A rapid and highly sensitive high-performance liquid chromatograpy method with fluorescence detection has been developed for determination of glutathione (GSH) in human plasma. A simple pre-column derivatization procedure with 7-flouro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) reagent was employed. The separation of the derivatized glutathione was performed using a mobile phase consisting of phosphate buffer (0.02 mol/L, pH 6.0)-acetonitrile (77:23, v/v) at a flow rate of 1.0 mL/min with the column temperature 2°C. The eluted derivatives were fluorometrically detected at an excitation wavelength 470 nm and an emission wavelength 530 nm. Under the optimum chromatographic conditions, the calibration curve was linear over the range of 0.1 µmol/L to 10.0 µmol/L with the correlation coefficient of 0.9988. The precision of the method was satisfactory with the intra- and inter-day coefficient of variation being 6.3%, 6.9%, respectively. This method has been used to determine glutathione concentrations in plasma samples from healthy individuals.
This article presents an improved method to detect D-glucosamine hydrochloride in health foods. A simple precolumn derivatization procedure with 7-flouro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) reagent was employed. The separation of the derivatized D-glucosamine hydrochloride (NBD-D-glucosamine hydrochloride) was performed using a mobile phase consisting of acetonitrile, potassium dihydrogen phosphate (0.01 mol/L), and trifluoroacetic acid (350:649.74:0.26, volume ratio) at a flow rate of 1.0 mL/min with the column temperature 35 °C. Under the optimum chromatographic conditions, the peak area of NBD-D-glucosamine hydrochloride compared with its absolute value of the peak area of NBD-D-glucosamine hydrochloride in a standard solution concentration range from 1.0 to 500.0 mg/L showed a good linear calibration (R = 0.9999). Recoveries, at spiked concentrations of 10.0, 40.0, and 500.0 mg/L, varied between 97.2% and 102.6% with relative standard deviations ranging from 0.4% to 1.5%. The present method provides sufficient sensitivity as reflected by the values of limit of detection (LOD) and limit of quantification (LOQ). LOD was determined from the signal-to-noise ratios (S/N) of NBD-D-glucosamine hydrochloride peak of at least 3 in the recovery test at 0.02 mg/L, and the estimated LOQ was 0.06 mg/L (S/N = 10). The proposed method was successfully applicable to detect D-glucosamine hydrochloride in health foods and drugs containing a variety of complex materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.