Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF incubation in the market, the automation of result evaluation is still in its infancy. Therefore, the EUROPattern Suite has been developed as a comprehensive automated processing and interpretation system for standardized and efficient ANA detection by HEp-2 cell-based IIF. In this study, the automated pattern recognition was compared to conventional visual interpretation in a total of 351 sera. In the discrimination of positive from negative samples, concordant results between visual and automated evaluation were obtained for 349 sera (99.4%, kappa = 0.984). The system missed out none of the 272 antibody-positive samples and identified 77 out of 79 visually negative samples (analytical sensitivity/specificity: 100%/97.5%). Moreover, 94.0% of all main antibody patterns were recognized correctly by the software. Owing to its performance characteristics, EUROPattern enables fast, objective, and economic IIF ANA analysis and has the potential to reduce intra- and interlaboratory variability.
Antinuclear autoantibodies (ANA) are highly informative biomarkers in autoimmune diagnostics. The increasing demand for effective test systems, however, has led to the development of a confusingly large variety of different platforms. One of them, the indirect immunofluorescence (IIF), is regarded as the common gold standard for ANA screening, as described in a position statement by the American College of Rheumatology in 2009. Technological solutions have been developed aimed at standardization and automation of IIF to overcome methodological limitations and subjective bias in IIF interpretation. In this review, we present the EUROPattern Suite, a system for computer-aided immunofluorescence microscopy (CAIFM) including automated acquisition of digital images and evaluation of IIF results. The system was originally designed for ANA diagnostics on human epithelial cells, but its applications have been extended with the latest system update version 1.5 to the analysis of antineutrophil cytoplasmic antibodies (ANCA) and anti-dsDNA antibodies.
Mumps is one of the vaccine-preventable childhood diseases and it has not yet been eradicated in Germany. This raises the question as to whether the available mumps vaccines are effective enough to prevent mumps and which antibody test system allows the authentic assigning of mumps-specific immunity. In an attempt to answer this question, we analysed 227 sera samples from medical students of the University Hospital Frankfurt/Main, Germany, using different test systems: indirect immune fluorescence, neutralisation assay, routine ELISA and newly developed immunoassays, which contain the mumps nucleoprotein and the wild-type strain Enders ATCC VR106, respectively. Mumps vaccination coverage of the screened collective amounted to 75.1%, which differs notably from the detected mumps-specific seropositivity rates in the literature (range 53.3% to 82.4%). In contrast, a small group of unvaccinated students had much higher seropositivity rates. Of course, assigned vaccination coverage and calculated seropositivity rates are not effective enough to interrupt the transmission of the mumps virus. The often-occurring mumps outbreaks, some in highly vaccinated populations, may not always demonstrate vaccine failure. The investigation of newly developed test systems and the occurrence of different mumps virus genotypes should also be considered.
Indirect immunofluorescence assay is the recommended gold standard to test for antinuclear antibodies (ANA), which are important biomarkers for systemic rheumatic autoimmune diseases. It is internationally accepted that indirect immunofluorescence assay ANA screening is most sensitive on human epithelial (HEp-2) cells. The cells present a multitude of antigens that display distinguishable localization patterns in interphase and mitotic cells in indirect immunofluorescence analysis. Here, we present the IFA 40: HEp-20-10 test kit (Euroimmun AG, Lübeck, Germany), which is cleared for sale on the US market by the FDA. The test has been designed for qualitative and semiquantitative screening of ANA in human sera. It uses the commonly applied 1:40 cutoff dilution and the enhanced HEp-20-10 cell line for more efficient pattern recognition and has been validated in various studies and by method comparison. The IFA 40: HEp-20-10 test fulfills the essential criteria for reliable application in autoimmune diagnostics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.