Periacetabular osteolysis is a potentially difficult surgical challenge, which can often drive the choice of reconstruction methods used in revision hip replacement. For smaller defects, impaction of bone grafts may be sufficient, but larger defects can require filler materials that provide structural support in addition to filling a void. This study utilized finite element analysis (FEA) to examine the state of stress in periprosthetic pelvic bone when subjected to a stair-climbing load and in the presence of two simulated defects, to show the effect of implanting a defect repair implant fabricated from Trabecular Metal. Even a small medial bone defect showed a local stress elevation of 4x compared with that seen with an acetabular implant supported by intact periacetabular bone. Local bone stress was much greater (8x the baseline level) for a defect case in which the loss of bone superior to the acetabular implant permitted significant migration. FEA results showed that a repair of the small defect with a Trabecular Metal restrictor lowered periprosthetic bone stress to a level comparable to that in the case of a primary implant. For the larger defect case, the use of a Trabecular Metal augment provides structural stabilization and helps to restore the THR head center. However, stress in the adjacent periprosthetic bone is lower than that observed in the defect-free acetabulum. In the augment case, the load path between the femoral head and the pelvis now passes through the augment as the superior rim of the acetabulum has been replaced. Contact-induced stress in the augment is similar in magnitude to that seen in the superior rim of the baseline case, although the stress pattern in the augment is noticeably different from that in intact bone.
Ultra-high molecular weight polyethylene (UHMWPE) is extensively used in orthopaedic implants, and recent constitutive modeling efforts have endeavored to rigorously capture the nonlinear, quasi-static, inelastic properties of the material. In particular, the “hybrid model” developed by Bergstrom et al. has been shown to accurately characterize the response of UHMWPE to various loading protocols including uniaxial tension to failure, cyclic uniaxial tension/compression, and small punch testing [1–2].
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.