IMPORTANCE Exposure to ozone has been associated with cardiovascular mortality, but the underlying biological mechanisms are not yet understood.OBJECTIVE To examine the association between ozone exposure and cardiopulmonary pathophysiologic mechanisms. DESIGN, SETTING, AND PARTICIPANTSA longitudinal study involving 89 healthy adult participants living on a work campus in Changsha City, China, was conducted from December 1, 2014, to January 31, 2015. This unique quasiexperimental setting allowed for better characterization of air pollutant exposure effects because the participants spent most of their time in controlled indoor environments. Concentrations of indoor and outdoor ozone, along with the copollutants particulate matter, nitrogen dioxide, and sulfur dioxide, were monitored throughout the study period and then combined with time-activity information and filtration conditions of each residence and office to estimate 24-hour and 2-week combined indoor and outdoor mean exposure concentrations. Associations between each exposure measure and outcome measure were analyzed using single-pollutant and 2-pollutant linear mixed models controlling for ambient temperature, secondhand smoke exposure, and personal-level time-varying covariates.MAIN OUTCOMES AND MEASURES Biomarkers indicative of inflammation and oxidative stress, arterial stiffness, blood pressure, thrombotic factors, and spirometry were measured at 4 sessions. RESULTSOf the 89 participants, 25 (28%) were women and the mean (SD) age was 31.5 (7.6) years. The 24-hour ozone exposure concentrations ranged from 1.4 to 19.4 parts per billion (ppb), corresponding to outdoor concentrations ranging from 4.3 to 47.9 ppb. Within this range, in models controlling for a second copollutant and other potential confounders, a 10-ppb increase in 24-hour ozone was associated with mean increases of 36.3% (95% CI, 29.9%-43.0%) in the level of platelet activation marker soluble P-selectin, 2.8% (95% CI, 0.6%-5.1%) in diastolic blood pressure, 18.1% (95% CI, 4.5%-33.5%) in pulmonary inflammation markers fractional exhaled nitric oxide, and 31.0% (95% CI, 0.2%-71.1%) in exhaled breath condensate nitrite and nitrate as well as a −9.5% (95% CI, −17.7% to −1.4%) decrease in arterial stiffness marker augmentation index. A 10-ppb increase in 2-week ozone was associated with increases of 61.1% (95% CI, 37.8%-88.2%) in soluble P-selectin level and 126.2% (95% CI, 12.1%-356.2%) in exhaled breath condensate nitrite and nitrate level. Other measured biomarkers, including spirometry, showed no significant associations with either 24-hour ozone or 2-week ozone exposures.CONCLUSIONS AND RELEVANCE Short-term ozone exposure at levels not associated with lung function changes was associated with platelet activation and blood pressure increases, suggesting a possible mechanism by which ozone may affect cardiovascular health.
High-efficiency particulate air (HEPA) filtration in combination with an electrostatic precipitator (ESP) can be a cost-effective approach to reducing indoor particulate exposure, but ESPs produce ozone. The health effect of combined ESP-HEPA filtration has not been examined. We conducted an intervention study in 89 volunteers. At baseline, the air-handling units of offices and residences for all subjects were comprised of coarse, ESP, and HEPA filtration. During the 5-week long intervention, the subjects were split into 2 groups, 1 with just the ESP removed and the other with both the ESP and HEPA removed. Each subject was measured for cardiopulmonary risk indicators once at baseline, twice during the intervention, and once 2 weeks after baseline conditions were restored. Measured indoor and outdoor PM and ozone concentrations, coupled with time-activity data, were used to calculate exposures. Removal of HEPA filters increased 24-hour mean PM exposure by 38 (95% CI: 31, 45) μg/m . Removal of ESPs decreased 24-hour mean ozone exposure by 2.2 (2.0, 2.5) ppb. No biomarkers were significantly associated with HEPA filter removal. In contrast, ESP removal was associated with a -16.1% (-21.5%, -10.4%) change in plasma-soluble P-selectin and a -3.0% (-5.1%, -0.8%) change in systolic blood pressure, suggesting reduced cardiovascular risks.
