A large field-of-view and fast scanning of photoacoustic microscopy (PAM) relatively have been difficult to obtain due to the water-drowned structure of the system for the transmission of ultrasonic signals. Researchers have widely studied the achievement of a waterproof scanner for dynamic biological applications with a high-resolution and high signal-to-noise ratio. This Letter reports a novel, to the best of our knowledge, waterproof galvanometer scanner-based PAM system with a successfully attainable 9.0 m m × 14.5 m m scan region, amplitude scan rate of 40 kHz, and spatial resolution of 4.9 µm. The in vivo characterization of a mouse brain in intact-skull microvascular visualization demonstrated its capability in biomedical imaging and is anticipated to be an effective technique for various preclinical and clinical studies.
The primary optimization of the imaging speed of optical coherence tomography (OCT) has been keenly studied. In order to overcome the major speed limitation of spectral-domain OCT (SD-OCT), we developed an ultrahigh speed SD-OCT system, with an A-scan rate of up to 1 MHz, using the method of spacetime division multiplexing (STDM). Multi-cameras comprising a single spectrometer was implemented in the developed ultrahighspeed STDM method to eliminate the dead time of operation, whereas space-time division multiplexing was simultaneously employed to enable wide-range scanning measurements at a high speed. By successfully integrating the developed STDM method with GPU parallel processing, 8 vol/s for an image range of 250 × 250 × 2048 pixels (9 × 4.5 × 5 mm) was achieved, with an adjustable volume rate according to the required scanning speed and range. The examined STDM-OCT results of the customized optical thin film confirmed its feasibility for various fields that require rapid and wide-field scanning.
The aim of this study was to quantitatively assess the residual adhesive on orthodontic ceramic bracket-removed dental surface. In orthodontic process, ceramic bracket was repeated debonding physically, then the adhesive remained on the dental surface. The residual adhesive caused a lack of adhesive strength between dental and ceramic bracket. Since commonly used adhesive in orthodontics is translucent, residual adhesive is hard to be detected with conventional microscopes. Therefore, 1310 nm center wavelength swept-source OCT system based on laboratory customized image processing algorithm was used for the precise detection of residual adhesive on tooth surface. The algorithm separates residual adhesive from dental surface by comparing the height of adjacent B-scan images, while providing color-scaled images emphasizing the thickness information of residual adhesive. Finally, the acquired results were compared with microscopic and adhesive remnant index scoring gold standards, while the comparison confirmed the potential merits and the improvements of the proposed method over gold standards.
Optical fiber is widely used in optical coherence tomography (OCT) to propagate light precisely with low attenuation and low dispersion. However, the total optical path length within the optical fiber varies in accordance with changes of the temperature. This leads changes in the total optical travel path of the interfering signals and results in shifting of OCT image position to an unintended depth pixel value. In this paper, we presented the temperature-based automatic path length compensating method in OCT to limit the external temperature effect and control the image position in micro-scale without manual movement of optical components. By utilizing developed hardware and software of automatic temperature control system, the external temperature of optical fiber is precisely regulated that evokes thermal expansion and finally changes the physical length of fiber, which is main mechanism of temperature-based path length compensating method. The effectiveness of the presented method was verified by two-dimensional OCT images of mirror and in vivo retina. The obtained results confirmed the path length variance due to temperature change is computable and can be regulated in real-time for whole pixel range of OCT image. Therefore, the proposed temperature-based path length compensating method can be used as an alternative method to precisely control the position of OCT image, while eliminating the effect of external temperature and apply to effectively configuring compact optical systems. INDEX TERMS Optical fiber, automatic temperature control system, thermal expansion, micro position control, optical coherence tomography. I. INTRODUCTION Optical coherence tomography (OCT) is a non-destructive and high-resolution interferometric optical imaging technique that provides depth-resolved images in real-time [1], [2]. OCT has been employed in diverse applications, where The associate editor coordinating the review of this manuscript and approving it for publication was Md. Selim Habib. cross-sectional imaging is requisite; few such areas include ophthalmology [3]-[5], dermatology [6], [7], dentistry [8], [9], gastroenterology [10], [11], cardiology [12], [13] and in pulmonology studies [14], [15]. Optical fiber-based OCT systems are widely used, as they can be helpful in transferring light easily and precisely with low attenuation and low dispersion [16]-[19]. Optical fiber confines and propagates the light along with its core, which is
Mice and rats are rodent specimens commonly used in multidisciplinary research. Specifically, vasculature imaging of rodents has been widely performed in preclinical studies using various techniques, such as computed tomography, magnetic resonance imaging, and ultrasound imaging. Photoacoustic CT (PACT) is a noninvasive, nonionizing optical imaging technique derived from photoacoustic tomography and benefits from using intrinsic endogenous contrast agents to produce three-dimensional volumetric data from images. In this study, a commercial PACT device was employed to assess the cervicothoracic vasculature of mouse and rat specimens, which has rarely been examined using PACT, under two conditions with depilation and skin incision. Various blood vessels, including the common carotid artery, internal/external jugular veins, cranial vena cava, internal thoracic vein, and mammary, were identified in the acquired PACT images. The difference between the depilated and skin-incised specimens also revealed the presence of branches from certain blood vessels and specific anatomical features such as the manubrium of the sternum. This study presents detailed PACT images observing the cervicothoracic vasculature of rodent specimens and is expected to be used as a reference for various preclinical experiments on mice and rats.
Photoacoustic imaging (PAI) is a hybrid non-invasive imaging technique used to merge high optical contrast and high acoustic resolution in deep tissue. PAI has been extensively developed by utilizing its advantages that include deep imaging depth, high resolution, and label-free imaging. As a representative implementation of PAI, photoacoustic microscopy (PAM) has been used in preclinical and clinical studies for its micron-scale spatial resolution capability with high optical absorption contrast. Several handheld and portable PAM systems have been developed that improve its applicability to several fields, making it versatile. In this study, we developed a laboratory-customized, two-axis, waterproof, galvanometer scanner-based handheld PAM (WP-GVS-HH-PAM), which provides an extended field of view (14.5 × 9 mm2) for wide-range imaging. The fully waterproof handheld probe enables free movement for imaging regardless of sample shape, and volume rate and scanning region are adjustable per experimental conditions. Results of WP-GVS-HH-PAM-based phantom and in vivo imaging of mouse tissues (ear, iris, and brain) confirm the feasibility and applicability of our system as an imaging modality for various biomedical applications.
Non-invasive characterization of micro-vibrations in the tympanic membrane (TM) excited by external sound waves is considered as a promising and essential diagnosis in modern otolaryngology. To verify the possibility of measuring and discriminating the vibrating pattern of TM, here we describe a micro-vibration measurement method of latex membrane resembling the TM. The measurements are obtained with an externally generated audio stimuli of 2.0, 2.2, 2.8, 3.1 and 3.2 kHz, and their respective vibrations based tomographic, volumetric and quantitative evaluations were acquired using optical Doppler tomography (ODT). The micro oscillations and structural changes which occurred due to diverse frequencies are measured with sufficient accuracy using a highly sensitive ODT system implied phase subtraction method. The obtained results demonstrated the capability of measuring and analyzing the complex varying micro-vibration of the membrane according to implied sound frequency.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.