Objective
To maintain the operation of a wind turbine at its maximum efficiency and for the extraction of maximum power from the wind.
Method
In this paper, at first, a novel application of fractional‐order nonlinear proportional‐integral‐derivative (FONPID) controller is proposed in the machine side converter (MSC) control loop of a 2 MW grid‐connected wind energy system. Then, the grid side converter (GSC) is controlled to ensure the unity power factor of the understudy system. To extract the maximum power from the wind, the application of the proposed controller is applied to a well‐established TSR MPPT control method, which compares optimal and actual values of rotor speed, and generated error is given to the proposed controller to vary the rotor speed accordingly. Moreover, improved MPPT performance offered by the proposed FONPID controller has also been compared to well‐established existing controllers based TSR MPPT methods. Furthermore, parameters of the proposed and existing controllers in the TSR MPPT control loop are also tuned using teaching‐learning based optimization (TLBO) and obtained performance is compared with the performance of particle swarm optimization (PSO) to show effectiveness.
Results
The generator speed offered by the proposed FONPID based TSR MPPT method effectively tracks its reference values far better than the extant controller based TSR MPPT method, whereas extant NPID has less overshoot as compared to the extant PID based TSR MPPT method.
Conclusion
To perform the effective operation of achieving MPP, q‐axis current of the stator has been controlled by the proposed FONPID based TSR MPPT method in such a style that rotor speed can be operated at its optimal value where the generator has the maximum power for given wind speed. DC‐link voltage is controlled at its rated value to guarantee the unity power factor operation using the GSC controller. FONPID based TSR MPPT method provides a better and robust MPPT operation than the PID, NPID, and FOPID controllers based TSR MPPT method. The performance has been assessed in terms of minimized fitness function value, steady‐state error, settling time, and percentage overshoot.
The mechanical power of the wind turbine has a cubic relationship with wind speed. Therefore, during high wind speed, the output power of wind turbine driven permanent magnet synchronous generator (PMSG) needs to be maintained at rated value effectively. This can be achieved by the pitch angle control of the wind turbine. In this paper, a new application of the fractionalorder nonlinear proportional-integral-derivative (FONPID) controller is pro
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.