IMPORTANCE Fine particles (particulate matter 2.5 μm [PM 2.5 ]), a ubiquitous air pollutant, can deposit in the small airways that play a vital role in asthma. It appears to be unknown whether the use of a PM 2.5 filtration device can improve small airway physiology and respiratory inflammation in children with asthma.OBJECTIVE To discover what pathophysiological changes in the small airways are associated with using a PM 2.5 -removing device in the bedrooms of children with asthma. DESIGN, SETTING, AND PARTICIPANTSChildren with mild or moderate asthma were enrolled in this double-blind, crossover study. The participants used a true filtration device and a sham filtration device in their bedrooms in a random order for 2 weeks each with a 2-week washout interval. The study was conducted in a suburb of Shanghai, China, during a low-ozone season.EXPOSURES Ozone and PM 2.5 were measured inside bedrooms and outside a window.MAIN OUTCOMES AND MEASURES Impulse oscillometry, spirometry, and fractional exhaled nitric oxide were measured at the beginning and the end of each intervention. Peak expiratory flow was measured twice daily at home. RESULTS Forty-three children (5-13 years old; 26 boys [60%]) participated. Outdoor 24-hour mean PM 2.5 concentrations were moderately high, ranging from 28.6 to 69.8 μg/m 3 (median, 53 μg/m 3 ). During true filtration, bedroom PM 2.5 concentrations were a mean (SD) of 63.4% (35.9%) lower than during sham filtration. Compared with sham filtration, true filtration was significantly associated with improved airway mechanics, reflected in a 24.4% (95% CI, 11.8%-37.1%) reduction in total airway resistance, a 43.5% (95% CI, 13.7%-73.3%) reduction in small airway resistance, a 22.2% (95% CI, 2.2%-42.2%) reduction in resonant frequency, and a 73.1% (95% CI, 0.3%-145.8%) increase in airway reactance. True filtration was also associated with significant improvements in fractional exhaled nitric oxide (a 27.6% [95% CI, 8.9%-42.4%] reduction) and peak expiratory flow (a 1.6% [95% CI, 0.8%-2.5%] increase). These improvements were significantly associated with bedroom PM 2.5 reduction. Improvements in small airway function were nonsignificant (8.4% [95% CI, −1.4% to 18.3%]) in all participants but significant (13.2% [95% CI, 1.2%-25.1%]) in participants without eosinophilic airway inflammation at baseline. No improvements were observed for forced vital capacity, forced expiratory volume during the first second, and the ratio of these in all participants or subgroups.CONCLUSIONS AND RELEVANCE Per these results, indoor PM 2.5 filtration can be a practical method to improve air flow in an asthmatic lung through improved airway mechanics and function as well as reduced inflammation. This warrants a clinical trial to confirm.
This study investigates the impacts of outdoor and indoor ozone concentrations, ESP operation and occupancy on particle number concentrations within a modern office in Changsha, China. The office's one-pass air handling system contains a mini-bag filter (MERV 12) followed by an electrostatic precipitator (ESP) and high efficiency particulate air (HEPA) filter. Over a five-week period the system was operated either without the ESP (Stage 1, first-third week) or with the ESP (Stage 2, fourth and fifth week). Ozone and particle number concentrations were measured on working days. During both stages, indoor ozone and particle number concentrations tracked the outdoor ozone concentration. When operating, the ESP produced approximately 29 mg h(-1) of ozone, increasing supply air ozone by 15 ppb and steady-state indoor ozone by about 3 ppb. Occupancy tended to decrease indoor ozone and increase particle levels. During occupancy, indoor particle levels were low (∼2600 particle/cm(3)) when the supply air ozone level was less than 18 ppb. Above this threshold, the supply air ozone concentration and indoor particle number concentration were linearly related, and ESP operation increased the average indoor particle level by about 22 000 particles/cm(3). The implications for worker exposure to both ozone and particles are discussed.
Background: Phthalates are commonly used endocrine-disrupting chemicals that are ubiquitous in the general population. Prenatal phthalate exposure may alter placental physiology and fetal development, leading to adverse perinatal and childhood health outcomes. Objective: We examined associations between prenatal phthalate exposure in the second and third trimesters and the placental transcriptome at birth, including genes and long noncoding RNAs (lncRNAs), to gain insight into potential mechanisms of action during fetal development. Methods: The ECHO PATHWAYs consortium quantified 21 urinary phthalate metabolites from 760 women enrolled in the CANDLE study (Shelby County, TN) using high-performance liquid chromatography–tandem mass spectrometry. Placental transcriptomic data were obtained using paired-end RNA sequencing. Linear models were fitted to estimate separate associations between maternal urinary phthalate metabolite concentration during the second and third trimester and placental gene expression at birth, adjusted for confounding variables. Genes were considered differentially expressed at a Benjamini-Hochberg false discovery rate (FDR) . Associations between phthalate metabolites and biological pathways were identified using self-contained gene set testing and considered significantly altered with an FDR-adjusted . Results: We observed significant associations between second-trimester phthalate metabolites mono (carboxyisooctyl) phthalate (MCIOP), mono-2-ethyl-5-carboxypentyl phthalate, and mono-2-ethyl-5-oxohexyl phthalate and 18 genes in total, including four lncRNAs. Specifically, placental expression of NEAT1 was associated with multiple phthalate metabolites. Third-trimester MCIOP and mono-isobutyl phthalate concentrations were significantly associated with placental expression of 18 genes and two genes, respectively. Expression of genes within 27 biological pathways was associated with mono-methyl phthalate, MCIOP, and monoethyl phthalate concentrations. Discussion: To our knowledge, this is the first genome-wide assessment of the relationship between the placental transcriptome at birth and prenatal phthalate exposure in a large and diverse birth cohort. We identified numerous genes and lncRNAs associated with prenatal phthalate exposure. These associations mirror findings from other epidemiological and in vitro analyses and may provide insight into biological pathways affected in utero by phthalate exposure. https://doi.org/10.1289/EHP8973
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.