Background and purpose
Studies have demonstrated the potential of online adaptive radiotherapy (oART). However, routine use has been limited due to resource demanding solutions. This study reports on experiences with oART in the pelvic region using a novel cone-beam computed tomography (CBCT)-based, artificial intelligence (AI)-driven solution.
Material and methods
Automated pre-treatment planning for thirty-nine pelvic cases (bladder, rectum, anal, and prostate), and one hundred oART simulations were conducted in a pre-clinical release of Ethos (Varian Medical Systems, Palo Alto, CA). Plan quality, AI-segmentation accuracy, oART feasibility and an integrated calculation-based quality assurance solution were evaluated. Experiences from the first five clinical oART patients (three bladder, one rectum and one sarcoma) are reported.
Results
Auto-generated pre-treatment plans demonstrated similar planning target volume (PTV) coverage and organs at risk doses, compared to institution reference. More than 75% of AI-segmentations during simulated oART required none or minor editing and the adapted plan was superior in 88% of cases. Limitations in AI-segmentation correlated to cases where AI model training was lacking. The five first treated patients complied well with the median adaptive procedure duration of 17.6 min (from CBCT acceptance to treatment delivery start). The treated bladder patients demonstrated a 42% median primary PTV reduction, indicating a 24%-30% reduction in V
45Gy
to the bowel cavity, compared to non-ART.
Conclusions
A novel commercial oART solution was demonstrated feasible for various pelvic sites. Clinically acceptable AI-segmentation and auto-planning enabled adaptation within reasonable timeslots. Possibilities for reduced PTVs observed for bladder cancer indicated potential for toxicity reductions.
The  adrenergic system plays a key role in regulating energy balance through the stimulation of both thermogenesis and lipid mobilization in brown and white adipose tissues in human and various animal models. Recent studies have suggested that a missense Trp64Arg mutation in the  3 adrenergic receptor (ADRB3) gene was involved in obesity and insulin resistance. We have investigated the effect of this mutation on obesity-related phenotypes in two cohorts: the Québec Family Study (QFS) and the Swedish Obese Subjects (SOS). In QFS, no association was found between this mutation and body mass index (BMI), body fat including abdominal visceral fat, resting metabolic rate, various diabetes and cardiovascular risk factors, and changes in body weight and body fat over a 12-yr period. With the exception of RMR ( P ϭ 0.04), no evidence of linkage was detected between the mutation and phenotypes of QFS based on sib-pair data. In SOS, the frequency of the Trp64Arg allele was not significantly different between nonobese and obese female subjects and no association was found between the mutation and body weight gain over time. These findings do not support the view that there is an association between the Trp64Arg mutation in the ADRB3 gene and obesity. ( J. Clin. Invest. 1996. 98:2086-2093.)
The all-in validation program allows a systematic approach in monitoring the different levels of RA treatments. With the systematic approach comes a better understanding of both the capabilities and the limits of the used solution. The program can be useful for implementation, but also for the validation of major upgrades.
The flexibility in radiotherapy can be improved if a patient can be moved between any one of the department's medical linear accelerators without the need to change anything in the patient's treatment plan. For this to be possible, the dosimetric characteristics of the various accelerators must be the same, or nearly the same i.e. the accelerators must be beam-matched. During a period of nine months, eight Varian iX accelerators with 6 and 15 MV photon beams and 6-18 MeV electron beams (only four of the eight) were installed at our clinic. All accelerators fulfilled the vendor-defined "fine beam-match" criteria, and a more extensive set of measurements was carried out during commissioning. The measured absorbed dose data for each accelerator were compared with the first accelerator, chosen as reference, and the TPS calculations. Two of the eight accelerators showed a larger discrepancy for the 15 MV beam not revealed by the vendor-defined acceptance criteria, whereas the other six accelerators were satisfactorily matched. The beam-matching acceptance criteria defined by the vendor are not strict enough to guarantee optimal beam-match. Deviations related to dose calculations and to beam-matched accelerators may add up. The safest and most practical way to ensure that all accelerators are within clinical acceptable accuracy is to include TPS calculations in the evaluation. Further, comparisons between measurements and calculations should be done in absolute dose terms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.