Experiments and simulations were carried out in a bench scale absorption unit; the runs were made using solutions of monoethanolamine (MEA) at 25 wt%. The gas used was a mixture of air and CO 2. Runs were conducted using three different gas flow rate, in a range between 40 to 190 NL/min, and the flow rate of MEA solution was varied to have different ratios of CO 2 :MEA, in a range between 1:2 to 1:5, for each flow rate. The results are compared with those obtained with simulations using Aspen Hysys software with a constant Murphree efficiency value of 24%, and varying it for those values calculated from experiments. In this work it was found that bench scale absorption unit has a percentage of absorption up to 99% for a CO 2 :MEA ratio of 1:4.3.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.