All experts involved in the development of these guidelines have submitted declarations of interest. These have been compiled in a report and published in a supplementary document simultaneously to the guidelines. The report is also available on the ESC website www.escardio.org/Guidelines See the European Heart Journal online for supplementary data that includes background information and detailed discussion of the data that have provided the basis of the guidelines.Click here to access the corresponding ESC CardioMed chapters.
VT ablation required epicardial ablation in 121 of 913 procedures (13%), with a risk of 5% and 2% of acute and delayed major complications related to epicardial access.
PVI alone is insufficient in the treatment of persistent AF. However, additional left linear lesions increase the success rate significantly. Early AF-relapses are associated with a negative outcome after PVI alone but not following additional SM.
Aims
Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the ‘real world’ performance of the only approved PFA catheter, including acute effectiveness and safety—in particular, rare oesophageal effects and other unforeseen PFA-related complications.
Methods and results
This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7–291), full cohort included 1758 patients: mean age 61.6 years (range 19–92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9–100%). Procedure time was 65 min (38–215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each).
Conclusion
In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of ‘generic’ catheter complications (tamponade, stroke) underscores the need for improvement.
Background-Atrial tachycardias (AT) often occur after ablation of long-lasting persistent AF (CAF) and are difficult to treat conservatively. This study evaluated mechanisms and success rates of conventional mapping and catheter ablation of recurrent ATs occurring late after stepwise ablation of CAF. Methods and Results-A total of 320 patients underwent de novo ablation of CAF using a stepwise ablation approach in 2006 to 2007 at our institution. This study comprised patients who presented with recurrent ATs at their first redo procedure after initial de novo CAF ablation. All procedures were guided by conventional mapping techniques exclusively. Sixty-one patients (63Ϯ10 years, 14 women) presented with their clinical AT at their redo procedure 7.7Ϯ4.4 months after initial de novo CAF ablation. A total of 133 ATs (2.2Ϯ0.9 per patient) were mapped. Forty-four (72%) were due to reentry; 17 (28%) were focal ATs. Reentry ATs were mainly characterized as roof and perimitral flutter (43% and 34%, respectively). Focal ATs mainly originated from the great thoracic veins (pulmonary veins: 41%, coronary sinus: 23%). Forty-five (74%) patients had conduction recovery of at least 1 pulmonary vein (mean, 1.2Ϯ0.8).Overall, 124 (93%) ATs could be ablated successfully. The mean procedure duration was 181Ϯ59 minutes, with a mean fluoroscopy time of 45Ϯ21 minutes. After a mean follow-up of 21Ϯ4 months, 50 (82%) patients were free of any arrhythmia recurrences after a single redo procedure. Conclusions-Although late recurrent ATs may have complex mechanisms, catheter ablation guided exclusively by conventional techniques is highly effective with excellent acute and long-term success rates. (Circ Arrhythm Electrophysiol. 2010;3:160-169.)
Background-Currently, only anecdotal information exists on the presentation and outcome of coronary arterial injury after ablation procedures. Methods and Results-Four patients who sustained coronary artery injury of a cohort of patients undergoing 4655 consecutive ablation procedures (0.09%) are described. The patients' mean age was 45Ϯ11 years, and 1.8Ϯ0.5 prior ablation attempts had been unsuccessful. Coronary injury occurred from epicardial ventricular tachycardia ablation in 2 patients (irrigated radiofrequency ablation in one and cryoablation in the other) and ablation within the middle cardiac vein with irrigated radiofrequency in 2 patients. All involved branches of the right coronary artery. Acute occlusion presenting with ST-segment elevation immediately after ablation was recognized during the procedure in 2 cases. Occlusion failed to respond to nitroglycerin or balloon dilation, and stenting was required in both cases. Acute myocardial infarction occurred 2 weeks after epicardial ablation as a result of occlusion of a right ventricular branch of the right coronary artery giving rise to the posterior descending coronary artery in 1 patient. A moderate asymptomatic stenosis was seen on angiography after epicardial cryoablation in 1 patient. All patients recovered and remained asymptomatic from the coronary injury and arrhythmias during 37Ϯ53 months of follow-up. Conclusions-Coronary arterial injury after ablation procedures is rare. It may present acutely or several weeks after an ablation procedure. Acute occlusion appears to require coronary stenting. Unanticipated anatomic variations can predispose to coronary injury.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.