ObjectCervical total disc replacement (CTDR) represents a relatively novel procedure intended to address some of the shortcomings associated with anterior cervical discectomy and fusion (ACDF) by preserving motion at the treated level. This prospective, randomized, multicenter study evaluates the safety and efficacy of a new metal-on-metal CTDR implant (Kineflex|C) by comparing it with ACDF in the treatment of single-level spondylosis with radiculopathy.MethodsThe study was a prospective, randomized US FDA Investigational Device Exemption (IDE) pivotal trial conducted at 21 centers across the US. The primary clinical outcome measures included the Neck Disability Index (NDI), visual analog scale (VAS) scores, and a composite measure of clinical success. Patients were randomized to CTDR using the Kineflex|C (SpinalMotion, Inc.) cervical artificial disc or ACDF using structural allograft and an anterior plate.ResultsA total of 269 patients were enrolled and randomly assigned to either CTDR (136 patients) or to ACDF (133 patients). There were no significant differences between the CTDR and ACDF groups when comparing operative time, blood loss, length of hospital stay, or the reoperation rate at the index level. The overall success rate was significantly greater in the CTDR group (85%) compared with the ACDF group (71%) (p = 0.05). In both groups, the mean NDI scores improved significantly by 6 weeks after surgery and remained significantly improved throughout the 24-month follow-up (p < 0.0001). Similarly, the VAS pain scores improved significantly by 6 weeks and remained significantly improved through the 24-month follow-up (p < 0.0001). The range of motion (ROM) in the CTDR group decreased at 3 months but was significantly greater than the preoperative mean at 12- and 24-month follow-up. The ROM in the ACDF group was significantly reduced by 3 months and remained so throughout the follow-up. Adjacent-level degeneration was also evaluated in both groups from preoperatively to 2-year follow-up and was classified as none, mild, moderate, or severe. Preoperatively, there were no significant differences between groups when evaluating the different levels of adjacent-level degeneration. At the 2-year follow-up, there were significantly more patients in the ACDF group with severe adjacent-level radiographic changes (p < 0.0001). However, there were no significant differences between groups in adjacent-level reoperation rate (7.6% for the Kineflex|C group and 6.1% for the ACDF group).ConclusionsCervical total disc replacement allows for neural decompression and clinical results comparable to ACDF. Kineflex|C was associated with a significantly greater overall success rate than fusion while maintaining motion at the index level. Furthermore, there were significantly fewer Kineflex|C patients showing severe adjacent-level radiographic changes at the 2-year follow-up. These results from a prospective, randomized study support that Kineflex|C CTDR is a viable alternative to ACDF in select patients with cervical radiculopathy.
OBJECTThe purpose of this study was to evaluate the safety and effectiveness of 2-level total disc replacement (TDR) using a Mobi-C cervical artificial disc at 48 months' follow-up.METHODSA prospective randomized, US FDA investigational device exemption pivotal trial of the Mobi-C cervical artificial disc was conducted at 24 centers in the US. Three hundred thirty patients with degenerative disc disease were randomized and treated with cervical total disc replacement (225 patients) or the control treatment, anterior cervical discectomy and fusion (ACDF) (105 patients). Patients were followed up at regular intervals for 4 years after surgery.RESULTSAt 48 months, both groups demonstrated improvement in clinical outcome measures and a comparable safety profile. Data were available for 202 TDR patients and 89 ACDF patients in calculation of the primary endpoint. TDR patients had statistically significantly greater improvement than ACDF patients for the following outcome measures compared with baseline: Neck Disability Index scores, 12-Item Short Form Health Survey Physical Component Summary scores, patient satisfaction, and overall success. ACDF patients experienced higher subsequent surgery rates and displayed a higher rate of adjacent-segment degeneration as seen on radiographs. Overall, TDR patients maintained segmental range of motion through 48 months with no device failure.CONCLUSIONSFour-year results from this study continue to support TDR as a safe, effective, and statistically superior alternative to ACDF for the treatment of degenerative disc disease at 2 contiguous cervical levels.Clinical trial registration no.: NCT00389597 (clinicaltrials.gov)
The results of this study represent the first available Level I clinical evidence in support of cervical arthroplasty at 2 contiguous levels of the cervical spine using the Mobi-C cervical artificial disc. These results continue to support the use of cervical arthroplasty in general, but specifically demonstrate the advantages of 2-level arthroplasty over 2-level ACDF. Clinical trial registration no.: NCT00389597 (ClinicalTrials.gov).
IntroductionThere is increasing interest in the role of cervical total disc replacement (TDR) as an alternative to anterior cervical discectomy and fusion (ACDF). Multiple prospective randomized studies with minimum 2 year follow-up have shown TDR to be at least as safe and effective as ACDF in treating symptomatic degenerative disc disease at a single level. The purpose of this study was to compare outcomes of cervical TDR using the Mobi-C® with ACDF at 5-year follow-up.
BackgroundAnterior cervical discectomy and fusion (ACDF) is the gold standard for treating symptomatic cervical disc degeneration. Cervical total disc replacements (TDRs) have emerged as an alternative for some patients. The purpose of this study was to evaluate the safety and effectiveness of a new TDR device compared with ACDF for treating single-level cervical disc degeneration.MethodsThis was a prospective, randomized, controlled, multicenter Food and Drug Administration (FDA) regulated Investigational Device Exemption (IDE) study. A total of 245 patients were treated (164 TDR: 81 ACDF). The primary outcome measure was overall success based on improvement in Neck Disability Index (NDI), no subsequent surgical interventions, and no adverse events (AEs) classified as major complications.Secondary outcome measures included SF-12, visual analog scale (VAS) assessing neck and arm pain, patient satisfaction, radiographic range of motion, and adjacent level degeneration. Patients were evaluated preoperatively and postoperatively at 6 weeks, 3, 6, 12, 18, and 24 months. The hypothesis was that the TDR success rate was non-inferior to ACDF at 24 months.ResultsOverall success rates were 73.6% for TDR and 65.3% for ACDF, confirming non-inferiority (p < 0.0025). TDR demonstrated earlier improvements with significant differences in NDI scores at 6 weeks and 3 months, and VAS neck pain and SF-12 PCS scores at 6 weeks (p<0.05). Operative level range of motion in the TDR group was maintained throughout follow-up. Radiographic evidence of inferior adjacent segment degeneration was significantly greater with ACDF at 12 and 24 months (p < 0.05). AE rates were similar.ConclusionsMobi-C TDR is a safe and effective treatment for single-level disc degeneration, producing outcomes similar to ACDF with less adjacent segment degeneration. Level of Evidence: Level I.Clinical relevance: This study adds to the literature supporting cervical TDR as a viable option to ACDF in appropriately selected patients with disc degeneration.
The risk of developing adjacent segment degeneration was equivalent at median 38 months after both ACDF and TDA procedures in cervical DDD. Osteopenia and concurrent lumbar DDD significantly increase the risk of ALD.
Significant improvements were observed in pain and function. TDR patients maintained motion and had significantly lower rates of reoperation and adjacent-segment degeneration compared with ACDF. This study supports the safety and efficacy of TDR in appropriately selected patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.