2020
DOI: 10.1016/j.solener.2020.04.054
|View full text |Cite
|
Sign up to set email alerts
|

A Su Do Ku puzzle based shade dispersion for maximum power enhancement of partially shaded hybrid bridge-link-total-cross-tied PV array

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 70 publications
(23 citation statements)
references
References 30 publications
0
23
0
Order By: Relevance
“…The authors of [70] proposed a new reconfiguration technique to ensure a minimum deviation from the nominal operating voltage, which improves the power output, and the same can be tested on a 4 × 4 PV cell array. The authors [71] disperse the power loss of a partially shaded PV array by reconfiguring a BLTCT hybrid topology-based mostly on the SU-DO-KU puzzle, which is known as SU-DO-KU 's BLTCT reconfigured configuration. The authors of [72] proposed a new method to predict the connection of modules into a TCT PV array.…”
Section: (B) Modern Pv Array Configurationsmentioning
confidence: 99%
“…The authors of [70] proposed a new reconfiguration technique to ensure a minimum deviation from the nominal operating voltage, which improves the power output, and the same can be tested on a 4 × 4 PV cell array. The authors [71] disperse the power loss of a partially shaded PV array by reconfiguring a BLTCT hybrid topology-based mostly on the SU-DO-KU puzzle, which is known as SU-DO-KU 's BLTCT reconfigured configuration. The authors of [72] proposed a new method to predict the connection of modules into a TCT PV array.…”
Section: (B) Modern Pv Array Configurationsmentioning
confidence: 99%
“…During shading conditions, PV arrays receive different radiation levels, which leads to a variation in the row current in the PV plant. If G mn is the radiation level of PV array at row m and column n, then maximum radiation difference in each row EI m is evaluated by using Equation (12). 46…”
Section: Proposed Optimal Reconfiguration Techniquementioning
confidence: 99%
“…It is found that the GMPP location is higher side as compared to TCT, Dominance square and Su-Do-Ku (22.36%, 43.36%, and 39.31%) arrangement respectively. The authors in [29], investigated Su-Do-Ku based BL-TCT topology and observed that the power produced as 44.31W by the proposed configuration at different irradiations.…”
Section: Major Causes Of Pscs and Impact On I-v And P-v Curvesmentioning
confidence: 99%