This prospective, randomized, multicenter study demonstrated that quantitative clinical outcome measures following lumbar total disc replacement with the CHARITE artificial disc are at least equivalent to clinical outcomes with anterior lumbar interbody fusion. These results support earlier reports in the literature that total disc replacement with the CHARITE artificial disc is a safe and effective alternative to fusion for the surgical treatment of symptomatic disc degeneration in properly indicated patients. The CHARITE artificial disc group demonstrated statistically significant superiority in two major economic areas, a 1-day shorter hospitalization, and a lower rate of reoperations (5.4% compared with 9.1%). At 24 months, the investigational group had a significantly higher rate of satisfaction (73.7%) than the 53.1% rate of satisfaction in the control group (P = 0.0011). This prospective randomized multicenter study also demonstrated an increase in employment of 9.1% in the investigational group and 7.2% in the control group.
Introduction Surgeons' interest in image and/or robotic guidance for spinal implant placement is increasing. This technology is continually improving and may be particularly useful in patients with challenging anatomy. Only through careful clinical evaluation can its successful applications, limitations, and areas for improvement be defined. This study evaluates the outcomes of robotic-assisted screw placement in a consecutive series of 102 patients. Methods Data were recorded from technical notes and operative records created immediately following each surgery case, in which the robotic system was used to guide pedicle screw placement. All cases were performed at the same hospital by a single surgeon. The majority of patients had spinal deformity and/or previous spine surgery. Each planned screw placement was classified as: (1) successful/ accurately placed screw using robotic guidance; (2) screw malpositioned using robot; (3) use of robot aborted and screw placed manually; (4) planned screw not placed as screw deemed non essential for construct stability. Data from each case were reviewed by two independent researchers to indentify the diagnosis, number of attempted robotic guided screw placements and the outcome of the attempted placement as well as complications or reasons for non-placement. Results Robotic-guided screw placement was successfully used in 95 out of 102 patients. In those 95 patients, 949 screws (87.5 % of 1,085 planned screws) were successfully implanted. Eleven screws (1.0 %) placed using the robotic system were misplaced (all presumably due to ''skiving'' of the drill bit or trocar off the side of the facet). Robotic guidance was aborted and 110 screws (10.1 %) were manually placed, generally due to poor registration and/or technical trajectory issues. Fifteen screws (1.4 %) were not placed after intraoperative determination that the screw was not essential for construct stability. The robot was not used as planned in seven patients, one due to severe deformity, one due to very high body mass index, one due to extremely poor bone quality, one due to registration difficulty caused by previously placed loosened hardware, one due to difficulty with platform mounting and two due to device technical issues. Conclusion Of the 960 screws that were implanted using the robot, 949 (98.9 %) were successfully and accurately implanted and 11 (1.1 %) were malpositioned, despite the fact that the majority of patients had significant spinal deformities and/or previous spine surgeries. ''Tool skiving'' was thought to be the inciting issue with the misplaced screws. Intraoperative anteroposterior and oblique fluoroscopic imaging for registration is critical and was the limiting issue in four of the seven aborted cases.
Background and purpose Outcome measurement has been shown to improve performance in several fields of healthcare. This understanding has driven a growing interest in value-based healthcare, where value is defined as outcomes achieved per money spent. While low back pain (LBP) constitutes an enormous burden of disease, no universal set of metrics has yet been accepted to measure and compare outcomes. Here, we aim to define such a set.Patients and methods An international group of 22 specialists in several disciplines of spine care was assembled to review literature and select LBP outcome metrics through a 6-round modified Delphi process. The scope of the outcome set was degenerative lumbar conditions.Results Patient-reported metrics include numerical pain scales, lumbar-related function using the Oswestry disability index, health-related quality of life using the EQ-5D-3L questionnaire, and questions assessing work status and analgesic use. Specific common and serious complications are included. Recommended follow-up intervals include 6, 12, and 24 months after initiating treatment, with optional follow-up at 3 months and 5 years. Metrics for risk stratification are selected based on pre-existing tools.Interpretation The outcome measures recommended here are structured around specific etiologies of LBP, span a patient’s entire cycle of care, and allow for risk adjustment. Thus, when implemented, this set can be expected to facilitate meaningful comparisons and ultimately provide a continuous feedback loop, enabling ongoing improvements in quality of care. Much work lies ahead in implementation, revision, and validation of this set, but it is an essential first step toward establishing a community of LBP providers focused on maximizing the value of the care we deliver.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.