The lens provides refractive power to the eye and is capable of altering ocular focus in response to visual demand. This capacity diminishes with age. Current biomedical technologies, which seek to design an implant lens capable of replicating the function of the biological lens, are unable as yet to provide such an implant with the requisite optical quality or ability to change the focussing power of the eye. This is because the mechanism of altering focus, termed accommodation, is not fully understood and seemingly conflicting theories require experimental support which is difficult to obtain from the living eye. This investigation presents finite element models of the eye lens based on data from human lenses aged 16 and 35 years that consider the influence of various modelling parameters, including material properties, a wide range of angles of force application and capsular thickness. Results from axisymmetric models show that the anterior and posterior zonules may have a greater impact on shape change than the equatorial zonule and that choice of capsular thickness values can influence the results from modelled simulations.
The human lens provides one-third of the ocular focussing power and is responsible for altering focus over a range of distances. This ability, termed accommodation, defines the process by which the lens alters shape to increase or decrease ocular refractive power; this is mediated by the ciliary muscle through the zonule. This ability decreases with age such that around the sixth decade of life it is lost rendering the eye unable to focus on near objects. There are two opponent theories that provide an explanation for the mechanism of accommodation; definitive support for either of these requires investigation. This work aims to elucidate how material properties can affect accommodation using Finite Element models based on interferometric measurements of refractive index. Gradients of moduli are created in three models from representative lenses, aged 16, 35 and 48 years. Different forms of zonular attachments are studied to determine which may most closely mimic the physiological form by comparing stress and displacement fields with simulated shape changes to accommodation in living lenses. The results indicate that for models to mimic accommodation in living eyes, the anterior and posterior parts of the zonule need independent force directions. Choice of material properties affects which theory of accommodation is supported.
Objective: The human visual system alters its focus by a shape change of the eye lens. The extent to which the lens can adjust ocular refractive power is dependent to a significant extent on its material properties. Yet, this fundamental link between the optics and mechanics of the lens has been relatively under investigated. This study aims to investigate this opto-mechanical link within the eye lens to gain insight into the processes of shape alteration and their respective decline with age. Methods: Finite Element models based on biological lenses were developed for five ages: 16, 35, 40, 57 and 62 years by correlating in vivo measurements of the longitudinal modulus using Brillouin scattering with in vitro X-ray interferometric measurements of refractive index and taking into account various directions of zonular force. Results: A model with radial cortical Young's moduli provides the same amount of refractive power with less change in thickness than a model with uniform cortical Young's modulus with a uniform stress distribution and no discontinuities along the cortico-nuclear boundary. The direction of zonular angles can significantly influence curvature change regardless of the modulus distribution. Conclusions: The present paper proposes a modelling approach for the human lens, coupling optical and mechanical properties, which shows the effect of parameter choice on model response. Significance: This advanced modelling approach, considering the important interplay between optical and mechanical properties, has potential for use in design of accommodating implant lenses and for investigating nonbiological causes of pathological processes in the lens (e.g. cataract).
The unique musculoskeletal structure of the human hand brings in wider dexterous capabilities to grasp and manipulate a repertoire of objects than the non-human primates. It has been widely accepted that the orientation and the position of the thumb plays an important role in this characteristic behavior. There have been numerous attempts to develop anthropomorphic robotic hands with varying levels of success. Nevertheless, manipulation ability in those hands is to be ameliorated even though they can grasp objects successfully. An appropriate model of the thumb is important to manipulate the objects against the fingers and to maintain the stability. Modeling these complex interactions about the mechanical axes of the joints and how to incorporate these joints in robotic thumbs is a challenging task. This article presents a review of the biomechanics of the human thumb and the robotic thumb designs to identify opportunities for future anthropomorphic robotic hands.
Bone augmentation is a preventative osteoporosis intervention, comprising the injection of bone cement into an osteoporotic bone. As injection of excessive amounts of bone cement may result into thermal necrosis of bone tissue or even embolism, the minimum cement volume required to achieve a predefined level of augmentation must be sought. To this end, the present paper introduces a new evolutionary optimization method, applicable to any osteoporotic bone. The method was numerically evaluated through a typical case of femoral augmentation and compared to another powerful optimization method. The results demonstrate the efficiency and low computational cost of the proposed method.
Abstract. There have been numerous attempts to develop anthropomorphic robotic hands with varying levels of dexterous capabilities. However, these robotic hands often suffer from a lack of comprehensive understanding of the musculoskeletal behavior of the human thumb with integrated foldable palm. This paper proposes a novel kinematic model to analyze the importance of thumb-palm embodiment in grasping objects. The model is validated using human demonstrations for five precision grasp types across five human subjects. The model is used to find whether there are any co-activations among the thumb joint angles and muskuloskeletal parameters of the palm. In this paper we show that there are certain pairs of joints that show stronger linear relationships in the torque space than in joint angle space. These observations provide useful design guidelines to reduce control complexity in anthropomorphic robotic thumbs.
Dielectric elastomer based generators (DEGs) offer some unique properties over energy generators based on other materials. These properties include high energy density, high efficiency over a broad range of frequencies, low compliance, the ability to produce high strain, large area, low cost films with no toxic materials and wide range environmental tolerance. As further shown in this paper, DEG materials can also exhibit a non-linear dynamic behavior, enhancing broad-band energy transfer. More specifically, dielectric elastomer (DE) energy generating synergetic structures (DIESYS) are considered as dynamic energy absorbers. Two elementary characteristic DIESYS design concepts are examined, leading to a typical antagonistic configuration for in-plane oscillations and a typical synagonistic configuration for out-of-plane oscillations. Originally, all the DE elements of the structure are assumed to be always in tension during all the phases of the harvesting cycle, conforming to the traditional concept of operation of DE structures. As shown in this paper, the traditional always-in-tension concept results in a linear dynamic system response, despite the fact that the implemented (DE) parts are considered to have been made of a non-linear (hyperelastic) material. In contrast, the proposed loose-part concept ensures the appearance of a non-linear broad-band system response, enhancing energy transfer from the environmental source.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.