ObjectiveAlthough gastric per-oral endoscopic myotomy (G-POEM) is considered a promising technique for the management of refractory gastroparesis, high-quality evidence is limited. We prospectively investigated the efficacy and safety of G-POEM in unselected patients with refractory gastroparesis.DesignIn five tertiary centres, patients with symptomatic gastroparesis refractory to standard medical therapy and confirmed by impaired gastric emptying were included. The primary endpoint was clinical success, defined as at least one score decrease in Gastroparesis Cardinal Symptom Index (GCSI) with ≥25% decrease in two subscales, at 12 months. GCSI Score and subscales, adverse events (AEs) and 36-Item Short Form questionnaire of quality of life were evaluated at baseline and 1, 3, 6 and 12 months after G-POEM. Gastric emptying study was performed before and 3 months after the procedure.ResultsOf 80 enrolled patients, 75 patients (94%) completed 12-month follow-up. Clinical success at 12 months was 56% (95% CI, 44.8 to 66.7). GCSI Score (including subscales) improved moderately after G-POEM (p<0.05). In a regression model, a baseline GCSI Score >2.6 (OR=3.23, p=0.04) and baseline gastric retention >20% at 4 hours (OR=3.65, p=0.03) were independent predictors of clinical success at 12 months, as was early response to G-POEM at 1 month after therapy (OR 8.75, p<0.001). Mild procedure-related AEs occurred in 5 (6%) patients.ConclusionG-POEM is a safe procedure, but showed only modest overall effectiveness in the treatment of refractory gastroparesis. Further studies are required to identify the best candidates for G-POEM; unselective use of this procedure should be discouraged.Trial registration numberClinicalTrials.gov Registry NCT02732821.
The flexible endoscope is an effective and safe device for removing foreign bodies from the upper gastrointestinal tract, with a high success rate using only the polypectomy snare and the rat-toothed forceps as accessories. If foreign-body impaction lasts for more than 24 h, there is a significant increase in the incidence of complications.
NBI technology with optical filters has high sensitivity and high negative predictive value for detecting superficial esophageal SCC, and produces results comparable to those obtained with 2.5% Lugol chromoendoscopy.
BACKGROUND: One of the most feared complications with the use of cyanoacrylate for treatment of gastric varices is the occurrence of potentially life-threatening systemic embolism. Thus, endoscopists are turning towards new techniques, including endoscopic coiling, as a potentially safer and more effective treatment option. However, no studies have been performed comparing the two techniques. OBJECTIVE: This study aims to compare the safety and efficacy of endoscopic ultrasound guided coil and cyanoacrylate injection versus the conventional technique of injection of cyanoacrylate alone. DESIGN: A pilot randomized controlled trial. METHODS: Patients randomized into group I were treated with coil and cyanoacrylate, and those in group II with cyanoacrylate alone. Flow within the varix was evaluated immediately after the treatment session and one month following initial treatment. If thrombosis was confirmed, additional follow-up was performed 4 and 10 months following initial treatment. All patients underwent a thoracic computerized tomography scan after the procedure. RESULTS: A total of 32 patients, 16 in each group, were followed for an average of 9.9 months (range 1-26 months). Immediately after the procedure, 6 (37.5%) group-I patients and 8 (50%) group-II patients presented total flow reduction in the treated vessel (P=0.476). After 30 days, 11 (73.3%) group-I patients and 12 (75%) group-II patients were found to have varix thrombosis. In both groups, the majority of patients required only one single session for varix obliteration (73.3% in group I versus 80% in group II). Asymptomatic pulmonary embolism occurred in 4 (25%) group-I patients and 8 (50%) group-II patients (P=0.144). No significant difference between the groups was observed. CONCLUSION: There is no statistical difference between endoscopic ultrasound guided coils plus cyanoacrylate versus conventional cyanoacrylate technique in relation to the incidence of embolism. However, a greater tendency towards embolism was observed in the group treated using the conventional technique. Both techniques have similar efficacy in the obliteration of varices. Given the small sample size of our pilot data, our results are insufficient to prove the clinical benefit of the combined technique, and do not yet justify its use, especially in light of higher cost. Further studies with larger sample size are warranted.
-In order to draw evidence-based recommendations concerning the management of autoimmune diseases of the liver, the Brazilian Society of Hepatology has sponsored a single-topic meeting in October 18th, 2014 at São Paulo. An organizing committee comprised of seven investigators was previously elected by the Governing Board to organize the scientific agenda as well as to select twenty panelists to make a systematic review of the literature and to present topics related to the diagnosis and treatment of autoimmune hepatitis, primary sclerosing cholangitis, primary biliary cirrhosis and their overlap syndromes. After the meeting, all panelists gathered together for the discussion of the topics and the elaboration of those recommendations. The text was subsequently submitted for suggestions and approval of all members of the Brazilian Society of Hepatology through its homepage. The present paper is the final version of the reviewed manuscript organized in topics, followed by the recommendations of the Brazilian Society of Hepatology.
Background: Suction (S) is commonly used to improve cell acquisition during endoscopic ultrasoundguided fine-needle aspiration (EUS-FNA). Slow-pull (SP) sampling is another technique that might procure good quality specimens with less bloodiness. We aimed to determine if SP improves the diagnostic yield of EUS-FNA of pancreatic masses.Methods: Patients with pancreatic solid masses were randomized to four needle passes with both techniques in an alternate fashion. Sensitivity, specificity, positive, and negative predictive values were calculated. Cellularity and bloodiness of cytological samples were assessed and compared according to the technique.Results: Sensitivity, specificity, and accuracy of suction vs. SP were 95.2% vs. 92.3%; 100% vs. 100; 95.7% vs. 93%, respectively. As to the association of methods, they were 95.6, 100 and 96%, respectively. Positive predictive values for S and SP were 100%. There was no difference in diagnostic yield between S and SP (p = 0.344). Cellularity of samples obtained with SP and Suction were equivalent in both smear evaluation (p = 0.119) and cell-block (0.980). Bloodiness of SP and suction techniques were similar as well. Conclusions: S and SP techniques provide equivalent sensitivity, specificity, and accuracy. Association of methods seems to improve diagnostic yield. Suction does not increase the bloodiness of samples compared to slow-pull.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.