BackgroundLiterature shows that serum selenium concentration is low in rheumatoid arthritis (RA) patients. Biochemical properties of nanoparticles (NPs) are depend in its medium dispersed. Biochemical properties could effectively alter the therapeutic potential of NPs. Phytochemicals could serve as suitable medium for dispersion of NPs. P-Coumaric acid (CA) known to have anti-inflammatory activity.Material/MethodsIn the present experiment, we investigated the anti-inflammatory effect of SeNPs dispersed in 1% CA against Complete Freund’s adjuvant induced RA. Celecoxib was used as a reference drug.ResultsSelenium NPs (SeNPs) size is maintained in 1% CA solution. We observed that supplementation with 500 μg/Kg body weight (b.w.) eNPs significantly restored the levels of thiobarbituric acid reactive substances, COX-2 activity, different antioxidant enzyme activities, and inflammatory cytokines (TNF-α, IL-1β, IL-6, and MCP-1) in RA rats. The mRNA expression of antioxidant enzymes such as MnSOD, Cu/ZnSOD, ECSOD, CAT, and GPx1 was found to be downregulated, whereas COX-2 was upregulated in RA rats; however, the mRNA expression of CAT, GPx1, and COX-2 reverted back to near normal levels in SeNPs-treated animals.ConclusionsThe therapeutic potential of SeNPs was confirmed through histological observation of angle joints in different experimental animals. Our results collectively suggest that SeNPs dispersed in CA can be an effective therapeutic agent for inflammatory disorders like acute gouty arthritis.
All study patients achieved good or excellent outcomes. No patellar tendon rupture or suture fixation failure occurred during follow-up. Suture-bridging double-row fixation is a simple and reliable method that not only improves patients' clinical symptoms, but also restores knee joint function.
Background
A mismatch between the femoral component and trochlear resection surface is observed in kinematically aligned total knee arthroplasty (KA-TKA) when conventional prostheses are employed. This mismatch is mainly manifested in the undercoverage of the lateral trochlear resection surface. The aim of the present study was to assess the relationship between the mismatch and the alignment parameters of the tibiofemoral joint.
Methods
Forty-five patients (52 knees) who underwent KA-TKA in our hospital were included. Patient-specific instrumentation was used in 16 patients (16 knees), and conventional instruments with calipers and other special tools were employed in the other 29 patients (36 knees). The widths of the exposed resection bone surface at the middle (MIDexposure) and distal (DISexposure) levels on the lateral trochlea were measured as dependent variables, whereas the hip-knee-ankle angle (HKAA), mechanical lateral distal femoral angle (mLDFA), joint line convergence angle (JLCA), medial proximal tibial angle (MPTA) and transepicondylar axis angle (TEAA) were measured as independent variables. Correlation analysis and subsequent linear regression were conducted among the dependent variables and various alignment parameters of the tibiofemoral joint.
Results
The incidence of undercoverage of the lateral trochlear resection surface was 86.5 % with MIDexposure and DISexposure values of 2.3 (0–6 mm) and 2.0 (0–5 mm), respectively. The widths of the two levels of exposed bone resection were significantly correlated with mLDFA and HKAA but were not related to TEAA.
Conclusions
The undercoverage of the trochlear resection surface in KA-TKA is mainly correlated with the degree of valgus of the distal femoral joint line. The current study suggests that this correlation should be considered in the development of KA-specific prostheses.
Kinematically aligned total knee replacements have been shown to better restore physiological kinematics than mechanical alignment and also offer good postoperative satisfaction. The purpose of this study is to evaluate the extent to which an inclined joint line in a kinematically aligned knee can alter the postoperative kinematics. A multi-body dynamic simulation was used to identify kinematic changes in the joint. To accurately compare mechanical alignment, kinematic alignment and a natural knee, a “standard” patient with neutral alignment of the lower extremities was selected for modeling from a joint database. The arthroplasty models in this study were implanted with a single conventional cruciate-retaining prosthesis. Each model was subjected to a flexion movement and the anteroposterior translation of the femoral condyles was collected for kinematic analysis. The results showed that the mechanical alignment model underwent typical paradoxical anterior translation of the femoral condyles. Incorporating an inclined joint line in the model did not prevent the paradoxical anterior translation, but a 3° varus joint line in the kinematic alignment model could reduce the peak value of this motion by about 1 mm. Moreover, the inclined joint line did not restore the motion curve back to within the range of the kinematic curve of the natural knee. The results of this study suggest that an inclined joint line, as in the kinematic alignment model, can slightly suppress paradoxical anterior translation of the femoral condyles, but cannot restore kinematic motions similar to the physiological knee. This finding implies that prostheses intended to be used for kinematic alignment should be designed to optimize knee kinematics with the intention of restoring a physiological motion curve.
ObjectiveTo compare the efficacy of the restoration of tibial component coronal alignment with a double‐check technique and the conventional surgical technique during total knee arthroplasty (TKA) in knee osteoarthritis patients, and to investigate the distribution of the medial proximal tibial angle (MPTA) after TKA.MethodsA retrospective review was performed of 151 patients (179 knees) with knee osteoarthritis undergoing primary TKA in Beijing Chaoyang Hospital, Capital Medical University from February 2013 to January 2015 to evaluate the differences in MPTA in patients undergoing the conventional TKA and those undergoing a modified TKA with a double‐check technique after the surgery. All patients were evaluated by MPTA, range of motion (ROM), Knee Society Clinical Rating System (KSS) clinical scores, and KSS functional scores. An MPTA deviation of 3° or greater was considered malalignment.ResultsA total of 130 TKA procedures in 119 patients were included in the study: 64 knees treated with conventional TKA and 66 knees treated with the double‐check technique TKA. The mean postoperative MPTA was 88.6° ± 2.2° in the conventional TKA group and 89.1° ± 1.5° in the double‐check TKA group. The mean postoperative MPTA between the two groups was not significantly different. In the conventional TKA group, 79.7% (51 knees) had a postoperative MPTA deviation within 3° and 20.3% (13 knees) had a MPTA deviation greater than 3°. In the double‐check TKA group, 93.9% (62 knees) had a postoperative MPTA deviation within 3°and 6.1% (4 knees) had a MPTA deviation greater than 3°. The postoperative MPTA deviation within 3° showed a statistically significant difference between the two groups. In the double‐check TKA group, a 21.2% (14 knees) tibial malalignment was detected after the first check and a 9.1% (6 knees) tibial malalignment was detected after the second check. The mean postoperative ROM was 118.1° ± 9.2° in the conventional TKA group and 115.7° ± 10.1° in the double‐check TKA group. The mean postoperative KSS clinical score was 89.3 ± 3.5 in the conventional TKA group and 89.0 ± 3.7 in the double‐check TKA group. The mean postoperative KSS functional score was 84.8 ± 10.0 in the conventional TKA group and 84.9 ± 9.0 in the double‐check TKA group. The mean postoperative ROM, KSS clinical scores, and KSS functional scores between the two groups were not statistically significantly different.ConclusionMalalignment of the tibial component can occur after conventional TKA, and the double‐check technique is an effective method to improve tibial component coronal alignment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.