at 25 degrees C.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.