We characterize three nonstandard electrohydrodynamic instabilities in nematic liquid crystals composed of bent-core molecules. In addition to their shape, another important attribute of this material is that the anisotropy in the electrical conductivity changes sign as the frequency of the applied electric field changes. These instabilities do not appear to fit within the standard model for electroconvection. The first instability creates a pattern with stripes parallel to the initial director orientation, with a wavelength about equal to the separation of the cell plates. The next is the previously reported prewavy instability. The third instability is optically and dynamically identical to the prewavy instability, but is distinguished by different threshold behavior.
We report on measurements of magnetic-field induced nematic order in the bent-core liquid crystal 4-chlororesorcinol bis[4-(4-n-dodecyloxybenzoyloxy) benzoate]. Using the 31 T solenoid at the National High Magnetic Field Laboratory, we have observed, at temperatures less than 1 degrees above the clearing point, a first-order transition to the nematic phase. The critical magnetic field at which this occurs increases with temperature. We discuss these results within the context of both Maier-Saupe and Landau-de Gennes mean-field models for the nematic-isotropic transition. The implications of possible tetrahedratic order are also discussed. To our knowledge, this is the first observation of such a magnetic-field induced transition in a thermotropic liquid crystal; the reasons for which this behavior is now attainable are discussed.
Magnetic birefringence and dynamic light scattering measurements of orientational order parameter fluctuations at the isotropic-nematic phase transition of a bent-core liquid crystal reveal a pretransitional temperature dependence consistent with the standard Landau-deGennes mean field theory. However, as follows: the transition in the bent-core compound is more weakly first order (TNI-T* approximately 0.4 degrees C), the leading Landau coefficient is approximately 30 times lower, the viscosity associated with nematic order fluctuations is approximately 10 times higher, and the density change is approximately 10 times lower, than typically observed in calamitic (rod-shaped) liquid crystals. One consistent explanation for these anomalies is an optically isotropic phase composed of microscopic complexes or "clusters" of bent-core molecules.
Breast treatments are becoming increasingly complex as the use of modulated and partial breast therapies becomes more prevalent. These methods are predicated on accurate and precise positioning for treatment. However, the ability to quantify intrafraction motion has been limited by the excessive dose that would result from continuous X‐ray imaging throughout treatment. Recently, surface imaging has offered the opportunity to obtain 3D measurements of patient position throughout breast treatments without radiation exposure. Thirty free‐breathing breast patients were monitored with surface imaging for 831 monitoring sessions. Mean translations and rotations were calculated over each minute, each session, and over all sessions combined. The percentage of each session that the root mean squares (RMS) of the linear translations were outside of defined tolerances was determined for each patient. Correlations between mean translations per minute and time, and between standard deviation per minute and time, were evaluated using Pearson's r value. The mean RMS translation averaged over all patients was 2.39.15emmm±1.88.15emmm. The patients spent an average of 34%, 17%, 9%, and 5% of the monitoring time outside of 2 mm, 3 mm, 4 mm, and 5 mm RMS tolerances, respectively. The RMS values averaged over all patients were 2.71.15emmm±1.83.15emmm, 2.76±2.27, and 2.98.15emmm±2.30.15emmm over the 5th, 10th, and 15th minutes of monitoring, respectively. The RMS values (r=0.73,p=0) and standard deviations (r=0.88,p=0) over all patients showed strong significant correlations with time. We see that the majority of patients' treatment time is spent within 5 mm of the isocenter and that patient position drifts with increasing treatment time. Treatment length should be considered in the planning process. An 8 mm margin on a target volume would account for 2 SDs of motion for a treatment up to 15 minutes in length.PACS numbers: 87.53.Jw, 87.53.Kn, 87.56.Da, 87.63.L‐
These measurements suggest that the HP planning method may provide more accurate dose modeling and decreased normal lung irradiation for lung SBRT compared to the commonly used FBP and AVG planning methods when used with the AAA. The HP method does not appear to have a strong relationship with MLC modulation.
The photon optimization (PO) algorithm was recently released by Varian Medical Systems to improve volumetric modulated arc therapy (VMAT) optimization within Eclipse (Version 13.5). The purpose of this study is to compare the PO algorithm with its predecessor, progressive resolution optimizer (PRO) for lung SBRT and brain SRS treatments. A total of 30 patients were selected retrospectively. Previously, all the plans were generated with the PRO algorithm within Eclipse Version 13.6. In the new version of PO algorithm (Version 15), dynamic conformal arcs (DCA) were first conformed to the target, then VMAT inverse planning was performed to achieve the desired dose distributions. PTV coverages were forced to be identical for the same patient for a fair comparison. SBRT plan quality was assessed based on selected dose–volume parameters, including the conformity index, V 20 for lung, V 30 Gy for chest wall, and D 0.035 cc for other critical organs. SRS plan quality was evaluated based on the conformity index and normal tissue volumes encompassed by the 12 and 6 Gy isodose lines (V 12 and V 6). The modulation complexity score (MCS) was used to compare plan complexity of two algorithms. No statistically significant differences between the PRO and PO algorithms were found for any of the dosimetric parameters studied, which indicates both algorithms produce comparable plan quality. Significant improvements in the gamma passing rate (increased from 97.0% to 99.2% for SBRT and 96.1% to 98.4% for SRS), MCS (average increase of 0.15 for SBRT and 0.10 for SRS), and delivery efficiency (MU reduction of 29.8% for SBRT and 28.3% for SRS) were found for the PO algorithm. MCS showed a strong correlation with the gamma passing rate, and an inverse correlation with total MUs used. The PO algorithm offers comparable plan quality to the PRO, while minimizing MLC complexity, thereby improving the delivery efficiency and accuracy.
PET image reconstruction using a SM made from an accurately characterized PSF that accounts for r and d dependencies results in improved spatial resolution and contrast-noise relations, which may aid in lesion boundary detection for treatment planning or quantitative assessment of treatment response.
An experimental study of the heat capacity, mass density, magnetic-field-induced optical birefringence, linewidth and intensity of scattered light, and the viscosities associated with nematic order parameter fluctuations and fluid flow has been performed on an achiral bent-core liquid crystal above its clearing point temperature. The measurements reveal a transition between two optically isotropic phases that is consistent with recent theoretical predictions of a "tetrahedratic" form of orientational order.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.